Avamar: How to address Avamar Dial Home cases
Summary: This article provides a list to other articles on how to address Avamar Dial Home cases for various symptom codes.
This article applies to
This article does not apply to
This article is not tied to any specific product.
Not all product versions are identified in this article.
Instructions
Software Events:
Hardware Events:
| Symptom: | Description | Article to address the issue: |
|---|---|---|
Symptom: 52600 |
ipmiutil: igetevent: 021f <mm/dd/yy hh:mm:ss> CRT BMC Processor #80 CATERR Proc Config Error 03 [a1 01 01] |
Contact Dell Technologies Avamar Support. |
Symptom: 52600 |
ipmiutil: igetevent: 00a5 <mm/dd/yy hh:mm:ss> CRT BMC Critical Interrupt #05 FP NMI Diag Int FP NMI 6f [00 ff ff]/code> |
Avamar: Gen4s Hardware: Symptom Code 52600 - ipmiutil: igetevent: CRT BMC Critical Interrupt |
Symptom: 52601 |
ipmiutil: igetevent: 006d <mm/dd/yy hh:mm:ss> MAJ EFI System Firmware #06 POST Err Sensor POST Code 8190 6f [a0 90 81] |
Contact Dell Technologies Avamar Support |
Symptom: 52607 |
ipmiutil: igetevent: 00fd <mm/dd/yy hh:mm:ss> MAJ BMC Fan #32 System Fan 2 Lo Crit thresh actual=1666.00 RPM, threshold=1715.00 RPM |
Avamar: Gen4s Hardware: Fan Low Threshold (Lo Crit thresh) Errors |
Symptom: 52617 |
<MRMON113> Controller ID: 0 Unexpected sense: PD = Port 0 - 3:2:2Hardware impending failure general hard drive |
Avamar: Gen4S Hardware: How to address various disk events and errors |
<MRMON113> Controller ID: 0 Unexpected sense: PD = Port 0 - 3:2:0Write protected, CDB = 0x2e 0x0 |
Avamar: Gen4s Hardware: Symptom Code 52617 - Unexpected sense: PD = Port 0 - 3:2:n. Write protectedAvamar: Gen4s Hardware: Symptom Code 52617 - Unexpected sense: PD = Port 0 - 3:2:12. Write protected (SSD) |
|
<MRMON113> Controller ID: 0 Unexpected sense: PD #012 = Port 0 - 3:2:8Internal target failure, CDB = |
Contact Dell Technologies Avamar Support |
|
<MRMON113> Controller ID: 0 Unexpected sense: PD = Port 0 - 3:2:12Information unit CRC error detected, CDB |
Avamar: Gen4S Hardware: How to address various disk events and errors |
|
<MRMON113> Controller ID: 0 Unexpected sense: PD #012 = -:-:0Write error - recommend reassignment, CDB = 0 |
Avamar: Gen4s Hardware: Symptom Code 52617 - Unexpected sense: PD = Port 0 - 3:2:12. Write protected (SSD) |
|
Symptom: 52618 |
<MRMON096> Controller ID: 0 PD Predictive failure: #012 Port 0 - 3:2:4 |
Avamar: Gen4S Hardware: How to address various disk events and errors |
Symptom: 52619 |
<MRMON015> Controller ID: 0 Fatal firmware error: Line 866 in ../../raid/2108vI2o.c Event ID:15 |
Contact Dell Technologies Avamar Support |
Symptom: 52620 |
<MRMON145> Controller ID: 0 Battery temperature is high |
Avamar - Gen4s Hardware >> Symptom Code 52620 - Controller ID: 0 Battery temperature is high |
Symptom: 52621 |
<MRMON195> Controller ID: 0 BBU disabled; changing WB logical drives to WT, Forced WB VDs are not affected |
Avamar : Gen4s Hardware >> Symptom Code 52621 - BBU disabled; changing WB logical drives to WT, Forced |
Symptom: 52622 |
<MRMON087> Controller ID: 0 Error: Port 0 - 3:2:0 ( Error 250) |
Contact Dell Technologies Avamar Support |
<MRMON268> Controller ID: 0 PD Reset: PD #012 = Port 0 - 3:2:0, Error #012 = 3, Path =#012 0 |
Avamar: Gen4S Hardware: How to address various disk events and errors |
|
