VCF på Dell VxRail: VI-WLD-klustertillägget misslyckades med felet "Perform dvs related validations"
Summary: VCF på VxRail Workload domain cluster Add for VI-WLD failed with error "Perform dvs related validations. Inkompatibelt vmnic passed in host hostxx.abc.xyz specification" på vcf på vxrail 4.4.1.1 med VxRail 7.0.371. ...
This article applies to
This article does not apply to
This article is not tied to any specific product.
Not all product versions are identified in this article.
Symptoms
Under arbetsbelastningsdomänklustertillägg för VI-WLD kan nedanstående fel visas i aktivitetsfönstret i SDDC Manager:
Description: Perform dvs related validations. Failed Error: Incompatible vmnic passed in host hostxx.abc.com specification

Domainmanager.log:
2023-02-03T14:19:05.021+0000 INFO [vcf_dm,cf4d3c3d17f10a83,bd58] [c.v.e.s.c.c.v.vsphere.VcManagerBase,dm-exec-5] In total 5 vmnics are in-use: ["vusb0","vmnic3","vmnic7","vmnic2","vmnic5"]
2023-02-03T14:19:05.021+0000 DEBUG [vcf_dm,cf4d3c3d17f10a83,bd58] [c.v.v.v.p.service.NICServicePlugin,dm-exec-5] In Use Pnics ["vusb0","vmnic3","vmnic7","vmnic2","vmnic5"]
2023-02-03T14:19:05.021+0000 DEBUG [vcf_dm,cf4d3c3d17f10a83,bd58] [c.v.v.v.p.service.NICServicePlugin,dm-exec-5] Translating for vmnic0
2023-02-03T14:19:05.021+0000 DEBUG [vcf_dm,cf4d3c3d17f10a83,bd58] [c.v.v.v.p.service.NICServicePlugin,dm-exec-5] Link speed null
2023-02-03T14:19:05.021+0000 DEBUG [vcf_dm,cf4d3c3d17f10a83,bd58] [c.v.v.v.p.service.NICServicePlugin,dm-exec-5] Translating for vmnic1
2023-02-03T14:19:05.022+0000 DEBUG [vcf_dm,cf4d3c3d17f10a83,bd58] [c.v.v.v.p.service.NICServicePlugin,dm-exec-5] Link speed null
2023-02-03T14:19:05.022+0000 DEBUG [vcf_dm,cf4d3c3d17f10a83,bd58] [c.v.v.v.p.service.NICServicePlugin,dm-exec-5] Translating for vmnic2
2023-02-03T14:19:05.022+0000 DEBUG [vcf_dm,cf4d3c3d17f10a83,bd58] [c.v.v.v.p.service.NICServicePlugin,dm-exec-5] Link speed {"speedMb":25000,"duplex":true}
2023-02-03T14:19:05.022+0000 DEBUG [vcf_dm,cf4d3c3d17f10a83,bd58] [c.v.v.v.p.service.NICServicePlugin,dm-exec-5] Translating for vmnic3
2023-02-03T14:19:05.022+0000 DEBUG [vcf_dm,cf4d3c3d17f10a83,bd58] [c.v.v.v.p.service.NICServicePlugin,dm-exec-5] Link speed {"speedMb":25000,"duplex":true}
2023-02-03T14:19:05.022+0000 DEBUG [vcf_dm,cf4d3c3d17f10a83,bd58] [c.v.v.v.p.service.NICServicePlugin,dm-exec-5] Translating for vmnic4
2023-02-03T14:19:05.022+0000 DEBUG [vcf_dm,cf4d3c3d17f10a83,bd58] [c.v.v.v.p.service.NICServicePlugin,dm-exec-5] Link speed {"speedMb":25000,"duplex":true}
2023-02-03T14:19:05.022+0000 DEBUG [vcf_dm,cf4d3c3d17f10a83,bd58] [c.v.v.v.p.service.NICServicePlugin,dm-exec-5] Translating for vmnic5
2023-02-03T14:19:05.022+0000 DEBUG [vcf_dm,cf4d3c3d17f10a83,bd58] [c.v.v.v.p.service.NICServicePlugin,dm-exec-5] Link speed {"speedMb":25000,"duplex":true}
2023-02-03T14:19:05.023+0000 DEBUG [vcf_dm,cf4d3c3d17f10a83,bd58] [c.v.v.v.p.service.NICServicePlugin,dm-exec-5] Translating for vmnic6
2023-02-03T14:19:05.023+0000 DEBUG [vcf_dm,cf4d3c3d17f10a83,bd58] [c.v.v.v.p.service.NICServicePlugin,dm-exec-5] Link speed null
2023-02-03T14:19:05.023+0000 DEBUG [vcf_dm,cf4d3c3d17f10a83,bd58] [c.v.v.v.p.service.NICServicePlugin,dm-exec-5] Translating for vmnic7
2023-02-03T14:19:05.023+0000 DEBUG [vcf_dm,cf4d3c3d17f10a83,bd58] [c.v.v.v.p.service.NICServicePlugin,dm-exec-5] Link speed {"speedMb":25000,"duplex":true}
2023-02-03T14:19:05.023+0000 DEBUG [vcf_dm,cf4d3c3d17f10a83,bd58] [c.v.v.v.p.service.NICServicePlugin,dm-exec-5] Translating for vusb0
2023-02-03T14:19:05.023+0000 DEBUG [vcf_dm,cf4d3c3d17f10a83,bd58] [c.v.v.v.p.service.NICServicePlugin,dm-exec-5] Link speed {"speedMb":100,"duplex":true}
2023-02-03T14:19:05.036+0000 ERROR [vcf_dm,cf4d3c3d17f10a83,bd58] [c.v.e.s.o.model.error.ErrorFactory,dm-exec-5] [46IH24] VSPHERE_INCOMPATIBLE_VMNIC_SPEC_FAILED Incompatible vmnic vmnic6 passed in host vh01-abc.xyz specification
Cause
En felaktig NIC-status på en av värdarna i klustret som läggs till orsakar felet.
Det kan antingen vara att det fysiska nätverkskortet är nere eller att länkhastigheten för nätverkskortet inte matchar med andra nätverkskort på värden.
Resolution
Gör så här för att lösa problemet:
Identifiera den rapporterade värden och det fysiska nätverkskortet från loggfilen för domainmanager.
Kontrollera fysisk NIC-status och länkhastighet. Om porten är nere eller länkhastigheten inte är korrekt utför du nedanstående steg, ett i taget, tills problemet är löst:
- Försök att koppla från och sätta tillbaka nätverkskabeln.
- Validera switchportens konfiguration.
- Byt nätverkskabeln mot en som du vet fungerar.
- Starta om värden och kontrollera vmnic-status.
När den fysiska NIC-statusen är bra:
- Försök lägga till uppgift för arbetsbelastningsdomänkluster på nytt i SDDC Manager.
Affected Products
VxRailArticle Properties
Article Number: 000209909
Article Type: Solution
Last Modified: 17 Jan 2024
Version: 3
Find answers to your questions from other Dell users
Support Services
Check if your device is covered by Support Services.