Symptoms

此群集上没有发生其他网络更改,
节点显示为网络分区,尽管通过vmKping测试主机与其他主机可以正常连通。
  •  节点位于 vSAN 群集分区中。
  •  VSAN 运行状况页面显示 host3 与 VC 断开连接,实际上 API 调用失败 
 localcli vsan cluster get
Cluster Information:
   Enabled: true
   Current Local Time: 2019-03-03T07:40:03Z
   Local Node UUID: 5b90382f-a7d7-8dc2-4358-246e96e1013a
   Local Node Type: NORMAL
   Local Node State: MASTER
   Local Node Health State: HEALTHY
   Sub-Cluster Master UUID: 5b90382f-a7d7-8dc2-4358-246e96e1013a
   Sub-Cluster Backup UUID:
   Sub-Cluster UUID: 5292b573-6d0c-d8e2-b233-aa15b43a3740
   Sub-Cluster Membership Entry Revision: 0
   Sub-Cluster Member Count: 1
   Sub-Cluster Member UUIDs: 5b90382f-a7d7-8dc2-4358-246e96e1013a
   Sub-Cluster Membership UUID: aa767b5c-5cc5-a904-8224-246e96e1013a
   Unicast Mode Enabled: true
   Maintenance Mode State: OFF
   Config Generation: 2a3be2d8-0006-4b0f-a87a-887ed8242d79 3 2019-03-03T06:39:42.986
[root@xxxxx:~]


 
++ We are able to ping vSAN nodes using vmkping command.  
[root@xxxx:/tmp] esxcfg-vmknic -l | grep -i vmk3
vmk3       20336                                   IPv4      172.x.x.x                           255.xx.2xx.0   172.x.x.x    00:50:56:66:aa:ed 1500    65535     true    STATIC              defaultTcpipStack
vmk3       20336                                   IPv6      xxxx::xxxx:xxxx:xxxx:xxxx                64                     00:50:56:66:aa:ed 1500    65535     true    STATIC, PREFERRED   defaultTcpipStack
[root@xxxx:/tmp]
 [root@xxxx:~] vmkping -I vmk3 172.x.x.x
PING 172.16.200.10 (172.16.200.10): 56 data bytes
64 bytes from 172.x.x.x   : icmp_seq=0 ttl=64 time=6.226 ms
64 bytes from 172.x.x.x   : icmp_seq=1 ttl=64 time=2.879 ms
64 bytes from 172.x.x.x   : icmp_seq=2 ttl=64 time=0.134 ms
 
--- 172.x.x.x ping statistics ---
3 packets transmitted, 3 packets received, 0% packet loss
round-trip min/avg/max = 0.134/3.080/6.226 ms
[root@xxxxx:~] vmkping -I vmk3 172.xx.xx.11
PING 172.x.x.x  (172.x.x.x   ): 56 data bytes
64 bytes from 172.x.x.x: icmp_seq=0 ttl=64 time=0.200 ms
64 bytes from 172.x.x.x: icmp_seq=1 ttl=64 time=0.163 ms
64 bytes from 172.x.x.x: icmp_seq=2 ttl=64 time=0.152 ms
 
--- 172.x.x.x ping statistics ---
3 packets transmitted, 3 packets received, 0% packet loss
round-trip min/avg/max = 0.152/0.172/0.200 ms

Cause

看起来单播注册存在问题。两个节点上的单播配置存在问题。

Resolution

添加缺少的单播代理条目
esxcli vsan cluster unicastagent add -t node -u -U -a -p -i
示例
 
esxcli vsan cluster unicastagent add -t node -u 57ea62b0-9df6-6532-110c-9457a55a37d0 -U true -a XX.XXX.XXX.XX-p 12321 -i vmk3
 [root@xxxxx:~] esxcli vsan cluster unicastagent list
NodeUuid                              IsWitness  Supports Unicast  IP Address      Port  Iface Name
------------------------------------  ---------  ----------------  -------------  -----  ----------
5b90378f-0b0b-2da4-933b-246e96e101b6          0              true  172.x.x.x  12321
5b90380e-927b-73ce-159f-246e96e1018a          0              true  172.x.x.x  12321
[root@xxxx:~]
 
