Connectrix: Cisco: unable to copy run start

Summary: Connectrix: Cisco: unable to copy run start

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Symptoms

'copy running startup' command was aborted since the last system power up or supervisor switchover.
 

Two symptoms are possible. Either:

1) Copying the running config to startup fails at 98%. The following messages are logged to syslog:

%SYSMGR-STANDBY-3-CFGWRITE_REJECT: Discarding request for configuration startup-config sync: configuration action already in progress.
%SYSMGR-3-CFGWRITE_FAILED: Configuration copy failed (error-id 0x401E0000).

2) After a system switchover, the standby supervisor is continuously reset and does not reach 'ha-standby' state. The 'show system reset-reason' command shows the following reset reason for the standby supervisor:

Reason: Reset of standby by active sup due to sysmgr timeout

Cause

Cisco bug - CSCtz29857

This issue may occur if a 'copy running startup' command was aborted since the last system power up or supervisor switchover.

NOTE:
This issue can be prevalent even after ISSU occurs.

Resolution

Workaround:
Contact Support for dplug session with Cisco or reload switch