Symptom: 52623 |
HARDWARE: <date> <node> <MRMON113> Controller ID: 0 Unexpected sense: PD #012 = Port 0 - 3:2:11Power on, reset, or bus device reset |
Avamar: Gen4S Hardware: How to address various disk events and errors |
Symptom: 52626 |
<MRMON267> Controller ID: 0 Command timeout on PD: PD = Port 0 - 3:2:12No addtional sense informatio |
Avamar: Gen4S Hardware: How to address various disk events and errors |
Symptom: 52627 |
ipmiutil: igetevent: 0044 01/01/05 00:00:24 MAJ BMC Voltage #de BB +3.3V Vbat Lo Crit thresh actual=0.89 V, threshold=2.14 V |
Avamar Gen4S Hardware >> Symptom Code 52601/52627 - MAJ BMC Voltage #de BB +3.3V Vbat Lo Crit thresh actual=2.05 V, threshold=2.14 V |
Symptom: 52628 |
<MRMON202> Controller ID: 0 Single-bit ECC error; critical threshold#012 exceeded: ECAR #012 = 959688528 |
Avamar: Gen4S Hardware: Single-bit ECC error; critical threshold exceeded |
Symptom: 52630 |
ipmiutil: igetevent: 009e 01/15/22 14:34:27 CRT Bios Critical Interrupt #04 PCIe Fat Sensor PCIe Fatal Surprise Link Down (00:02.0) 70 [a1 |
Avamar Gen4s Hardware >> Symptom Code 52600/52630 - CRT Bios Critical Interrupt PCIe Fat Sensor PCIe Fatal Surprise Link Down |
ipmiutil: igetevent: 0199 02/09/22 12:58:48 MAJ Bios Critical Interrupt #05 PCIe Cor Sensor PCIe Warn Receiver Error (00:01.1) 71 [a0 0 |
Avamar Gen4s Hardware >> Symptom Code 52601/52630 - MAJ Bios Critical Interrupt #05 PCIe Cor Sensor PCIe Warn Receiver Error |
|
Symptom: 52633 |
<MRMON150> Controller ID: 0 Battery has failed and cannot support data retention. Please replace the battery Event |
Gen4s Hardware >> Symptom Code 52619/52633 - Controller ID: 0 Battery has failed and cannot support data retention. Please replace the battery Event ID:150 |
Symptom: 52700 |
ipmiutil: igetevent-gen4t: 00c4 <mm/dd/yy hh:mm:ss> CRT BMC Shutdown In Progress #f4 Delayed Reb Reason Code: 0x0e 6f [81 0e ff] |
Avamar : Gen4T Hardware >> Symptom Code 52700 - HW_CRIT_BMC_ERR_G4T |
Symptom: 52701 |
ipmiutil: igetevent-gen4t: 011c <mm/dd/yy hh:mm:ss> MAJ BMC CMD Status #d2 Power Good (deasserted) 6f [00 ff ff] |
Avamar : Gen4T Hardware >> Symptom Code 52701 - HW_MAJOR_BMC_ERR_G4T |
Symptom: 52704 |
ipmiutil: igetevent-gen4t: 014c <mm/dd/yy hh:mm:ss> MAJ BMC Temperature #31 DIMM_Bank1 Hi Crit thresh actual=127.00 C, threshold=90.00 C |
Contact Dell Technologies Avamar Support |
Symptom: 52706 |
ipmiutil: igetevent-gen4t: 0158 <mm/dd/yy hh:mm:ss> MIN BMC Temperature #5f Ambient_Temp Hi Noncrit thresh actual=48.00 C, threshold=48. |
Contact Dell Technologies Avamar Support |
Symptom: 52710 |
A fan sensor detected a fan speed that has exceeded the non-critical rpm threshold within the Gen4T system. |
Contact Dell Technologies Avamar Support |
Symptom: 52712 |
ipmiutil: igetevent-gen4t: 0003 <mm/dd/yy hh:mm:ss> MAJ BMC Voltage #d8 CMOS_Voltage Lo Crit thresh actual=0.96 V, threshold=2.20 V |
Contact Dell Technologies Avamar Support |
Symptom: 52714 |
hwfaultd: DIMM N Fault |
Contact Dell Technologies Avamar Support |
Symptom: 52716 |
HARDWARE:<date> <node> hwfaultd: SLIC N Fault |
Contact Dell Technologies Avamar Support |
Symptom: 52717 |
hwfaultd: PS N Fault |
Contact Dell Technologies Avamar Support |
Symptom: 52718 |
hwfaultd: Fan N Fault |
Contact Dell Technologies Avamar Support |
Symptom: 52719 |
hwfaultd: I2C 7 Fault |
Contact Dell Technologies Avamar Support |
