ECS:xDoctor:RAP163:严重系统内存事件
Summary: 发生了严重系统内存事件,需要检视并更换 DIMM。
This article applies to
This article does not apply to
This article is not tied to any specific product.
Not all product versions are identified in this article.
Symptoms
xDoctor 报告需要审查的关键系统内存事件。
------------------------------------
ERROR - Critical System Memory Event
------------------------------------
Node = Nodes
Extra = {'Nodes': {'169.254.1.1': ['Memory #0x02 - Uncorrectable ECC (UnCorrectable ECC | DIMMB1) (06/10/2023 08:45:16)', 'Memory #0x03 - Uncorrectable ECC (UnCorrectable ECC | DIMMB1) (06/10/2023 08:45:16)', 'Memory Mmry ECC Sensor - Correctable ECC (11/26/2015 12:38:51)']}}
RAP = RAP163
Solution = KB 215723
Timestamp = 2023-07-10_170539
PSNT = CKMXXXXXXXXXXX @ 4.8-92.0Cause
提醒:如果缺少任何 DIMM 或系统事件日志 (SEL) 中显示“不可纠正”事件,则必须更换 DIMM。
- 检查 SEL 日志以确认节点上存在不可纠正的错误。
命令:(远程命令)
# sudo ipmitool -H <iDrac IP> -U root -P passwd -I lanplus sel elist
命令:(本地节点)
# sudo ipmitool sel elist
示例:
admin@node1:~> sudo ipmitool -H 192.XXX.2XX.107 -U root -P passwd -I lanplus sel elist 1 | 12/04/2021 | 07:29:19 | Event Logging Disabled SEL | Log area reset/cleared | Asserted 2 | 12/29/2021 | 23:00:29 | Memory Mem ECC Warning | Transition to Critical from less severe | Asserted 3 | 01/26/2022 | 11:44:08 | Memory Mem ECC Warning | Transition to Critical from less severe | Asserted 4 | 08/03/2022 | 18:31:45 | Power Supply PS Redundancy | Redundancy Lost | Asserted 5 | 08/03/2022 | 18:31:48 | Power Supply Status | Power Supply AC lost | Asserted 6 | 08/03/2022 | 18:43:14 | Power Supply Status | Power Supply AC lost | Deasserted 7 | 08/03/2022 | 18:43:22 | Power Supply PS Redundancy | Fully Redundant | Asserted 8 | 08/03/2022 | 18:51:27 | Power Supply PS Redundancy | Redundancy Lost | Asserted 9 | 08/03/2022 | 18:51:27 | Power Supply Status | Power Supply AC lost | Asserted a | 08/03/2022 | 19:02:03 | Power Supply Status | Power Supply AC lost | Deasserted b | 08/03/2022 | 19:02:14 | Power Supply PS Redundancy | Fully Redundant | Asserted c | 01/19/2023 | 05:38:27 | Memory Mem ECC Warning | Transition to Critical from less severe | Asserted d | 02/06/2023 | 02:10:25 | Memory Mem ECC Warning | Transition to Critical from less severe | Asserted e | 03/02/2023 | 17:12:15 | Memory Mem ECC Warning | Transition to Critical from less severe | Asserted f | 05/09/2023 | 15:56:41 | Memory #0x02 | Uncorrectable ECC (UnCorrectable ECC | DIMMA1) | Asserted 10 | 05/09/2023 | 17:16:16 | Memory Mem ECC Warning | Transition to Critical from less severe | Asserted 11 | 05/09/2023 | 20:57:41 | Memory #0x02 | Uncorrectable ECC (UnCorrectable ECC | DIMMA1) | Asserted 12 | 05/09/2023 | 20:59:25 | Unknown #0x2e | | Asserted 13 | 05/09/2023 | 20:59:25 | Memory #0x02 | Uncorrectable ECC (UnCorrectable ECC | DIMMB1) | Asserted 14 | 05/11/2023 | 05:43:34 | Memory Mem ECC Warning | Transition to Critical from less severe | Asserted 15 | 06/10/2023 | 08:43:26 | Memory #0x02 | Uncorrectable ECC (UnCorrectable ECC | DIMMA1) | Asserted 16 | 06/10/2023 | 08:45:16 | Unknown #0x2e | | Asserted 17 | 06/10/2023 | 08:45:16 | Memory #0x02 | Uncorrectable ECC (UnCorrectable ECC | DIMMA1) | Asserted 18 | 06/10/2023 | 08:45:16 | Memory #0x02 | Uncorrectable ECC (UnCorrectable ECC | DIMMB1) | Asserted
- 确认该事件是否缺少 DIMM。
命令:
# sudo dmidecode -t memory | grep "Locator\|Size" | grep -v "Cache\|Volatile\|Cache\|Logical\|Bank"
示例:
admin@node1:~> sudo dmidecode -t memory | grep "Locator\|Size" | grep -v "Cache\|Volatile\|Cache\|Logical\|Bank"
Size: No Module Installed <-- DIMM is missing
Locator: A1
Size: 16384 MB
Locator: A2
Size: No Module Installed
Locator: A3
Size: No Module Installed
Locator: A4
Size: No Module Installed
Locator: A5
Size: No Module Installed
Locator: A6
Size: No Module Installed
Locator: A7
Size: No Module Installed
Locator: A8
Size: 16384 MB
Locator: B1
Size: 16384 MB
Locator: B2
Size: No Module Installed
Locator: B3
Size: No Module Installed
Locator: B4
Resolution
收集上述命令的输出,并打开一个服务请求(引用 KB 215723以查看要更换的服务器 DIMM。
如果已成功更换 DIMM,则 xDoctor 版本 4.8.92.0 或更高版本需要清除受影响节点上的 SEL。它会停止对此日志条目发出进一步的警报。
如果已成功更换 DIMM,则 xDoctor 版本 4.8.92.0 或更高版本需要清除受影响节点上的 SEL。它会停止对此日志条目发出进一步的警报。
示例 — 清除系统事件日志 (SEL):
查询 iDRAC 以获取系统事件日志,并确认输出中存在错误。
请记住,在清除 SEL 之前,检查是否存在需要解决的任何其他错误。此外,将日志保存到 /var/log/hardware 如所述 KB 49569。
在此示例中,192.168.219.101对应于节点 1 的 iDRAC IP:
admin@provo~> ipmitool -I lanplus -H 192.168.219.101 -U root -P passwd sel list 1 | 01/06/2022 | 04:34:58 | Event Logging Disabled #0x72 | Log area reset/cleared | Asserted 2 | 02/03/2022 | 17:15:21 | Physical Security #0x73 | General Chassis intrusion () | Asserted 3 | 02/03/2022 | 17:15:28 | Physical Security #0x73 | General Chassis intrusion () | Deasserted 4 | 08/18/2023 | 01:44:01 | Memory #0x02 | Uncorrectable ECC (UnCorrectable ECC | DIMMA1) | Asserted
清除 SEL:
admin@provo:~> ipmitool -I lanplus -H 192.168.219.101 -U root -P passwd sel clear Clearing SEL. Please allow a few seconds to erase.
验证列表是否已清除:
admin@provo~> ipmitool -I lanplus -H 192.168.219.101 -U root -P passwd sel list 1 | 08/30/2023 | 12:56:55 | Event Logging Disabled #0x72 | Log area reset/cleared | Asserted
Affected Products
ECS Appliance Gen 3Products
ECS ApplianceArticle Properties
Article Number: 000215723
Article Type: Solution
Last Modified: 30 May 2024
Version: 7
Find answers to your questions from other Dell users
Support Services