MFE SCF:延伸設定可搭配 RDF 定義的企業 GNS 群組使用,或移除錯誤封鎖企業 GNS 群組的 RDF 群組

Summary: 延伸設定可搭配 RDF 定義的企業 GNS 群組使用,但企業 GNS 群組應停用擴充。 移除企業 GNS 群組的 RDF 群組被錯誤地封鎖。

This article may have been automatically translated. If you have any feedback regarding its quality, please let us know using the form at the bottom of this page.

Article Content


Symptoms

企業 GNS 群組錯誤地允許延伸功能。此外,企業 GNS 群組的移除 RDF 群組被錯誤地封鎖。

範例 (Dell EMC CS 實驗室): 
DEFINE ENTERPRISE -
GROUP 'GNS_GNSENTEX' -
INCLUDE RDF GROUP = 000120200131,(LCL=03C4) -

DEFINE ENTERPRISE ANY GROUP 'GNS_GNSENTEX' EXTEND -
INCLUDE RDF GROUP=000120200246(LCL=3C5)

DEFINE OF GROUP 'GNS_GNSENTEX'
COMPLETED WITH RETURN CODE: 0-0
REASON 0 = OK
預期結果為:
DEFINE OF GROUP 'GNS_GNSENTEX'
COMPLETED WITH RETURN CODE: 8-33
REASON 33 = ENTERPRISE GROUPS MAY NOT BE EXTENDED
範例 (Dell EMC CS 實驗室):
REMOVE FROM GROUP 'GNS_GNSENTRM' RDF GROUP=000120200246(INCLUDE=3C5)

REMOVE FROM GROUP 'GNS_GNSENTRM'
COMPLETED WITH RETURN CODE: 8-33
REASON 33 = ENTERPRISE GROUPS MAY NOT BE EXTENDED

Cause

這是因為軟體問題所導致。

Resolution

永久修正:
  • 針對 Mainframe Enablers 8.5,已開發 PTF SF85121來修正問題。可從 Dell 線上支援下載。
  • 針對 Mainframe Enablers 8.4,已開發 PTF SF84163來修正問題。可從 Dell 線上支援下載。