Connectrix: Card is offline
Summary: Ports on MOD_Val
This article applies to
This article does not apply to
This article is not tied to any specific product.
Not all product versions are identified in this article.
Symptoms
Ports in a card are stuck on MOD_VAL
disabling and enabling the port does not work.
There is a known defect on 9.2.X causing this. hareboot / hafailover is needed.
Related brocade case 2224635
Cause
Known 9.2 defect.
FOS-846314 SfpShow indicating "Media not installed" and switchShow showing a port state of "Mod_Val"
Its documented in the FOS 9.2 Release Notes
Resolution
hareboot / hafailover fixes the problem