DSA-2022-304: Dell Connectrix (Brocade) Security Update for EZswitch Vulnerability
Summary: Dell Connectrix (Brocade) remediation is available for an EZswitch vulnerability in Brocade Fabric OS (FOS) software that may be exploited by malicious users to compromise the affected system. ...
This article applies to
This article does not apply to
This article is not tied to any specific product.
Not all product versions are identified in this article.
Impact
Critical
Details
| Third-party Component | CVE | More information |
| Connectrix (Brocade) FOS | CVE-2022-33186 | See NVD (http://nvd.nist.gov/ |
| Third-party Component | CVE | More information |
| Connectrix (Brocade) FOS | CVE-2022-33186 | See NVD (http://nvd.nist.gov/ |
Affected Products & Remediation
| CVE Addressed | Product | Affected Versions | Updated Versions | Link to Update |
| CVE-2022-33186 | Connectrix (Brocade) FOS | Brocade Fabric OS (FOS) v9.1.1, v9.0.1e, v8.2.3c, and v7.4.2j and earlier | v9.1.1_01 v9.0.1e1, v8.2.3c1 v7.4.2j1 |
Link to update |
| CVE Addressed | Product | Affected Versions | Updated Versions | Link to Update |
| CVE-2022-33186 | Connectrix (Brocade) FOS | Brocade Fabric OS (FOS) v9.1.1, v9.0.1e, v8.2.3c, and v7.4.2j and earlier | v9.1.1_01 v9.0.1e1, v8.2.3c1 v7.4.2j1 |
Link to update |
Workarounds & Mitigations
To remove any exposure to this vulnerability, Brocade Fabric OS switch administrators must disable EZServer support or upgrade to a version of FOS that has the EZServer module removed.
Disabling EZServer is accomplished by using the CLI command "configurechassis." Disabling the EZServer in the switch configuration prevents any exposure to this vulnerability. This option is only available on FOS versions v8.1.0b and later. Customers running on older versions of FOS, including v7.4.2j, do not have this option and must upgrade to FOS v7.4.2j1 to protect their switches.
Customers that elect to upgrade their FOS version can obtain a patch with the EZServer module removed:
- FOS v9.1.1_01 and higher versions
- FOS v9.0.1e1 and higher versions
- FOS v8.2.3c1 and higher versions
- FOS v7.4.2j1 and higher versions
Example showing how to disable the EZServer module:
brocadeswitch:admin> configurechassis Configure... cfgload attributes (yes, y, no, n): [no] ssl attributes (yes, y, no, n): [no] webtools attributes (yes, y, no, n): [no] y ... Login Session Timeout (in secs): (60..432000) [7200] EZserver Enabled (yes, y, no, n): [yes] no ... brocadeswitch:admin >
Notes:
The following actions reenable EZServer on Fabric OS versions that do not have the EZServer module entirely removed:
- firmwarecleaninstall
- config removall
- configdefault
- factory reset
Revision History
| Revision | Date | Description |
| 1.0 | 2022-11-09 | Initial Release |
| 2.0 | 2023-02-14 | Corrected "Affected Product" section under "Article Properties." |
Related Information
Legal Disclaimer
Affected Products
Connectrix, Connectrix, Connectrix B-Series, Connectrix B-Series, Brocade 5100, Brocade 6520, Brocade G620, Brocade M6505, Connectrix, Connectrix B-Series Fabric OS 9.X, Connectrix B-Series Software, Connectrix DS-300B, Connectrix DS-6505B
, Connectrix DS-6510B, Connectrix DS-6620B, Connectrix DS-6620B-V2, Connectrix DS-6630B, Connectrix DS-6630B-V2, Connectrix DS-7720B, Connectrix DS-7730B, Connectrix ED-DCX6-4B, Connectrix ED-DCX6-8B, Connectrix ED-DCX7-4B, Connectrix ED-DCX7-8B, Connectrix ED-DCX8510-4B, Connectrix ED-DCX8510-8B, Connectrix MP-7800B, Connectrix MP-7810B, Connectrix MP-7840B, Product Security Information
...
Article Properties
Article Number: 000205092
Article Type: Dell Security Advisory
Last Modified: 18 Sep 2025
Find answers to your questions from other Dell users
Support Services
Check if your device is covered by Support Services.