Přeskočit na hlavní obsah
  • Vkládejte objednávky snadno a rychle
  • Zobrazit objednávky a sledovat stav expedice
  • Vytvořte a přistupujte k seznamu svých produktů
  • Spravujte své profily, produkty a kontakty na úrovni produktů na stránkách Dell EMC pomocí správy společnosti.

Dell PowerEdge R730 Owner's Manual

Removing a DC power supply unit

Prerequisites

NOTE: For equipment using –(48–60) V DC power supply units (PSUs), a qualified electrician must perform all connections to DC power and to safety grounds. Do not attempt connecting to DC power or installing grounds yourself. All electrical wiring must comply with applicable local or national codes and practices. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow all safety instructions that came with the product.
CAUTION: The system needs one power supply for normal operation. On power-redundant systems, remove and replace only one power supply at a time in a system that is powered on.
NOTE: You may have to unlatch and lift the optional cable management arm if it interferes with power supply removal. For information about the cable management arm, see the rack documentation of your system.

Steps

  1. Disconnect the power wires from the power source and the connector from the PSU you intend to remove.
  2. Disconnect the safety ground wire.
  3. Press the release latch and slide the PSU out of the chassis by using the PSU handle.
    Figure 1. Removing a DC PSU
    This figure shows removing a DC PSU.
    1. release latch
    2. power supply status indicator
    3. PSU
    4. power connector
    5. PSU handle