Skip to main content
  • Place orders quickly and easily
  • View orders and track your shipping status
  • Enjoy members-only rewards and discounts
  • Create and access a list of your products
  • Manage your Dell EMC sites, products, and product-level contacts using Company Administration.

Event and Error Message Reference Guide for 13th Generation Dell PowerEdge ServersVersion 1.2

PDF

PSU Event Messages

PSU0000

Message
Power supply arg1 is present.
Arguments
arg1 = number
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health (PSU = Power Supply)
Severity
Severity 3 (Informational)
Trap/EventID
2187
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC ✔*  
CMC      
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*            

PSU0001

Message
Power supply arg1 failed.
Arguments
arg1 = number
Detailed Description
None
Recommended Response Action
Remove and re-install the power supply. If the issue persists, contact technical support. Refer to the product documentation to choose a convenient contact method.
Category
System Health (PSU = Power Supply)
Severity
Severity 1 (Critical)
Trap/EventID
2185
LCD Message
PSU <number> failed. Check PSU
OMSA Event ID
5300
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC ✔*  
CMC      
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*    
CMC ✔*            

PSU0002

Message
A predictive failure detected on power supply arg1 .
Arguments
arg1 = number
Detailed Description
System performance and power redundancy may be degraded or lost.
Recommended Response Action
Remove and re-install the power supply at the next service window. If the issue persists, contact technical support. Refer to the product documentation to choose a convenient contact method.
Category
System Health (PSU = Power Supply)
Severity
Severity 2 (Warning)
Trap/EventID
2186
LCD Message
Predictive failure on PSU <number>. Check PSU
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC ✔*  
CMC      
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*    
CMC ✔*            

PSU0003

Message
The power input for power supply arg1 is lost.
Arguments
arg1 = number
Detailed Description
The power supply is installed correctly but an input source is not connected or is not functional.
Recommended Response Action
Verify the input source is attached to the power supply. Verify the input power is within the operating requirements for the power supply.
Category
System Health (PSU = Power Supply)
Severity
Severity 1 (Critical)
Trap/EventID
2185
LCD Message
Power input for PSU <number> is lost. Check PSU cables
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC ✔*  
CMC      
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*    
CMC ✔*            

PSU0004

Message
The power input for power supply arg1 is outside of range.
Arguments
arg1 = number
Detailed Description
The operating requirements for the power supply may be found in product documentation or on the power supply itself.
Recommended Response Action
Verify the input source is attached to the power supply. Verify the input power is within the operating requirements for the power supply.
Category
System Health (PSU = Power Supply)
Severity
Severity 1 (Critical)
Trap/EventID
2185
LCD Message
Power input for PSU <number> is outside of range. Check PSU cables
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC ✔*  
CMC      
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*    
CMC ✔*            

PSU0005

Message
The power input for power supply arg1 is outside of the allowable range, but it is attached to the system.
Arguments
arg1 = number
Detailed Description
The operating requirements for the power supply may be found in product documentation or on the power supply itself.
Recommended Response Action
Verify the input power is within the operating requirements for the power supply.
Category
System Health (PSU = Power Supply)
Severity
Severity 2 (Warning)
Trap/EventID
2186
OMSA Event ID
5353
OMSA Trap ID
5353
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC ✔*  
CMC      
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*    
CMC ✔*            

PSU0006

Message
Power supply arg1 is incorrectly configured.
Arguments
arg1 = number
Detailed Description
The power supply identified in the message must be supported by the platform. Generally, multiple power supplies in the server should have the same feature set and power rating.
Recommended Response Action
Review server product documentation for supported power supplies and power supply configurations.
Category
System Health (PSU = Power Supply)
Severity
Severity 1 (Critical)
Trap/EventID
2185
LCD Message
Power supply <number> is incorrectly configured. Check PSU.
OMSA Event ID
5354
OMSA Trap ID
h
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC ✔*  
CMC      
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*    
CMC ✔*            

