NetWorker Virtualization: VM Backup is failing with Error "Backup has FAILED. Unable to open previous backup."
Сводка: VM Backup is failing with Error: Backup has failed: Backup has FAILED. Unable to open previous backup. Failed to load version 1 backup descriptor from file '/path/Backup targets/BackupDescriptor.json': Failed to read JSON encoding from input stream: [5040] calling system(), returns nonzero ...
Данная статья применяется к
Данная статья не применяется к
Эта статья не привязана к какому-либо конкретному продукту.
В этой статье указаны не все версии продуктов.
Симптомы
Error Message:
Backup has failed: Backup has FAILED. Unable to open previous backup. Failed to load version 1 backup descriptor from file '/path to backup targets/42/61/cf4ce8c5-00000006-1564ebb4-6464ebb4-77ec5000-4975b756/BackupDescriptor.json': Failed to read JSON encoding from input stream: [5040] calling system(), returns nonzero
Location: Go to NMC > Monitoring tab > Select the Dedicated Policy & Workflow in which that particular VM is failing > Double-click to Open > Click on Show message logs > Copy the entire logs and paste in to a notepad file.
Причина
- Due to Vproxy being stopped responding and it must be killed or restarted properly.
- Due to the ESXI host being unable to capture the backup as there is much of load on it and this leads the ESXI to go in not responding state or Stale ESXI (i.e, Not Working Properly).
- When the backup workflow was using the "PreviousBackupPath" and the "CurrentBackupPath" devices on different mtree's the backup would fail. If the backup workflow was using the "PreviousBackupPath" and the "CurrentBackupPath" devices on the same mtree, the backups would complete successfully. The target backup pool must contain devices from the same Data Domain, but it is supported to have the devices in different mtree's.
Разрешение
Action Plan:
Option A:
- Ensure that the Data Domain devices are properly configured in the environment. If required, create a new target backup pool with devices under the same Data Domain mtree.
- Rebooting the vProxies and in some cases the ESXi also must be rebooted in order to resolve the issue.
Option B:
>>Login to NMC, If backup is failed with the above mentioned error message.->Must go to Protection tab, Then Policies.
->Choose the dedicated Workflow.
->Change the Configuration to Full and then configure it.
->Post doing the above, Kindly trigger the VM by start Individual client.
->Post triggering as Full, revert back to the Configuration to how it was earlier.
Most probably, Backup will be Successful after the above action plan.
Дополнительная информация
Please see below two cases where the resolution did worked,
Cases: SR#128403734, SR#107428962
Свойства статьи
Номер статьи: 000214585
Тип статьи: Solution
Последнее изменение: 30 Aug 2023
Версия: 5
Получите ответы на свои вопросы от других пользователей Dell
Услуги технической поддержки
Проверьте, распространяются ли на ваше устройство услуги технической поддержки.