The
EGW-5200 provides four COM ports through D-sub 9-pin connectors. The COM1 and COM2 ports support RS-232/422/485 modes by BIOS setting, while COM3 and COM4 are located on the uFM modules and support only RS- 232.
Table 1. D-Sub 9-pin signal function of COM portsD-Sub 9-pin signal function of COM ports
Pin
Signal
RS-232
RS-422
RS-485
1
DCD#
TXD422–
485DATA–
2
RXD
TXD422+
485DATA+
3
TXD
RXD422+
N/S
4
DTR#
RXD422–
N/S
5
GND
N/S
N/S
6
DSR#
N/S
N/S
7
RTS#
N/S
N/S
8
CTS#
N/S
N/S
9
RI#
N/S
N/S
Table 2. RS232 COM1 and COM2 specificationsRS232 COM1 and COM2 specifications
Parameter
Min
Typ
Max
Units
Note
Baud rate
–
–
115,200
bps
–
VO
±5
±5.5
–
V
No load = ±7 V max
VIH
1.8
2.4
V
–
VIL
0.8
1.5
–
V
–
Receiver input impedance
3,000
–
7,000
ohm
–
Load capacitance
–
–
2,500
pF
Includes receiver input
Slew rate
–
–
30
V/us
–
Table 3. RS422 COM1 and COM2 specificationsRS422 COM1 and COM2 specifications
Parameter
Min
Typ
Max
Units
Note
Baud rate
–
–
115,200
bps
–
VOD
2
–
5
V
RL = 100 ohm
VIH
–
–
10
V
–
VIL
–200
–
–50
mV
–
Receiver input resistance
–
–
4,000
ohm
–
Table 4. RS485 COM1 and COM2 specificationsRS485 COM1 and COM2 specifications
Parameter
Min
Typ
Max
Units
Note
Baud rate
–
–
115200
bps
–
VOD
1.5
–
5
V
RL = 54 ohm
VIH
–
–
10
V
–
VIL
–200
–
–50
mV
–
Receiver input resistance
–
–
12,000
ohm
–
Table 5. RS232 COM3 and COM4 specificationsRS232 COM3 and COM4 specifications
Parameter
Min
Typ
Max
Units
Note
Baud rate
–
–
115,200
bps
–
VO
±5
±9
–
V
All transmitter outputs loaded with 3 kΩ to ground
Output resistance 300 Ω VCC = 0 V, VOUT = ±2 V
VIH
–
2
2.4
V
TA = 0°C to 85°C
VIL
0.8
1.3
–
V
Receiver input impedance
3
5
7
Kohm
Load capacitance
50
–
2,500
Pf
Between the clamp and the cable
Slew rate
–
8
–
V/us
–
Data is not available for the Topic
Please provide ratings (1-5 stars).
Please provide ratings (1-5 stars).
Please provide ratings (1-5 stars).
Please select whether the article was helpful or not.
Comments cannot contain these special characters: <>()\