Solution Builder Extensions for Azure Local -Integrated System AX Server Release Notes

Summary: This article provides information about Solution Builder Extensions (SBEs) for Azure Local. SBEs allow updates to Firmware, Driver, and Windows Defender Application Control (WDAC) supplemental policies for Azure Local clusters running on Dell AX servers. ...

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Instructions

Contents

 

Overview.. 1

Important Caveats. 2

New For This Release. 2

SBE 4.2.2509.1625. 2

SBE 4.2.2509.1516. 2

SBE 4.2.2509.1411. 2

Prerequisites. 2

Update Firmware and Drivers Prior to Azure Local Instance Deployment. 2

IDRAC Access from Host OS. 2

Manual iDRAC Access Verification. 3

Azure Local instances using Non-Transparent, Unauthenticated Network Proxy. 3

Download Connector – Automated download of future SBE release. 4

Overview.. 4

Firewall Requirements. 4

Installation. 5

Download and Extract. 5

Automated Download and Extraction. 5

Installing SBE as Part of Instance Creation. 5

Importing the SBE After Successful Azure Local Instance Creation. 5

Known Issues. 7

Previous Releases. 11

 

Overview

Solution Builder Extensions (SBE) for Azure Local provide firmware, driver, and WDAC supplemental policies for life-cycle management for Azure Local instances running on Dell AX servers.

 

SBE Release Version

Download links

Supported Servers

Driver and Firmware versions

HCI OS Version

Supported Solution Version

4.2.2509.1625

https://www.dell.com/support/home/en-us/drivers/driversdetails?driverid=CGKK0

 

AX-660

AX-760

 

 Azure Local Support Matrix for 16G (2509) | Solutions for Microsoft Azure

24H2

 

23H2

12.*.1002.*

12.*.1001.*

11.*.1002.*

11.*.1001.*

AX-4510C

AX-4520C

Azure Local Support Matrix for AX-4500 (2509) | Solutions for Microsoft AzureThis hyperlink is taking you to a website outside of Dell Technologies.

4.2.2509.1516

https://www.dell.com/support/home/en-us/drivers/driversdetails?driverid=DTM18

 

 

AX-650

AX-750

AX-6515

AX-7525

 

 Azure Local Support Matrix for 14G-15G (2509) | Solutions for Microsoft AzureThis hyperlink is taking you to a website outside of Dell Technologies.

 

24H2

 

23H2

12.*.1002.*

12.*.1001.*

11.*.1002.*

11.*.1001.*

 

4.2.2509.1411

https://www.dell.com/support/home/en-us/drivers/driversdetails?driverid=D5R9P

 

AX-640

AX-740xd

24H2

 

23H2

12.*.1002.*

12.*.1001.*

11.*.1002.*

11.*.1001.*

 

 

Important Caveats

  • NVIDIA ConnectX NIC Resets with driver version 25.1.26647.0: SBE version 4.2.2506 introduced ConnectX driver version 25.1.26647.0 and corresponding firmware. ConnectX NIC resets have been observed by customers under certain workloads. SBE 4.2.2509.n will downgrade the ConnectX driver to version 24.4.26429.0, but the ConnectX firmware must be manually downgraded prior to installing SBE 4.2.2509.n See KB000376360 for details and instructions.
  • Dell Micron 7450 and 7500 NVMe SSDs occasionally enter a panic state: Details are described in KB000368482. From the SBE table above, find the version relevant to your product. Install the SBE with updated firmware that resolves the defect for the Micron 7450 and 7500 drives.

New For This Release

 

SBE 4.2.2509.1625

  • Added support for solutions 11.*.1002.* and 12.*.1002.*
  • Driver and Firmware 2509 Update

SBE 4.2.2509.1516

  • Added support for solutions 11.*.1002.* and 12.*.1002.*
  • Driver and Firmware 2509 Update

SBE 4.2.2509.1411

  • Added support for solutions 11.*.1002.* and 12.*.1002.*
  • Driver and Firmware 2509 Update

 

Prerequisites

 

Update Firmware and Drivers Prior to Azure Local Instance Deployment

Drivers and firmware must be installed on servers that will be instance members prior to deploying the instance from the Azure Portal or using an ARM template. This requirement is independent of the SBE installation. The most current driver and firmware versions listed in the support matrix are recommended. The Azure Local support matrix for Dell AX servers is located at the following link:
Support Matrix | Solutions for Microsoft Azure Stack (dell.github.io)

 

IDRAC Access from Host Operating System

The iDRAC pass-through NIC must be enabled and have an IP address assigned to it. By default, the iDRAC pass-through NIC is enabled and has an APIPA address assigned. This IP address must be accessible by the “Remote NDIS Compatible Device” iDRAC NIC in the host operating system (OS). This is a dedicated link to the host OS and cannot be accessed outside of it.