PSU0007

Message
Power supply arg1 is operating at 110 volts, and could cause a circuit breaker fault.
Arguments
arg1 = number
Detailed Description
A power supply that is designed to operate at 220V, but is connected to a 110V power source requires additional current for operation. The additional current may trip circuit-breakers or cause other electrical issues with the input source.
Recommended Response Action
Check input power source and cabling. Use recommended input power. Review the product documentation. If the issue persists, contact technical support. Refer to the product documentation to choose a convenient contact method.
Category
System Health (PSU = Power Supply)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC            
CMC            
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*            

PSU0017

Message
Power supply arg1 is operating normally.
Arguments
arg1 = number
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health (PSU = Power Supply)
Severity
Severity 3 (Informational)
Trap/EventID
2187
OMSA Event ID
5352
OMSA Trap ID
5352
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC ✔*  
CMC      
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*            

PSU0019

Message
The input power for power supply arg1 has been restored.
Arguments
arg1 = number
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health (PSU = Power Supply)
Severity
Severity 3 (Informational)
Trap/EventID
2187
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC ✔*  
CMC      
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*            

PSU0022

Message
Power supply arg1 is correctly configured.
Arguments
arg1 = number
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health (PSU = Power Supply)
Severity
Severity 3 (Informational)
Trap/EventID
2187
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC ✔*  
CMC      
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*            

PSU0023

Message
Power supply arg1 operating at 110 volts has been acknowledged by user.
Arguments
arg1 = number
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health (PSU = Power Supply)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC            
CMC            
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*            

PSU0031

Message
Cannot communicate with power supply arg1 .
Arguments
arg1 = number
Detailed Description
The power supply may operate, however power supply monitoring will be degraded. System performance may be degraded.
Recommended Response Action
Remove and re-install the power supply. If the issue persists, contact technical support. Refer to the product documentation to choose a convenient contact method.
Category
System Health (PSU = Power Supply)
Severity
Severity 1 (Critical)
Trap/EventID
2185
LCD Message
Cannot communicate with PSU <number>. Reseat PSU.
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC ✔*  
CMC      
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*    
CMC ✔*           ✔*

PSU0032

Message
The temperature for power supply arg1 is in a warning range.
Arguments
arg1 = number
Detailed Description
System performance may be degraded.
Recommended Response Action
Check the system operating environment, including airflow and inlet temperature. Check system logs for temperature and thermal component failures.
Category
System Health (PSU = Power Supply)
Severity
Severity 2 (Warning)
Trap/EventID
2186
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC ✔*  
CMC      
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*    
CMC ✔*           ✔*

PSU0033

Message
The temperature for power supply arg1 is outside of range.
Arguments
arg1 = number
Detailed Description
System performance may be degraded.
Recommended Response Action
Check the system operating environment, including airflow and inlet temperature. Check system logs for temperature and thermal component failures.
Category
System Health (PSU = Power Supply)
Severity
Severity 1 (Critical)
Trap/EventID
2185
LCD Message
PSU <number> temperature outside of range. Check PSU
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC ✔*  
CMC      
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*    
CMC ✔*           ✔*

PSU0034

Message
An under voltage fault detected on power supply arg1 .
Arguments
arg1 = number
Detailed Description
This failure may be the result of an electrical issue with cables or subsystem components in the system.
Recommended Response Action
1) Remove and re-install the power supply. 2) Check cables and subsystem components in the system for damage. 3) If the issue persists, contact technical support. Refer to the product documentation to choose a convenient contact method.
Category
System Health (PSU = Power Supply)
Severity
Severity 1 (Critical)
Trap/EventID
2185
LCD Message
An under voltage fault detected on PSU <number>. Check power source.
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC ✔*  
CMC      
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*    
CMC ✔*           ✔*

PSU0035

Message
An over voltage fault detected on power supply arg1 .
Arguments
arg1 = number
Detailed Description
None
Recommended Response Action
Check input power, replace or re-install the power supply. If the issue persists, contact technical support. Refer to the product documentation to choose a convenient contact method.
Category
System Health (PSU = Power Supply)
Severity
Severity 1 (Critical)
Trap/EventID
2185
LCD Message
Over voltage fault on PSU <number>. Check PSU
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC ✔*  
CMC      
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*    
CMC ✔*           ✔*

