Connectrix: Brocade: Unable to HAreboot while firmware upgrade
Summary: Switch is showing an error while upgrading the firmware to 8.2.3e2 on DS-6520B switch.
This article applies to
This article does not apply to
This article is not tied to any specific product.
Not all product versions are identified in this article.
Symptoms
Error message:
Can't do hareboot because system is not ready yet or other LS/HA config is in progress, rc = -1
This error was seen when the Standby partition was upgraded to 8.2.3e2 and above to perform hareboot.
Manual hareboot of the switch and starting the firmware upgrade again did not help.
Cause
Possible cause:
1) High CPU usage
2) High Memory usage
Resolution
-- Reboot of switch and perform the firmware upgrade once switch is online.
NOTE: Precautions as the reboot are disruptive:
1) Initiate a downtime.
2) Validate the Multipathing on all the Hosts accessing the switch
3) Take a configuration back-up from the switch.
Affected Products
Brocade 6505, Connectrix DS 6510B, Connectrix DS 6520BArticle Properties
Article Number: 000308747
Article Type: Solution
Last Modified: 18 Apr 2025
Version: 1
Find answers to your questions from other Dell users
Support Services
Check if your device is covered by Support Services.