VCF op Dell VxRail: VI-WLD cluster add failed with error "Perform dvs related validations"
Summary: VCF op VxRail Workload domain cluster Add for VI-WLD failed with error "Perform dvs related validations. Incompatibele vmnic doorgegeven in host hostxx.abc.xyz specificatie" op vcf op vxrail 4.4.1.1 met VxRail 7.0.371. ...
Symptoms
Tijdens Workload Domain Cluster Add voor VI-WLD kan een gebruiker de onderstaande fout zien in het deelvenster Tasks van de SDDC Manager:
Description: Perform dvs related validations. Failed Error: Incompatible vmnic passed in host hostxx.abc.com specification

Domeinmanager.log:
2023-02-03T14:19:05.021+0000 INFO [vcf_dm,cf4d3c3d17f10a83,bd58] [c.v.e.s.c.c.v.vsphere.VcManagerBase,dm-exec-5] In total 5 vmnics are in-use: ["vusb0","vmnic3","vmnic7","vmnic2","vmnic5"]
2023-02-03T14:19:05.021+0000 DEBUG [vcf_dm,cf4d3c3d17f10a83,bd58] [c.v.v.v.p.service.NICServicePlugin,dm-exec-5] In Use Pnics ["vusb0","vmnic3","vmnic7","vmnic2","vmnic5"]
2023-02-03T14:19:05.021+0000 DEBUG [vcf_dm,cf4d3c3d17f10a83,bd58] [c.v.v.v.p.service.NICServicePlugin,dm-exec-5] Translating for vmnic0
2023-02-03T14:19:05.021+0000 DEBUG [vcf_dm,cf4d3c3d17f10a83,bd58] [c.v.v.v.p.service.NICServicePlugin,dm-exec-5] Link speed null
2023-02-03T14:19:05.021+0000 DEBUG [vcf_dm,cf4d3c3d17f10a83,bd58] [c.v.v.v.p.service.NICServicePlugin,dm-exec-5] Translating for vmnic1
2023-02-03T14:19:05.022+0000 DEBUG [vcf_dm,cf4d3c3d17f10a83,bd58] [c.v.v.v.p.service.NICServicePlugin,dm-exec-5] Link speed null
2023-02-03T14:19:05.022+0000 DEBUG [vcf_dm,cf4d3c3d17f10a83,bd58] [c.v.v.v.p.service.NICServicePlugin,dm-exec-5] Translating for vmnic2
2023-02-03T14:19:05.022+0000 DEBUG [vcf_dm,cf4d3c3d17f10a83,bd58] [c.v.v.v.p.service.NICServicePlugin,dm-exec-5] Link speed {"speedMb":25000,"duplex":true}
2023-02-03T14:19:05.022+0000 DEBUG [vcf_dm,cf4d3c3d17f10a83,bd58] [c.v.v.v.p.service.NICServicePlugin,dm-exec-5] Translating for vmnic3
2023-02-03T14:19:05.022+0000 DEBUG [vcf_dm,cf4d3c3d17f10a83,bd58] [c.v.v.v.p.service.NICServicePlugin,dm-exec-5] Link speed {"speedMb":25000,"duplex":true}
2023-02-03T14:19:05.022+0000 DEBUG [vcf_dm,cf4d3c3d17f10a83,bd58] [c.v.v.v.p.service.NICServicePlugin,dm-exec-5] Translating for vmnic4
2023-02-03T14:19:05.022+0000 DEBUG [vcf_dm,cf4d3c3d17f10a83,bd58] [c.v.v.v.p.service.NICServicePlugin,dm-exec-5] Link speed {"speedMb":25000,"duplex":true}
2023-02-03T14:19:05.022+0000 DEBUG [vcf_dm,cf4d3c3d17f10a83,bd58] [c.v.v.v.p.service.NICServicePlugin,dm-exec-5] Translating for vmnic5
2023-02-03T14:19:05.022+0000 DEBUG [vcf_dm,cf4d3c3d17f10a83,bd58] [c.v.v.v.p.service.NICServicePlugin,dm-exec-5] Link speed {"speedMb":25000,"duplex":true}
2023-02-03T14:19:05.023+0000 DEBUG [vcf_dm,cf4d3c3d17f10a83,bd58] [c.v.v.v.p.service.NICServicePlugin,dm-exec-5] Translating for vmnic6
2023-02-03T14:19:05.023+0000 DEBUG [vcf_dm,cf4d3c3d17f10a83,bd58] [c.v.v.v.p.service.NICServicePlugin,dm-exec-5] Link speed null
2023-02-03T14:19:05.023+0000 DEBUG [vcf_dm,cf4d3c3d17f10a83,bd58] [c.v.v.v.p.service.NICServicePlugin,dm-exec-5] Translating for vmnic7
2023-02-03T14:19:05.023+0000 DEBUG [vcf_dm,cf4d3c3d17f10a83,bd58] [c.v.v.v.p.service.NICServicePlugin,dm-exec-5] Link speed {"speedMb":25000,"duplex":true}
2023-02-03T14:19:05.023+0000 DEBUG [vcf_dm,cf4d3c3d17f10a83,bd58] [c.v.v.v.p.service.NICServicePlugin,dm-exec-5] Translating for vusb0
2023-02-03T14:19:05.023+0000 DEBUG [vcf_dm,cf4d3c3d17f10a83,bd58] [c.v.v.v.p.service.NICServicePlugin,dm-exec-5] Link speed {"speedMb":100,"duplex":true}
2023-02-03T14:19:05.036+0000 ERROR [vcf_dm,cf4d3c3d17f10a83,bd58] [c.v.e.s.o.model.error.ErrorFactory,dm-exec-5] [46IH24] VSPHERE_INCOMPATIBLE_VMNIC_SPEC_FAILED Incompatible vmnic vmnic6 passed in host vh01-abc.xyz specification
Cause
Een slechte NIC-status op een van de hosts in het cluster die is toegevoegd, veroorzaakt deze fout.
Het kan zijn dat de fysieke NIC niet beschikbaar is of dat de verbindingssnelheid van de NIC niet overeenkomt met andere NIC's op de host.
Resolution
Om dit probleem op te lossen:
Identificeer de gerapporteerde host en de fysieke NIC uit het domainmanager-logboekbestand.
Controleer de fysieke NIC-status en de verbindingssnelheid. Als de poort niet werkt of als de koppelingssnelheid niet correct is, voert u de onderstaande stappen één voor één uit totdat het probleem is opgelost:
- Probeer de netwerkkabel opnieuw te koppelen.
- Valideer de configuratie van de switchpoort.
- Verwissel de netwerkkabel met een goed werkende kabel.
- Start de host opnieuw op en controleer de vmnic-status.
Zodra de fysieke NIC-status goed is, gaat u als volgt te werk:
- Probeer opnieuw een mislukte taak voor het toevoegen van een workloaddomeincluster in SDDC Manager.