PowerEdge: Storage Components may not be displayed in iDRAC9 after Firmware Update
Summary: After upgrading iDRAC9 firmware to version 7.20.60.50 or 7.20.70.50, storage components may not be displayed or the status may appear as Unknown.
This article applies to
This article does not apply to
This article is not tied to any specific product.
Not all product versions are identified in this article.
Symptoms
The Lifecycle Controllers may log CTL138 and CTL139 errors at periodic intervals.
Cause
This issue usually occurs when external storage is connected to a Dell HBA355e adapter.
Resolution
To work around this issue, do the following.
- SSH to the iDRAC
- Run command
racadm set system.storage.LimitExternalHBATopology Enabled - Power cycle the server
Dell engineering is aware of this issue, and a permanent fix will be available in a future iDRAC firmware version.
Affected Products
Rack Servers, Tower Servers, XE Servers, XR Servers, OEM Server SolutionsArticle Properties
Article Number: 000388426
Article Type: Solution
Last Modified: 10 Nov 2025
Version: 1
Find answers to your questions from other Dell users
Support Services
Check if your device is covered by Support Services.