 

IDRAC access health checks are introduced starting with December 2024 SBE releases. These health checks verify that that the required iDRAC access has been implemented on each server that is or will be an instance member. The iDRAC access health checks run automatically as part of the standard built-in SBE health checks. These health checks must complete successfully for SBE installation to proceed. Failure remediation instructions are provided if the health check fails.

 

Manual iDRAC Access Verification

 

The following procedures provide a manual method for verifying the required iDRAC access. The iDRAC access health checks provide an automated and more comprehensive verification method.

 
Example
iDRAC passthrough settings  
Figure 1: iDRAC passthrough settings

 


The “Remote NDIS Compatible Device” iDRAC NIC in the host OS is used by the SBE CAUPlug-in to update firmware. The DHCP client should not be disabled on this NIC.

 

The IP address of the iDRAC NIC can be obtained with the following PowerShell command:

Get-NetAdapter -InterfaceDescription "Remote NDIS Compatible Device" | Get-NetIPAddress -AddressFamily IPv4 | Select-Object IPAddress

 

Example output:

IPAddress

---------

169.254.0.2



Azure Local instances using Non-Transparent, Unauthenticated Network Proxy

Azure Local instances using non-transparent, unauthenticated network proxy must have the iDRAC pass-through IP address in the network proxy exclusion list. Configuring the non-transparent, unauthenticated network proxy is documented at the following link:

https://learn.microsoft.com/en-us/azure-stack/hci/manage/configure-proxy-settings-23h2#configure-proxy-settings-for-environment-variablesThis hyperlink is taking you to a website outside of Dell Technologies.

 

The following example shows how to configure the APIPA address range 169.254.0.0/16 to be in the network proxy exclusion list.

$no_proxy = "localhost,127.0.0.1,.svc,10.0.0.0/8,172.16.0.0/12,192.168.0.0/16,.contoso.com,node1,node2,ClusterName,169.254.0.0/16"

[Environment]::SetEnvironmentVariable("NO_PROXY", $no_proxy, "Machine")

 

Download Connector – Automated download of future SBE releases

 

Overview

The download connector is a component of the SBE that automates the downloading of new SBE bundles as they become available for the instance. Once an SBE that includes the download connector is installed on an instance, manually downloading and importing subsequent SBE versions is no longer required. The update service automates the downloading of the next available SBE for the instance in a manner similar to the automated download of the solution update. The download connector is part of SBE version 4.1.2505.1501 and newer.

SBE versions that include the download connector also include new system and update health checks. These checks proactively verify that the download connector can access the required remote resource when it is time to download the next SBE for the instance. System health checks are run once per day, and update health checks are run during the initial phase of the update process.

 

Firewall Requirements

The SBE download connector must periodically connect to Internet resources to download SBE bundles for the instance. The following outbound connectivity is required:

 

Endpoint Description

Endpoint URL

Port

SBE bundle download

dl.dell.com/*

443

SBE download catalog

downloads.dell.com/filestore/Prod/SbeDownloadCatalog/AX_SBE_Download_Catalog.xml

443

SBE download catalog redirection

aka.ms/DellAzureLocalSBEDownloadCatalog

443

Digicert certificate revocation status

http://crl3.digicert.com/*

80

Digicert certificate revocation status

http://crl4.digicert.com/*

80

 

Installation

 

Download and Extract

Important for this release: Steps 3 and 4 must be completed!

 

The SBE bundle file has the naming convention Bundle_SBE_Dell_AS-HCI-AX-GenerationNumber_VersionNumber.zip.

  1. Download the applicable SBE bundle using the download link above. SBE bundles are specific to the AX 15G and AX 16G platforms.
  2. Extract the three SBE files from the SBE bundle zip file. There are two xml files and one zip file. Example:
  • SBE_Dell_AS-HCI-AX-16G-45n0c _4.2.2506.1600.xml
  • SBE_Dell_AS-HCI-AX-16G-45n0c _4.2.2506.1600.zip
  • SBE_Discovery_Dell.xml
  1. Browse to this link and type Ctrl+S to download the SBE_Discovery_Dell.xml file:
    https://aka.ms/AzureStackSBEUpdate/DellEMCThis hyperlink is taking you to a website outside of Dell Technologies.
  2. Replace the SBE_Discovery_Dell.xml file in the SBE bundle with the file downloaded in step 3.

