Summary: This article provides guidance for resolving the ADS0005 error encountered during the discovery of a PowerProtect Data Domain (DD) system in PowerProtect Data Manager. A misconfigured login session limit on the DD system causes the error by preventing the generation of a valid authentication token. ...
Acest articol se aplică pentru
Acest articol nu se aplică pentru
Acest articol nu este legat de un produs specific.
Acest articol nu acoperă toate versiunile de produs existente.
Symptoms
During the discovery of a PowerProtect DD system in PowerProtect Data Manager, the following error is displayed:
ADS0005 Unable to discover protection storage PowerProtect DD System with address <n.n.n.n> because of com.emc.brs.common.resource.ResourceException: Error while executing /rest/v1.0/systemcode: 5468 statusCode: 400 Error: **** Authentication token is empty..
Cause
The error occurs when the login-max-active option on the Data Domain system is set too low, preventing PowerProtect Data Manager from establishing a valid session and retrieving the required authentication token.
To verify the current setting, run:
# adminaccess option show login-max-active
Resolution
To address the issue:
- Log in to the Data Domain system using CLI.
- Increase the maximum number of active login sessions by running:
# adminaccess option set login-max-active 100
- Retry the discovery operation from the PowerProtect Data Manager user interface.
This change sets the login-max-active value to its default, allowing PowerProtect Data Manager to successfully authenticate and complete the discovery process.