VCF na platformie Dell VxRail: Dodanie klastra VI-WLD nie powiodło się z błędem "Perform dvs related validations"
Summary: VCF on VxRail Workload domain cluster Add for VI-WLD failed with error "Perform dvs related validations. Niezgodna vmnic przekazana w specyfikacji hostxx.abc.xyz hosta" na vcf na vxrail 4.4.1.1 z VxRail 7.0.371. ...
Symptoms
Podczas dodawania klastra domeny obciążenia roboczego dla VI-WLD użytkownik może zobaczyć poniższy błąd w okienku Zadania menedżera SDDC:
Description: Perform dvs related validations. Failed Error: Incompatible vmnic passed in host hostxx.abc.com specification

Domainmanager.log:
2023-02-03T14:19:05.021+0000 INFO [vcf_dm,cf4d3c3d17f10a83,bd58] [c.v.e.s.c.c.v.vsphere.VcManagerBase,dm-exec-5] In total 5 vmnics are in-use: ["vusb0","vmnic3","vmnic7","vmnic2","vmnic5"]
2023-02-03T14:19:05.021+0000 DEBUG [vcf_dm,cf4d3c3d17f10a83,bd58] [c.v.v.v.p.service.NICServicePlugin,dm-exec-5] In Use Pnics ["vusb0","vmnic3","vmnic7","vmnic2","vmnic5"]
2023-02-03T14:19:05.021+0000 DEBUG [vcf_dm,cf4d3c3d17f10a83,bd58] [c.v.v.v.p.service.NICServicePlugin,dm-exec-5] Translating for vmnic0
2023-02-03T14:19:05.021+0000 DEBUG [vcf_dm,cf4d3c3d17f10a83,bd58] [c.v.v.v.p.service.NICServicePlugin,dm-exec-5] Link speed null
2023-02-03T14:19:05.021+0000 DEBUG [vcf_dm,cf4d3c3d17f10a83,bd58] [c.v.v.v.p.service.NICServicePlugin,dm-exec-5] Translating for vmnic1
2023-02-03T14:19:05.022+0000 DEBUG [vcf_dm,cf4d3c3d17f10a83,bd58] [c.v.v.v.p.service.NICServicePlugin,dm-exec-5] Link speed null
2023-02-03T14:19:05.022+0000 DEBUG [vcf_dm,cf4d3c3d17f10a83,bd58] [c.v.v.v.p.service.NICServicePlugin,dm-exec-5] Translating for vmnic2
2023-02-03T14:19:05.022+0000 DEBUG [vcf_dm,cf4d3c3d17f10a83,bd58] [c.v.v.v.p.service.NICServicePlugin,dm-exec-5] Link speed {"speedMb":25000,"duplex":true}
2023-02-03T14:19:05.022+0000 DEBUG [vcf_dm,cf4d3c3d17f10a83,bd58] [c.v.v.v.p.service.NICServicePlugin,dm-exec-5] Translating for vmnic3
2023-02-03T14:19:05.022+0000 DEBUG [vcf_dm,cf4d3c3d17f10a83,bd58] [c.v.v.v.p.service.NICServicePlugin,dm-exec-5] Link speed {"speedMb":25000,"duplex":true}
2023-02-03T14:19:05.022+0000 DEBUG [vcf_dm,cf4d3c3d17f10a83,bd58] [c.v.v.v.p.service.NICServicePlugin,dm-exec-5] Translating for vmnic4
2023-02-03T14:19:05.022+0000 DEBUG [vcf_dm,cf4d3c3d17f10a83,bd58] [c.v.v.v.p.service.NICServicePlugin,dm-exec-5] Link speed {"speedMb":25000,"duplex":true}
2023-02-03T14:19:05.022+0000 DEBUG [vcf_dm,cf4d3c3d17f10a83,bd58] [c.v.v.v.p.service.NICServicePlugin,dm-exec-5] Translating for vmnic5
2023-02-03T14:19:05.022+0000 DEBUG [vcf_dm,cf4d3c3d17f10a83,bd58] [c.v.v.v.p.service.NICServicePlugin,dm-exec-5] Link speed {"speedMb":25000,"duplex":true}
2023-02-03T14:19:05.023+0000 DEBUG [vcf_dm,cf4d3c3d17f10a83,bd58] [c.v.v.v.p.service.NICServicePlugin,dm-exec-5] Translating for vmnic6
2023-02-03T14:19:05.023+0000 DEBUG [vcf_dm,cf4d3c3d17f10a83,bd58] [c.v.v.v.p.service.NICServicePlugin,dm-exec-5] Link speed null
2023-02-03T14:19:05.023+0000 DEBUG [vcf_dm,cf4d3c3d17f10a83,bd58] [c.v.v.v.p.service.NICServicePlugin,dm-exec-5] Translating for vmnic7
2023-02-03T14:19:05.023+0000 DEBUG [vcf_dm,cf4d3c3d17f10a83,bd58] [c.v.v.v.p.service.NICServicePlugin,dm-exec-5] Link speed {"speedMb":25000,"duplex":true}
2023-02-03T14:19:05.023+0000 DEBUG [vcf_dm,cf4d3c3d17f10a83,bd58] [c.v.v.v.p.service.NICServicePlugin,dm-exec-5] Translating for vusb0
2023-02-03T14:19:05.023+0000 DEBUG [vcf_dm,cf4d3c3d17f10a83,bd58] [c.v.v.v.p.service.NICServicePlugin,dm-exec-5] Link speed {"speedMb":100,"duplex":true}
2023-02-03T14:19:05.036+0000 ERROR [vcf_dm,cf4d3c3d17f10a83,bd58] [c.v.e.s.o.model.error.ErrorFactory,dm-exec-5] [46IH24] VSPHERE_INCOMPATIBLE_VMNIC_SPEC_FAILED Incompatible vmnic vmnic6 passed in host vh01-abc.xyz specification
Cause
Nieprawidłowy stan karty sieciowej na jednym z hostów w klastrze, który został dodany, powoduje ten błąd.
Może to być fizyczna karta sieciowa nie działa lub szybkość łącza karty sieciowej nie pasuje do innych kart sieciowych na hoście.
Resolution
Rozwiązanie problemu:
Zidentyfikuj zgłoszony host i fizyczną kartę sieciowa z pliku dziennika domainmanager.
Sprawdź stan fizycznej karty sieciowej i szybkość łącza. Jeśli port nie działa lub szybkość łącza jest nieprawidłowa, wykonaj poniższe czynności krok po drugim, aż problem zostanie rozwiązany:
- Spróbuj ponownie podsunąć kabel sieciowy.
- Sprawdź konfigurację portu przełącznika.
- Zamień kabel sieciowy na sprawny.
- Uruchom ponownie hosta i sprawdź stan vmnic.
Gdy fizyczny stan karty sieciowej jest prawidłowy, wykonaj następujące czynności:
- Ponów próbę nieudanego klastra domeny obciążenia roboczego Dodaj zadanie w menedżerze SDDC.