Chassis Alert 2

Table 1. DRsCA2MessageID
Name drsCA2MessageID
Object ID 1.3.6.1.4.1.674.10892.2.21.10.1
Description Defines the message ID of the alert.
Syntax DisplayString
Access Read-only
Table 2. DrsCA2Message
Name drsCA2Message
Object ID 1.3.6.1.4.1.674.10892.2.21.10.2
Description Defines the message describing the alert.
Syntax DellString
Access Read-only
Table 3. DrsCA2MessageArgs
Name drsCA2MessageArgs
Object ID 1.3.6.1.4.1.674.10892.2.21.10.3
Description Defines the concatenated set of strings that represent the message arguments that are used to construct the alert message. The message argument strings are enclosed within double quotes and are separated with a comma. Double quotes used within the message argument strings are preprocessed and changed to single quotes.
Syntax DellString
Access Read-only
Table 4. DrsCA2AlertStatus
Name drsCA2AlertStatus
Object ID 1.3.6.1.4.1.674.10892.2.21.10.4
Description Defines the status of the alert.
Syntax DellStatus
Access Read-only
Table 5. DrsCA2FQDD
Name drsCA2FQDD
Object ID 1.3.6.1.4.1.674.10892.2.21.10.5
Description Defines the fully qualified device descriptor of device causing the alert.
Syntax DisplayString
Access Read-only