CloudIQ: Unable to request a code with the current Dell EMC Customer support credentials
概要: The above error may occur when a CloudIQ Collector is being configured to an integrated gateway.
この記事は次に適用されます:
この記事は次には適用されません:
この記事は、特定の製品に関連付けられていません。
すべての製品パージョンがこの記事に記載されているわけではありません。
現象
Customer is attempting to configure a CloudIQ Collector to an integrated gateway using the following procedure:
Collecting the Diagnostic file shows the following ERROR within the provisioning log (hostmnt_log > var > log > esrs).
"PKIX path building failed"
- Power on the CloudIQ Collector.
- Login to the CloudIQ Collector.
- Select Admin > Settings and the Integrated Gateway tab.
- Plug in the Dell EMC user account (email) and password (no special characters) and click on Start Provisioning.
- No proxy direct connection – leave off unless required.
- It then verifies the user account (email) and asks the customer to request an access code.
- Once the code is received the customer would then plug this in and select a site ID that is also verified.
- The integrated gateway (ISWID) is then created and the CIQ Collector is created (SWID) and placed under the gateway to be managed.
Collecting the Diagnostic file shows the following ERROR within the provisioning log (hostmnt_log > var > log > esrs).
"PKIX path building failed"
原因
Customer is utilizing an SSL interceptor or transparent proxy within their network. This will substitute the certificate authority and crack the inscription causing the issue.
解決方法
Options:
- Customer can enter in an exception or exclusion for the SSL interceptor (or transparent proxy) application to continue using the CloudIQ Collector’s eVE configuration.
- Customer can install a new centralized gateway and configure the CloudIQ Collector to it. The centralized gateway being used would also need an exception or exclusion for the SSL interceptor (or transparent proxy) application. This would need to be addressed by the customer and/or the customer’s network team in the same manner as in option 1 above.
その他の情報
Exceptions/exclusions must be made using a third party tool or the SSL interceptor or proxy application outside of Secure Connect Gateway (SCG).
Customers may exclude *.emc.com to cover all the domains or list each separately.
● The local system must be able to connect to the following Enterprise servers through ports 443 and 8443:
- esrs3-core.emc.com
- esrs3-coredr.emc.com
● The local system must be able to connect to the following Global access servers through ports 443 and 8443:
- esr3gduprd01.emc.com
- esr3gduprd02.emc.com
- esr3gduprd03.emc.com
- esr3gduprd04.emc.com
- esr3gduprd05.emc.com
- esr3gduprd06.emc.com
- esr3ghoprd01.emc.com
- esr3ghoprd02.emc.com
- esr3ghoprd03.emc.com
- esr3ghoprd04.emc.com
- esr3ghoprd05.emc.com
- esr3ghoprd06.emc.com
- esr3gscprd01.emc.com
- esr3gscprd02.emc.com
- esr3gscprd03.emc.com
- esr3gscprd04.emc.com
- esr3gscprd05.emc.com
- esr3gscprd06.emc.com
- esr3gckprd01.emc.com
- esr3gckprd02.emc.com
- esr3gckprd03.emc.com
- esr3gckprd04.emc.com
- esr3gckprd05.emc.com
- esr3gckprd06.emc.com
- esr3gckprd07.emc.com
- esr3gckprd08.emc.com
- esr3gckprd09.emc.com
- esr3gckprd10.emc.com
- esr3gckprd11.emc.com
- esr3gckprd12.emc.com
- esr3gspprd01.emc.com
- esr3gspprd02.emc.com
- esr3gspprd03.emc.com
- esr3gspprd04.emc.com
- esr3gspprd05.emc.com
- esr3gspprd06.emc.com
- support.emc.com