 

There are two options for installing the SBE package. The package can be installed as part of instance creation or imported after instance creation is successfully completed. The importing method is also used to update the SBE to a newer version when the current SBE does not include download connector capability.

 

Automated Download and Extraction

SBE releases starting with 4.1.2505.15n include the download connector that automates downloading and extracting the SBE. Manual download and SBE bundle extraction are unnecessary when an SBE with this capability is installed on the Azure Local instance. 

 

Installing SBE as Part of Instance Creation

Starting with June 2025 Dell golden image release, the SBE files are included in the golden image and already placed in the C:\SBE directory. The following three steps do not need to be performed.

  1. On each server that will be an instance member, create the following directory:
    C:\SBE
  2. Copy the three SBE files to the directory C:\SBE on each server that will be a instance member
  3. Proceed to deploying the instance from Azure Portal or ARM template

 

Importing the SBE After Successful Azure Local Instance Creation

  1. Create a directory on a cluster shared volume (CSV) for importing the SBE. 
    Example:
    C:\ClusterStorage\Infrastructure_1\SBE\SBE-AX-16G_4.1.2412.1202
  2. Copy the three extracted SBE files to this directory.
  3. Load the SBE files by running the following command, using the path to the directory containing the three extracted SBE files. 
    Example:
    Add-SolutionUpdate -SourceFolder C:\ClusterStorage\Infrastructure_1\SBE\SBE-AX-16G-45n0c _4.2.2506.1600
  4. Check the state of the SBE that was just added. The state must be “Ready” in order to proceed.
    Example:
    Get-SolutionUpdate | Where-Object PackageType -EQ "SBE"
  5. Verify that the Azure Local instance is in a healthy state and is ready for SBE installation by running the following commands on one of the Azure Local instance members: 
    Get-SolutionUpdate | Where-Object {$_.State -imatch "Ready" -and $_.PackageType -eq "SBE"}  | Sort-Object -Property ResourceID -Descending | Select-Object -First 1 | Start-SolutionUpdate -PrepareOnly
  6. Wait for the health check to finish. The solution update state will report “HealthChecking” while the health check is in progress.
  7. After the health check finishes, run the following command if the solution update state reports “HealthCheckFailed”:
    $result = (Get-SolutionUpdate | Where-Object {$_.State -imatch "Ready" -and $_.PackageType -eq "SBE"} | Sort-Object -Property ResourceID -Descending | Select-Object -First 1).HealthCheckResult 
    
    $result | Where-Object {($_.Status -ne "SUCCESS" -and $_.Severity -eq "CRITICAL" )} | Format-List Title, Status, Severity, Description, Remediation, TargetResourceName, TargetResourceType

    Ensure that all tests with “Critical” severity have the “Success” status before continuing to the next step.

  8. Start the SBE installation by running the following command.
    Get-SolutionUpdate | Where-Object {$_.State -imatch "Ready" -and $_.PackageType -eq "SBE"} | Sort-Object -Property ResourceID -Descending | Select-Object -First 1 | Start-SolutionUpdate
  9. The SBE installation progress can be checked with the following command:
    Get-SolutionUpdate | Where-Object PackageType -EQ "SBE" | Format-List ResourceID, Description, State, SBEVersion, UpdateStateProperties, HealthState

See the following link for more information: https://learn.microsoft.com/en-us/azure/azure-local/update/update-via-powershell-23h2?view=azloc-24113#step-3-import-and-rediscover-updatesThis hyperlink is taking you to a website outside of Dell Technologies.

 

Known Issues

 

Updating Secure Boot component firmware may result in Azure Local registration connection status “Repair Registration Required” when the Azure Local instance is running Solution 10.2503 or newer

 

Description

Updating Secure Boot component firmware, such as the BIOS, can lead to loss of Azure registration. When this occurs, the Get-AzureStackHCI command shows a connection status of RepairRegistrationRequired.

 

Background

Azure Local Solution 10.2503 includes mitigation for the Secure Boot bypass vulnerability described in CVE-2023-24932This hyperlink is taking you to a website outside of Dell Technologies.. This mitigation is documented at the link below.