Symptom: 52722 |
hwfaultd: CPU Module Fault |
Contact Dell Technologies Avamar Support |
Symptom: 52723 |
hwfaultd: Expander Unrecoverable Error |
Avamar Server: Gen4T M2400 storage nodes became unresponsive and reported "hwfaultd: Expander Unrecoverable Error" & spontaneous expander reset |
Symptom: 52724 |
hwfaultd: Expander Critical Error |
Contact Dell Technologies Avamar Support |
Symptom: 52725 |
hwfaultd: Expander Non-Critical Error |
Avamar Gen4T: hwfaultd: Expander Non-Critical Error |
Symptom: 52726 |
resume_updater: libplatform failed to initialize. |
Avamar - libplatform failed to initialize |
Symptom: 52728 |
resume_updater: Chassis resume settings cannot be read. |
Avamar : Gen4T Hardware >> Symptom Code 52728 - HW_RESUPD_CHASSIS_ERR_G4T |
resume_updater: The chassis is not an Avamar system, and there is no saved resume settings. It needs to be manually set up. |
Avamar Gen4T: Error "The chassis is not an Avamar system, and there is no saved resume settings" after SP replacement |
|
resume_updater: Chassis resume settings do not match saved values. Need examination. |
Avamar - Gen4T: Chassis resume settings do not match saved values |
|
Symptom: 52750 |
Adaptec Event Monitor: [10001] :ERR: A controller has been removed from the system: controller 1 |
Contact Dell Technologies Avamar Support |
Symptom: 52751 |
Adaptec Event Monitor: [11003] :WRN: One or more logical devices contain a bad stripe: controller 1 ( PM8060-RAID #00192603647 Physical Slo |
Contact Dell Technologies Avamar Support |
Symptom: 52755 |
Adaptec Event Monitor: [12000] :WRN: Logical device is degraded: controller 1 ( PM8060-RAID #FFFFFF00 Physical Slot: 0 ), logical dev |
Avamar : Gen4T Hardware >> Symptom Code 52755 - HW_VDISK_LOST_REDUND_G4T |
Symptom: 52756 |
Adaptec Event Monitor: [12005] :ERR: Rebuild failed: controller 1 ( PM8060-RAID #BD162100991 Physical Slot: 0 ), logical device 0 (vd0 |
Contact Dell Technologies Avamar Support |
Symptom: 52759 |
Adaptec Event Monitor: [13000] :ERR: Failed drive: controller: 1 ( PM8060-RAID #FFFFFF00 Physical Slot: 0 ), channel: 0, deviceID: 11, encl |
Contact Dell Technologies Avamar Support |
Symptom: 52764 |
Adaptec Event Monitor: [13016] :WRN: Bad Block discovered: controller: 1 |
Avamar : Gen4T Hardware >> Symptom Code 52764 - HW_PHYS_DISK_BAD_BLOCK_G4T |
Symptom: 52766 |
The wearout threshold was reach on an SSD drive. |
Contact Dell Technologies Avamar Support |
Symptom: 52768 |
Adaptec Event Monitor: [14006] :WRN: Backup unit temperature exceeded the over-heat threshold: controller 1 ( PM8060-RAID #00190136942 Ph |
Contact Dell Technologies Avamar Support |
Symptom: 52769 |
Adaptec Event Monitor: [14009] :ERR: Backup unit encountered a fatal condition: controller 1 |
Contact Dell Technologies Avamar Support |
Symptom: 52805 |
hardware_monitor[55820]: MessageID:MEM9072, Created:2023-06-21T18:00:57-05:00, Severity:Critical, Message |
Avamar ADS Gen5: Event code=52804 A memory device error occurred |
Symptom: 29.AAA1.902 |
High Incoming Box - Symptom: 29.AAA1.902 |
Troubleshooting SYR HIB Service Requests (Resolution Path) |
Affected Products
Avamar, Avamar ServerArticle Properties
Article Number: 000216088
Article Type: How To
Last Modified: 21 May 2025
Version: 33
Find answers to your questions from other Dell users
Support Services