Dell Unity: 2-Way NDMP backup failing after rebooting Data Domain VTL
Summary: 2-Way NDMP backup failing after rebooting Data Domain VTL (Customer Correctable)
This article applies to
This article does not apply to
This article is not tied to any specific product.
Not all product versions are identified in this article.
Symptoms
- 2-Way NDMP backup failing after rebooting Data Domain VTL
- Dell NetWorker showing Data Domain VTL as offline status however from within Data Domain VTL, it is showing healthy status.
- Dell Unity could not discover any devices presented from Data Domain VTL.
After rebooting Data Domain VTL, Dell Unity displaying LUNZ and with no Data Domain VTLs detected on the probe as shown below:
# svc_nas ALL -devconfig -list -scsi -nondisks SVDM_A : Scsi device table name addr type info ? LUNZ ! 0000000000CL jbox DGC ? ? LUNZ ! 0000000000CL tape DGC ? ? LUNZ ! 0000000000CL tape DGC ? ? LUNZ ! 0000000000CL tape DGC ? ? LUNZ ! 0000000000CL tape DGC ? ? LUNZ ! 0000000000CL tape DGC ? c33t0l0 c33t0l0 tape IBM ULT3580-HH7 c33t0l1 c33t0l1 jbox IBM 3573-TL 0055L3A7800T6A SVDM_B : Scsi device table name addr type info c32t0l0 c32t0l0 tape IBM ULT3580-HH7 c32t0l1 c32t0l1 jbox IBM 3573-TL 0055L3A7800T6A <nas server> : Scsi device table name addr type info ? LUNZ 9n 0000000000CL jbox DGC ? ? LUNZ 9n 0000000000CL tape DGC ? ? LUNZ 9n 0000000000CL tape DGC ? ? LUNZ 9n 0000000000CL tape DGC ? ? LUNZ 9n 0000000000CL tape DGC ? ? LUNZ 9n 0000000000CL tape DGC ? c33t0l0 c33t0l0 tape IBM ULT3580-HH7 c33t0l1 c33t0l1 jbox IBM 3573-TL 0055L3A7800T6A
Original output from before rebooting Data Domain VTL:
# svc_nas ALL -devconfig -list -scsi -nondisks SVDM_A : Scsi device table name addr type info c32t0l0 c32t0l0 jbox STK L180 c32t0l1 c32t0l1 tape IBM ULTRIUM-TD5 c32t0l2 c32t0l2 tape IBM ULTRIUM-TD5 c32t0l3 c32t0l3 tape IBM ULTRIUM-TD5 c32t0l4 c32t0l4 tape IBM ULTRIUM-TD5 c32t0l5 c32t0l5 tape IBM ULTRIUM-TD5 c33t0l0 c33t0l0 tape IBM ULT3580-HH7 c33t0l1 c33t0l1 jbox IBM 3573-TL 0055L3A7800T6A c34t0l0 c34t0l0 tape IBM ULT3580-HH7 c34t0l1 c34t0l1 jbox IBM 3573-TL 0055L3A7800T6A SVDM_B : Scsi device table name addr type info c32t0l0 c32t0l0 tape IBM ULT3580-HH7 c32t0l1 c32t0l1 jbox IBM 3573-TL 0055L3A7800T6A <nas server> : Scsi device table name addr type info c32t0l0 c32t0l0 jbox STK L180 c32t0l1 c32t0l1 tape IBM ULTRIUM-TD5 c32t0l2 c32t0l2 tape IBM ULTRIUM-TD5 c32t0l3 c32t0l3 tape IBM ULTRIUM-TD5 c32t0l4 c32t0l4 tape IBM ULTRIUM-TD5 c32t0l5 c32t0l5 tape IBM ULTRIUM-TD5 c33t0l0 c33t0l0 tape IBM ULT3580-HH7 c33t0l1 c33t0l1 jbox IBM 3573-TL 0055L3A7800T6A c34t0l0 c34t0l0 tape IBM ULT3580-HH7 c34t0l1 c34t0l1 jbox IBM 3573-TL 0055L3A7800T6A
Cause
User added additional physical tape devices and zoned them to using same Dell Unity FC initiator port assigned for Data Domain VTL use.
Resolution
Remove the additional physical tape device with Dell Unity FC initiator port zone to resolve this issue.
Additional Information
As per the Data Domain VTL best practice guide:
Data Domain: Virtual Tape Library Best Practices Guide
VTL Components
Initiators:
- It is required that the FC initiator port must be dedicated to only Data Domain VTL devices.
- Only initiators that must communicate with a particular set of VTL target ports on a Data Domain system should be zoned with that Data Domain system.
- Create a useful alias for every initiator you zone and connect to the Data Domain system, preferably including the hostname and port in the alias name.
- Use only one-to-one zoning; create zones on your Fibre Channel switch composed of only one initiator and one target per zone.
Affected Products
Dell EMC Unity HybridArticle Properties