How to manage the Windows Boot Manager revocations for Secure Boot changes associated with CVE-2023-24932 - Microsoft SupportThis hyperlink is taking you to a website outside of Dell Technologies.

 

Workaround

This link includes instructions for validating this issue and repairing the Azure registration:

https://github.com/Azure/AzureLocal-Supportability/blob/main/TSG/Update/BreakFix-Update-Resolve-subscription-status-precheck-failure.mdThis hyperlink is taking you to a website outside of Dell Technologies.

 

In versions prior to 2505, cumulative OS updates may be unexpectedly installed on the third Tuesday of the month

 

Description
If the most recently installed update includes an SBE update, cumulative OS updates may be automatically scheduled to install. These cumulative updates are installed on the third Tuesday of each month, beginning at 3am local time. This causes the installed OS version to be newer than the installed Azure Local solution version.
 
Background
If an SBE uses a CAU plugin which runs the Set-CauClusterRole -CauPluinName $null -Force command, the DaysOfWeek and WeeksOfMonth attributes are added to CauClusterRole. These attributes cause the behavior described above.
 
Validation
To confirm that an Azure Local instance is affected by this issue, run Get-CauClusterRole. If the output shows the DaysOfWeek and WeeksOfMonth attributes, with values of Tuesday and 3 respectively, the issue is present. Depending on when the issue is detected, cumulative OS updates may not have been installed yet.

Workaround

A detailed workaround can be found in the Microsoft documentation at the following link:

https://github.com/Azure/AzureLocal-Supportability/blob/main/TSG/Update/OS-update-automatically-set-to-run-on-3rd-Tuesday-following-SBE-update.mdThis hyperlink is taking you to a website outside of Dell Technologies.

 

Important: The workaround must be performed each time an SBE update is installed, until solution version 11.2505.x or newer is installed.
 

Partially installed SBE version 4.0.0.0 is shown when SBE is installed as part of cluster deployment


Description

Get-SolutionUpdateEnvironment reports a partially installed SBE when installing the SBE as part of instance deployment. SBE version 4.0.0.0, shown below, indicates a partially installed SBE.

Get-SolutionUpdateEnvironment

ResourceId        : redmond
SbeFamily         : AS-HCI-AX
HardwareModel     : AX-750
LastChecked       : 5/9/2024 12:17:11 AM
PackageVersions   : {Solution: 10.2405.0.23, Services: 10.2405.0.23, Platform: 1.0.0.0, SBE: 4.0.0.0}
CurrentVersion    : 10.2405.0.23
CurrentSbeVersion : 4.0.0.0
LastUpdated       :
State             : AppliedSuccessfully
HealthState       : Success
HealthCheckResult : {Storage Services Physical Disks Summary, Storage Services Physical Disks Summary, Storage
                    Services Physical Disks Summary, Storage Services Physical Disks Summary...}
HealthCheck Date   : 5/25/2024 11:50:35 PM
AdditionalData    : {[SBEAdditionalData, Solution Builder extension is partially installed. Please install the latest
                    Solution Builder Extension provided by your hardware vendor.


Workaround
Reinstall the same SBE version using the SBE import method after instance deployment successfully finishes.


Background

The SBE CAUPlug-in driver expects all drivers in the SBE payload to be installed on the server during deployment. However, some of the drivers in the SBE payload may not apply to the server model or components in the server model. Microsoft is aware of the limitation and is working to resolve this issue in a future release.

 

SBE installation does not downgrade drivers that have a newer version than the same driver in the SBE payload


Description

The SBE CAUPlug-in driver does not attempt to downgrade installed drivers that are more recent than the ones in its payload.

Dell supports the driver and firmware versions listed here: Support Matrix | Solutions for Microsoft AzureThis hyperlink is taking you to a website outside of Dell Technologies.

 

SBE packages prior to versions 4.2.2506.1506 and 4.2.2506.1404 do not include the Intel X710 driver in the payload


Description

The SBE CAUPlug-in driver is unable to update the X710 driver because the X710 driver cannot be updated using PNPUtil /Add-driver.

The following command shows the driver version used by the Intel X710 NIC.

