Connectrix MDS: EXT3-fs Error (device sdc1): ext3_readdir: directory #2 contains a hole at offset 0 - kernel
Summary: Connectrix MDS-switch streamt de volgende fout: %KERN-2-SYSTEM_MSG: [63661120.723386] EXT3-fs error (device sdc1): ext3_readdir: directory #2 bevat een gat bij offset 0 - kernel.
Symptoms
Connectrix MDS-switch streamt de volgende fout:
%KERN-2-SYSTEM_MSG: [63661120.723386] EXT3-fs error (device sdc1): ext3_readdir: directory #2 contains a hole at offset 0 - kernel
Het onderstaande is te zien in de uitvoer van de show logging:
2016 Jul 26 19:54:22 Switch Jul 26 19:54:21 %KERN-2-SYSTEM_MSG: [63661120.680361] EXT3-fs error (device sdc1): ext3_readdir: directory #2 contains a hole at offset 0 - kernel 2016 Jul 26 19:54:22 Switch Jul 26 19:54:21 %KERN-2-SYSTEM_MSG: [63661120.702907] EXT3-fs error (device sdc1): ext3_readdir: directory #2 contains a hole at offset 0 - kernel 2016 Jul 26 19:54:22 Switch Jul 26 19:54:21 %KERN-2-SYSTEM_MSG: [63661120.723386] EXT3-fs error (device sdc1): ext3_readdir: directory #2 contains a hole at offset 0 - kernel
Het onderstaande is te zien in de interne flitser van het showsysteem:
`show system internal flash` Mount-on 1K-blocks Used Available Use% Filesystem / 409600 65564 344036 17 /dev/root /proc 0 0 0 0 proc /sys 0 0 0 0 none /isan 1572864 539352 1033512 35 none /var 51200 460 50740 1 none /etc 5120 1624 3496 32 none /nxos/tmp 51200 336 50864 1 none /var/log 51200 8992 42208 18 none /var/home 5120 0 5120 0 none /var/tmp 307200 11628 295572 4 none /var/sysmgr 2097152 124 2097028 1 none /var/sysmgr/ftp 512000 51968 460032 11 none /var/sysmgr/srv_logs 102400 0 102400 0 none /var/sysmgr/ftp/debug_logs 10240 0 10240 0 none /dev/shm 1572864 234276 1338588 15 none /volatile 512000 12 511988 1 none /debug 2048 28 2020 2 none /dev/mqueue 0 0 0 0 none /debugfs 0 0 0 0 nodev /mnt/plog 242430 4458 225455 2 /dev/sdc1 /mnt/fwimg 121219 4127 110833 4 /dev/sdc3 /mnt/cfg/0 75797 4729 67154 7 /dev/sda5 /mnt/cfg/1 75797 4729 67154 7 /dev/sda6 /logflash 15392672 33064 14577684 1 /dev/sdb1 /bootflash 3653168 244900 3222696 8 /dev/sda3 /cgroup 0 0 0 0 vdccontrol /var/sysmgr/startup-cfg 409600 10272 399328 3 none /dev/pts 0 0 0 0 devpts /mnt/pss 38156 5482 30704 16 /dev/sda4 /bootflash_sup-remote 3653168 244896 3222704 8 127.1.1.6:/bootflash/ `show module` Mod Ports Module-Type Model Status --- ----- ----------------------------------- ------------------ ---------- 2 48 2/4/8/10/16 Gbps Advanced FC Module DS-X9448-768K9 ok 3 48 2/4/8/10/16 Gbps Advanced FC Module DS-X9448-768K9 ok 4 48 2/4/8/10/16 Gbps Advanced FC Module DS-X9448-768K9 ok 5 0 Supervisor module-3 DS-X97-SF1-K9 active * 6 0 Supervisor module-3 DS-X97-SF1-K9 ha-standby `show system redundancy status` Redundancy mode --------------- administrative: HA operational: HA This supervisor (sup-1) ----------------------- Redundancy state: Active Supervisor state: Active Internal state: Active with HA standby Other supervisor (sup-2) ------------------------ Redundancy state: Standby Supervisor state: HA standby Internal state: HA standby
Cause
Het flash-storageapparaat is niet gekoppeld volgens het Cisco-probleem "CSCuv67115".
Dit probleem doet zich in eerste instantie alleen voor bij supervisors in stand-by. Het probleem wordt niet opgelost door een ISSU/D, systeemomschakeling of opnieuw laden en wordt waargenomen op een supervisor in een actieve status.
Logflash wordt alleen gebruikt om de uitvoer van foutopsporingsopdrachten op te slaan. Het is niet vereist voor een stabiele werking van het systeem.
Resolution
Tijdelijke oplossing:
Schakel de betreffende supervisor uit en weer in.
In systemen met dubbele toezichthouders wordt dit gedaan door de toezichthouder uit te schakelen met de out-of-service module commando en schakel het weer in met de no poweroff module bevelen. Zorg ervoor dat de supervisor in de stand-bymodus staat, zodat het herstel de stabiliteit van het systeem niet beïnvloedt.
Het is niet voldoende om de module opnieuw op te starten met de reload of system switchover Opdrachten.
Voorbeeld:
Opdrachten:
-
Controleer of de stand-bysupervisor in HA-stand-by staat:
show system redundancy status
-
Schakel de stand-bysupervisormodule uit:
out-of-service module <standby sup>
-
De stand-bysupervisor opstarten:
no poweroff <standby sup>
-
Wait for HA Standby:
show system redundancy status
Houd de switch in de gaten en toon de logging-output om te zien of de EXT3-fs-foutmelding nog steeds wordt geregistreerd op de switch. Als de fout nog steeds wordt geregistreerd, schakelt u over naar de stand-bysupervisor en herhaalt u de stappen 1-4 hierboven.