Connectrix MDS: Temperature sensor shows status as unknown
Summary: The Connectrix MDS Temperature sensor shows the status as unknown.
This article applies to
This article does not apply to
This article is not tied to any specific product.
Not all product versions are identified in this article.
Symptoms
The temperature sensor shows Status unknown:
`show environment`
Temperature:
--------------------------------------------------------------------
Module Sensor MajorThresh MinorThres CurTemp Status
(Celsius) (Celsius) (Celsius)
--------------------------------------------------------------------
4 Crossbar0 (s1) 125 115 38 Ok
4 Crossbar1 (s2) 125 115 41 Ok
4 Arb-mux (s3) 125 105 35 Ok
4 CPU (s4) 125 105 46 Ok
4 PCISW (s5) 125 105 41 Ok
4 IOSlice0 (s6) 125 115 28 Ok
4 IOSlice1 (s7) 125 115 25 Ok
4 IOSlice2 (s8) 125 115 29 Ok
4 Sensor-12 -68 11 40 unknown enum:<1
This issue is seen on linecard DS-X9648-1536K9 when the switches are running on NX-OS 8.4(2c).
Cause
This issue is identified in Cisco Issue CSCwb85846 .
Resolution
Workaround:
To recover the sensor, run the following set of commands:
config t poweroff module no poweroff module
Resolution:
This issue is addressed in the NX-OS: 9.3(1) and 8.4(2e)
Products
Connectrix MDS-SeriesArticle Properties
Article Number: 000216223
Article Type: Solution
Last Modified: 18 Apr 2025
Version: 3
Find answers to your questions from other Dell users
Support Services
Check if your device is covered by Support Services.