Get-NetAdapter -InterfaceDescription *X710* | Format-List Name, DriverInformation


Workaround

  1. Download the Intel X710 NIC DUP driver package (Network_Driver_6JHVK_WN64_23.0.0_A00.EXE) from the Dell Support site: https://www.dell.com/support/home/drivers/driversdetails?driverid=6JHVK
  2. Copy Network_Driver_6JHVK_WN64_23.0.0_A00.EXE to each instance member.
  3. Place one server at a time into maintenance mode and move the virtual machines running on that server to other instance members:
    Suspend-ClusterNode -Name <NodeName> -drain
  4. Run Network_Driver_6JHVK_WN64_23.0.0_A00.EXE on that server to install the driver. Allow the server to reboot if necessary.
  5. Verify the driver version used by the Intel X710 NIC is version 1.19.165.0 and has the date April 05, 2024 by running the following command again:
    Get-NetAdapter -InterfaceDescription *X710* | Format-List Name, DriverInformation
  6. Take the server out of maintenance mode and move the virtual machines back to it:
    Resume-ClusterNode -Name <NodeName> -Failback
  7. Repeat this procedure for each member of the Azure Local instance.

Install the SBE package once all instance members are using the required X710 driver.

 

Error event RED149 in iDRAC Lifecycle log after CPLD firmware update


Description

The following error-level event may be logged in the iDRAC Lifecycle log after updating CPLD firmware 

Message         : Unable to create the job because a CPLD firmware job and non-CPLD job cannot be performed at the  same time.
MessageId       : IDRAC.2.9.RED149


Workaround

This error can be safely ignored.

 

Previous Releases

 

Platform

SBE Bundle Version

Firmware And Driver Payload

Download URL

AX 16G-45n0c

4.2.2506.1600

June 2025 Driver and Firmware Update

https://www.dell.com/support/home/en-us/drivers/driversdetails?driverid=8D3FF

AX 15G

4.1.2506.1506

June 2025 Driver and Firmware Update

https://www.dell.com/support/home/en-us/drivers/driversdetails?driverid=P4WF9

 

AX 14G

4.1.2506.1404

June 2025 Driver and Firmware Update

https://www.dell.com/support/home/en-us/drivers/driversdetails?driverid=9F1W7

AX 15G

4.1.2505.1503

March 2025 Driver and Firmware Update

https://www.dell.com/support/home/en-us/drivers/driversdetails?driverid=W0R1F

AX 16G-45n0c

4.1.2505.1504

March 2025 Driver and Firmware Update

https://www.dell.com/support/home/en-us/drivers/driversdetails?driverid=149T3

AX 15G

4.1.2505.1501

March 2025 Driver and Firmware Update

https://www.dell.com/support/home/en-us/drivers/driversdetails?driverid=C5Y7V

AX 16G-45n0c

4.1.2505.1502

March 2025 Driver and Firmware Update

https://www.dell.com/support/home/en-us/drivers/driversdetails?driverid=60GPP

AX 15G

4.1.2503.3101

March 2025 Driver and Firmware Update

https://www.dell.com/support/home/en-us/drivers/driversdetails?driverid=M13VT

AX 16G

4.1.2503.3102

March 2025 Driver and Firmware Update

https://www.dell.com/support/home/en-us/drivers/driversdetails?driverid=T5K74

AX 15G

4.1.2412.1201

December 2024 Driver and Firmware Update

https://www.dell.com/support/home/en-us/drivers/driversdetails?driverid=XG1TT

AX 16G

4.1.2412.1202

December 2024 Driver and Firmware Update

https://www.dell.com/support/home/en-us/drivers/driversdetails?driverid=PPH7R

AX 15G

4.1.2410.901

September 2024 Driver and Firmware Update

https://www.dell.com/support/home/en-us/drivers/driversdetails?driverid=XNYNG

AX 16G

4.1.2409.1501

September 2024 Driver and Firmware Update

https://www.dell.com/support/home/en-tc/drivers/driversdetails?driverid=6t8nt

AX 15G

4.1.2406.3001

June 2024 Driver and Firmware Update

https://www.dell.com/support/home/en-tc/drivers/driversdetails?driverid=6k6g3

AX 15G

4.1.2405.2001

March 2024 Driver and Firmware Update

https://www.dell.com/support/home/en-tc/drivers/driversdetails?driverid=5WH4H

 

 

 

 

Affected Products

AX Nodes, AX-4510C, AX-4520C, ax-650, AX-6515, AX-660, AX-750, AX-7525, AX-760
Article Properties
Article Number: 000224407
Article Type: How To
Last Modified: 03 Nov 2025
Version:  53