ECS: xDoctor: RAP163: Kritisk systemhukommelseshændelse
Summary: Der er opstået en kritisk systemhukommelseshændelse, som skal gennemgås og DIMM-udskiftning.
This article applies to
This article does not apply to
This article is not tied to any specific product.
Not all product versions are identified in this article.
Symptoms
xDoctor rapporterer en kritisk systemhukommelseshændelse, der skal gennemgås.
------------------------------------
ERROR - Critical System Memory Event
------------------------------------
Node = Nodes
Extra = {'Nodes': {'169.254.1.1': ['Memory #0x02 - Uncorrectable ECC (UnCorrectable ECC | DIMMB1) (06/10/2023 08:45:16)', 'Memory #0x03 - Uncorrectable ECC (UnCorrectable ECC | DIMMB1) (06/10/2023 08:45:16)', 'Memory Mmry ECC Sensor - Correctable ECC (11/26/2015 12:38:51)']}}
RAP = RAP163
Solution = KB 215723
Timestamp = 2023-07-10_170539
PSNT = CKMXXXXXXXXXXX @ 4.8-92.0Cause
BEMÆRK: Hvis nogen af DIMM-modulerne mangler, eller der vises en hændelse, der ikke kan rettes, i systemets hændelseslogfiler (SEL), skal DIMM-modulerne udskiftes.
- Kontroller SEL-logfilerne for at bekræfte, at der er uoprettelige fejl på noden.
Kommando: (Fjernkommando)
# sudo ipmitool -H <iDrac IP> -U root -P passwd -I lanplus sel elist
Kommando: (Lokal node)
# sudo ipmitool sel elist
Eksempel:
admin@node1:~> sudo ipmitool -H 192.XXX.2XX.107 -U root -P passwd -I lanplus sel elist 1 | 12/04/2021 | 07:29:19 | Event Logging Disabled SEL | Log area reset/cleared | Asserted 2 | 12/29/2021 | 23:00:29 | Memory Mem ECC Warning | Transition to Critical from less severe | Asserted 3 | 01/26/2022 | 11:44:08 | Memory Mem ECC Warning | Transition to Critical from less severe | Asserted 4 | 08/03/2022 | 18:31:45 | Power Supply PS Redundancy | Redundancy Lost | Asserted 5 | 08/03/2022 | 18:31:48 | Power Supply Status | Power Supply AC lost | Asserted 6 | 08/03/2022 | 18:43:14 | Power Supply Status | Power Supply AC lost | Deasserted 7 | 08/03/2022 | 18:43:22 | Power Supply PS Redundancy | Fully Redundant | Asserted 8 | 08/03/2022 | 18:51:27 | Power Supply PS Redundancy | Redundancy Lost | Asserted 9 | 08/03/2022 | 18:51:27 | Power Supply Status | Power Supply AC lost | Asserted a | 08/03/2022 | 19:02:03 | Power Supply Status | Power Supply AC lost | Deasserted b | 08/03/2022 | 19:02:14 | Power Supply PS Redundancy | Fully Redundant | Asserted c | 01/19/2023 | 05:38:27 | Memory Mem ECC Warning | Transition to Critical from less severe | Asserted d | 02/06/2023 | 02:10:25 | Memory Mem ECC Warning | Transition to Critical from less severe | Asserted e | 03/02/2023 | 17:12:15 | Memory Mem ECC Warning | Transition to Critical from less severe | Asserted f | 05/09/2023 | 15:56:41 | Memory #0x02 | Uncorrectable ECC (UnCorrectable ECC | DIMMA1) | Asserted 10 | 05/09/2023 | 17:16:16 | Memory Mem ECC Warning | Transition to Critical from less severe | Asserted 11 | 05/09/2023 | 20:57:41 | Memory #0x02 | Uncorrectable ECC (UnCorrectable ECC | DIMMA1) | Asserted 12 | 05/09/2023 | 20:59:25 | Unknown #0x2e | | Asserted 13 | 05/09/2023 | 20:59:25 | Memory #0x02 | Uncorrectable ECC (UnCorrectable ECC | DIMMB1) | Asserted 14 | 05/11/2023 | 05:43:34 | Memory Mem ECC Warning | Transition to Critical from less severe | Asserted 15 | 06/10/2023 | 08:43:26 | Memory #0x02 | Uncorrectable ECC (UnCorrectable ECC | DIMMA1) | Asserted 16 | 06/10/2023 | 08:45:16 | Unknown #0x2e | | Asserted 17 | 06/10/2023 | 08:45:16 | Memory #0x02 | Uncorrectable ECC (UnCorrectable ECC | DIMMA1) | Asserted 18 | 06/10/2023 | 08:45:16 | Memory #0x02 | Uncorrectable ECC (UnCorrectable ECC | DIMMB1) | Asserted
- Bekræft, om DIMM-moduler mangler på grund af hændelsen.
