ECS: GUI Error 6500 (http: 500): Internal Server Error. An internal server error occurred.
Summary: This knowledge article explains why the ECS UI is unable to log in due login Error 6500 (http: 500): Internal Server Error. An internal server error occurred. Please try again.
This article applies to
This article does not apply to
This article is not tied to any specific product.
Not all product versions are identified in this article.
Symptoms
When logging into the UI on a specific node, the following error is seen on the dashboard or end user license agreement notification:
Cause
There are three ECS services responsible for UI login, stat, "ecsportalsvc," and "obcontrolsvc" - these have stale entries which are not allowing the UI to log in.
Resolution
On the concerning node, restart the stat, ecsportalsvc, and obcontrolsvc. There is no impact on restarting these services but it should be noted that any alerts generated on the UI on another node are now linked to these restarts:
Using service tools:
admin@node1:~> svc_node services restart -nw 10 -srv stat ecsportalsvc objcontrolsvc -n self Starting utility inside a screen session
Confirm on the concerning node (rack 1 node 1) that the services have restarted and ensure that there are no services that are not running:
admin@node1:~> svc_node services -status
svc_node v1.2.1 (svc_tools v2.1.0) Started 2022-02-25 11:40:49
Node r1n1:
Services running:
fabric-agent
blobsvc (102925) Started: 2021-12-20 17:07:17 cm (102859) Started: 2021-12-20 17:07:17
coordinatorsvc (102843) Started: 2021-12-20 17:07:17 dataheadsvc (102935) Started: 2021-12-20 17:07:17
dtquery (102951) Started: 2021-12-20 17:07:17 ecsportalsvc (66505) Started: 2022-02-25 11:31:08
eventsvc (102932) Started: 2021-12-20 17:07:17 georeceiver (102950) Started: 2021-12-20 17:07:17
metering (102908) Started: 2021-12-20 17:07:17 objcontrolsvc (69329) Started: 2022-02-25 11:31:32
resourcesvc (102939) Started: 2021-12-20 17:07:17 rm (102851) Started: 2021-12-20 17:07:17
sr (102905) Started: 2021-12-20 17:07:17 ssm (102899) Started: 2021-12-20 17:07:17
stat (65535) Started: 2022-02-25 11:30:55 storageserver (102896) Started: 2021-12-20 17:07:17
vnest (102847) Started: 2021-12-20 17:07:17
Services not running:
<none>
Return to the ECS UI and you can log in without issue.
Affected Products
ECSProducts
ECS Appliance, ECS Appliance Gen 1, ECS Appliance Gen 2, ECS Appliance Gen 3Article Properties
Article Number: 000196746
Article Type: Solution
Last Modified: 05 Mar 2024
Version: 8
Find answers to your questions from other Dell users
Support Services
Check if your device is covered by Support Services.