Dell PowerEdge FN I/O Module Command Line Reference Guide 9.10(0.0)

PDF

tagged

Add a Layer 2 interface to a VLAN as a tagged interface.

Syntax tagged interface

To remove a tagged interface from a VLAN, use the no tagged interface command.

Parameters
interface Enter the following keywords and slot/port or number information:
  • For a Port Channel interface, enter the keywords port-channel then a number. The range is from 1 to 128.
  • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port information.
Defaults All interfaces in Layer 2 mode are untagged.
Command Modes INTERFACE VLAN
Supported Modes Full–Switch
Command History
Version Description
9.9(0.0) Introduced on the FN IOM.
8.3.16.1 Introduced on the MXL 10/40GbE Switch IO Module.
Usage Information

When you use the no tagged command, the interface is automatically placed in the Default VLAN as an untagged interface unless the interface is a member of another VLAN. If the interface belongs to several VLANs, remove it from all VLANs to change it to an untagged interface.

Tagged interfaces can belong to multiple VLANs, while untagged interfaces can only belong to one VLAN at a time.

Related Commands

interface vlan — configures a VLAN.

untagged — specifies which interfaces in a VLAN are untagged.