Brings the interface up or down when a Remote Fault Indication (RFI) error is detected.

Syntax remote-fault-signaling rx {on | off}
Parameters
on Brings the interface up when an RFI error is detected.
off Brings the interface down when an RFI error is detected.
Defaults ON.
Command Modes INTERFACE CONFIGURATION
Supported Modes Full–Switch
Command History
Version Description
9.9(0.0) Introduced on the FN IOM.
9.7(0.0) Introduced on the MXL switch.
Usage Information

By default, the switch processes the RFI errors transmitted by remote peers and brings down the interface when an RFI error is detected.

Example
Dell(conf-if-te-1/3)#remote-fault-signaling rx ?
                                             on Enable
                                             off Disable
                                          