[root@xxxxxx:~] esxcli vsan cluster unicastagent list
NodeUuid                              IsWitness  Supports Unicast  IP Address      Port  Iface Name
------------------------------------  ---------  ----------------  -------------  -----  ----------
5b90378f-0b0b-2da4-933b-246e96e101b6          0              true  172.x.x.x 12321
5b90382f-a7d7-8dc2-4358-246e96e1013a          0              true  172.x.x.x 12321

[root@xxxxx:~]
 
[root@xxxx:/tmp] esxcli vsan cluster unicastagent list
NodeUuid                              IsWitness  Supports Unicast  IP Address      Port  Iface Name
------------------------------------  ---------  ----------------  -------------  -----  ----------
5b90380e-927b-73ce-159f-246e96e1018a          0              true  172.x.x.x  12321
5b90382f-a7d7-8dc2-4358-246e96e1013a          0              true  172.x.x.x  12321
[root@xxxxx:/tmp]
 
 
[root@xxxx:~] esxcli vsan cluster get
Cluster Information
   Enabled: true
   Current Local Time: 2019-03-03T07:48:55Z
   Local Node UUID: 5b90382f-a7d7-8dc2-4358-246e96e1013a
   Local Node Type: NORMAL
   Local Node State: AGENT
   Local Node Health State: HEALTHY
   Sub-Cluster Master UUID: 5b90378f-0b0b-2da4-933b-246e96e101b6
   Sub-Cluster Backup UUID: 5b90380e-927b-73ce-159f-246e96e1018a
   Sub-Cluster UUID: 5292b573-6d0c-d8e2-b233-aa15b43a3740
   Sub-Cluster Membership Entry Revision: 3
   Sub-Cluster Member Count: 3
   Sub-Cluster Member UUIDs: 5b90378f-0b0b-2da4-933b-246e96e101b6, 5b90380e-927b-73ce-159f-246e96e1018a, 5b90382f-a7d7-8dc2-4358-246e96e1013a
   Sub-Cluster Membership UUID: d519d05b-a227-5621-66dc-246e96e101b6
   Unicast Mode Enabled: true
   Maintenance Mode State: OFF
   Config Generation: 2a3be2d8-0006-4b0f-a87a-887ed8242d79 3 2019-03-03T06:39:42.986

Additional Information

本内容以其他语言翻译: 
https://downloads.dell.com/TranslatedPDF/PT-BR_KB530995.pdf
https://downloads.dell.com/TranslatedPDF/ZH-CN_KB530995.pdf
https://downloads.dell.com/TranslatedPDF/AR-EG_KB530995.pdf
https://downloads.dell.com/TranslatedPDF/DE_KB530995.pdf
https://downloads.dell.com/TranslatedPDF/ES_KB530995.pdf
https://downloads.dell.com/TranslatedPDF/FR_KB530995.pdf
https://downloads.dell.com/TranslatedPDF/KO_KB530995.pdf
https://downloads.dell.com/TranslatedPDF/JA_KB530995.pdf
https://downloads.dell.com/TranslatedPDF/IT_KB530995.pdf
https://downloads.dell.com/TranslatedPDF/NL_KB530995.pdf
https://downloads.dell.com/TranslatedPDF/PT_KB530995.pdf
https://downloads.dell.com/TranslatedPDF/RU_KB530995.pdf
https://downloads.dell.com/TranslatedPDF/SV_KB530995.pdf

Affected Products

VxRail Appliance Family

Products

VxRail Appliance Family
Article Properties
Article Number: 000056284
Article Type: Solution
Last Modified: 20 Aug 2025
Version:  6
Find answers to your questions from other Dell users
Support Services
Check if your device is covered by Support Services.