在軟體定義儲存 trc 中:

21/06 13:09:34.917236 0x7fed52ebbeb0:mosAsyncIO_OpenFileEx:00376: WARNING: Failed to open IO file /dev/mapper/svm_sdg with rc 3
21/06 13:09:34.917238 0x7fed52ebbeb0:file_OpenEx:00707:  Open error /dev/mapper/svm_sdg, NOT_FOUND
21/06 13:09:34.917241 0x7fed52ebbeb0:phyDev_ReadDevId:02649: failed to open file: path=/dev/mapper/svm_sdg, NOT_FOUND

安全數據儲存 cfg/partitions 檔包含一個或多個條目,其中 SDS 設備前綴為映射器/svm_sd,一個或多個不帶前綴。
以下示例顯示了這兩種類型的條目。
 

8       96 1875374424 mapper/svm_sdg
8      112 1875374424 sdh
The device errors can be cleared after the affected SDS has been restarted.

使用中的 ScaleIO 版本高於 2.0.1.3,而且 KB 000158993並不適用,儘管症狀類似。

Cause

Resolution

為避免此問題發生,請在 CloudLink 解除鎖定所有磁碟後啟動軟體定義儲存 (SDS):

  • 在關閉節點之前,請執行「/opt/emc/scaleio/sds/bin/delete_service.sh」;重新開機後,請等待所有用作 SDS 裝置的磁碟解除鎖定 (「SVM 狀態」,或 CloudLink Control Center 將會顯示),然後執行「/opt/emc/scaleio/sds/bin/create_service.sh」;或
  • 編輯「/opt/emc/extra/pre_run.sh」,並在最後一行上方插入「sleep 30」 (如果問題仍會發生,亦即 SDS 程序開始時並非所有裝置都解除鎖定,請考慮將此數字調整高 30):
...
sleep 30
echo pre_run returned...$(date) >> /var/log/svm-sds

Additional Information

這不是 ScaleIO 軟體的問題。此問題位於雲端連結 6.6 和 6.7 中,並在雲端連結 6.8 中修正。

在所有版本中將 #CCTFY25Q4 保留為關鍵字,以便進行追蹤。

Affected Products

PowerFlex Appliance, CloudLink, PowerFlex Software
Article Properties
Article Number: 000067615
Article Type: Solution
Last Modified: 24 Nov 2025
Version:  6
Find answers to your questions from other Dell users
Support Services
Check if your device is covered by Support Services.