Kommando:
# sudo dmidecode -t memory | grep "Locator\|Size" | grep -v "Cache\|Volatile\|Cache\|Logical\|Bank"
Eksempel:
admin@node1:~> sudo dmidecode -t memory | grep "Locator\|Size" | grep -v "Cache\|Volatile\|Cache\|Logical\|Bank"
Size: No Module Installed <-- DIMM is missing
Locator: A1
Size: 16384 MB
Locator: A2
Size: No Module Installed
Locator: A3
Size: No Module Installed
Locator: A4
Size: No Module Installed
Locator: A5
Size: No Module Installed
Locator: A6
Size: No Module Installed
Locator: A7
Size: No Module Installed
Locator: A8
Size: 16384 MB
Locator: B1
Size: 16384 MB
Locator: B2
Size: No Module Installed
Locator: B3
Size: No Module Installed
Locator: B4
Resolution
Indsaml output fra ovenstående kommandoer, og åbn en serviceanmodning med henvisning til KB-215723 for at gennemse serverens DIMM-modul for udskiftning.
Hvis DIMM-modulet er blevet udskiftet, kræver xDoctor version 4.8.92.0 eller nyere, at SEL en på den berørte knude ryddes. Det stopper yderligere advarsler på denne logpost.
Hvis DIMM-modulet er blevet udskiftet, kræver xDoctor version 4.8.92.0 eller nyere, at SEL en på den berørte knude ryddes. Det stopper yderligere advarsler på denne logpost.
Eksempel - Rydning af systemets hændelseslog (SEL):
Forespørg på iDRAC for at hente systemets hændelseslog, og bekræft, at fejlen findes i outputtet.
Husk, før du rydder SEL, skal du kontrollere, om der er andre fejl, der skal løses. Gem også loggen på /var/log/hardware som beskrevet i KB 49569.
I dette eksempel svarer 192.168.219.101 til iDRAC IP for node 1:
admin@provo~> ipmitool -I lanplus -H 192.168.219.101 -U root -P passwd sel list 1 | 01/06/2022 | 04:34:58 | Event Logging Disabled #0x72 | Log area reset/cleared | Asserted 2 | 02/03/2022 | 17:15:21 | Physical Security #0x73 | General Chassis intrusion () | Asserted 3 | 02/03/2022 | 17:15:28 | Physical Security #0x73 | General Chassis intrusion () | Deasserted 4 | 08/18/2023 | 01:44:01 | Memory #0x02 | Uncorrectable ECC (UnCorrectable ECC | DIMMA1) | Asserted
Ryd SEL'en:
admin@provo:~> ipmitool -I lanplus -H 192.168.219.101 -U root -P passwd sel clear Clearing SEL. Please allow a few seconds to erase.
Godkend, at listen blev ryddet:
admin@provo~> ipmitool -I lanplus -H 192.168.219.101 -U root -P passwd sel list 1 | 08/30/2023 | 12:56:55 | Event Logging Disabled #0x72 | Log area reset/cleared | Asserted