PSU0036

Message
An over current fault detected on power supply arg1 .
Arguments
arg1 = number
Detailed Description
This failure may be the result of an electrical issue with cables or subsystem components in the system.
Recommended Response Action
1) Remove and re-install the power supply. 2) Check cables and subsystem components in the system for damage. 3) If the issue persists, contact technical support. Refer to the product documentation to choose a convenient contact method.
Category
System Health (PSU = Power Supply)
Severity
Severity 1 (Critical)
Trap/EventID
2185
LCD Message
An over current fault detected on PSU <number>. Check PSU.
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC ✔*  
CMC      
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*    
CMC ✔*           ✔*

PSU0037

Message
Fan failure detected on power supply arg1 .
Arguments
arg1 = number
Detailed Description
None
Recommended Response Action
Check for fan blockage. If not replace the power supply.
Category
System Health (PSU = Power Supply)
Severity
Severity 1 (Critical)
Trap/EventID
2185
LCD Message
Fan failure detected on PSU <number>. Check PSU.
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC ✔*  
CMC      
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*    
CMC ✔*           ✔*

PSU0038

Message
Power supply arg1 fan is operating normally.
Arguments
arg1 = number
Detailed Description
None
Recommended Response Action
No response action is required
Category
System Health (PSU = Power Supply)
Severity
Severity 3 (Informational)
Trap/EventID
2187
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC ✔*  
CMC      
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*           ✔*

PSU0039

Message
An under current fault detected on power supply arg1 .
Arguments
arg1 = number
Detailed Description
Insufficient amount of current to keep power supply operating at a normal levels.
Recommended Response Action
1) Remove and re-install the power supply input cord. 2) Check power distribution or PSU input source for anomalies. 3) If the issue persists, contact technical support. Refer to the product documentation to choose a convenient contact method.
Category
System Health (PSU = Power Supply)
Severity
Severity 1 (Critical)
Trap/EventID
2185
LCD Message
Under current fault detected on PSU <number>. Check PSU.
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC ✔*  
CMC      
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*    
CMC ✔*           ✔*

PSU0040

Message
An output under voltage fault detected on power supply arg1 .
Arguments
arg1 = number
Detailed Description
The power supply output voltage is insufficient to keep system operating at a normal levels.
Recommended Response Action
1) Remove the power supply input cord and then remove power supply. 2) Re-install the power supply and then re-install the power supply cord. 3) If the issue persists, contact technical support. Refer to the product documentation to choose a convenient contact method.
Category
System Health (PSU = Power Supply)
Severity
Severity 1 (Critical)
Trap/EventID
2185
LCD Message
Output under voltage fault detected on PSU <number>.
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC ✔*  
CMC      
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*    
CMC ✔*           ✔*

PSU0041

Message
An output over voltage fault detected on power supply arg1 .
Arguments
arg1 = number
Detailed Description
none
Recommended Response Action
1) Remove the power supply input cord and then remove power supply. 2) Re-install the power supply and then re-install the power supply cord. 3) If the issue persists, contact technical support. Refer to the product documentation to choose a convenient contact method.
Category
System Health (PSU = Power Supply)
Severity
Severity 1 (Critical)
Trap/EventID
2185
LCD Message
Output over voltage fault on PSU <number>. Check PSU
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC ✔*  
CMC      
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*    
CMC ✔*           ✔*

PSU0042

Message
An output over current fault detected on power supply arg1 .
Arguments
arg1 = number
Detailed Description
none
Recommended Response Action
1) Remove the power supply input cord and then remove power supply. 2) Re-install the power supply and then re-install the power supply cord. 3) If the issue persists, contact technical support. Refer to the product documentation to choose a convenient contact method.
Category
System Health (PSU = Power Supply)
Severity
Severity 1 (Critical)
Trap/EventID
2185
LCD Message
Output over current fault detected on PSU <number>. Check PSU.
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC ✔*  
CMC      
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*    
CMC ✔*           ✔*

PSU0043

Message
An output under current fault detected on power supply arg1 .
Arguments
arg1 = number
Detailed Description
None
Recommended Response Action
1) Remove the power supply input cord and then remove power supply. 2) Re-install the power supply and then re-install the power supply cord. 3) If the issue persists, contact technical support. Refer to the product documentation to choose a convenient contact method.
Category
System Health (PSU = Power Supply)
Severity
Severity 1 (Critical)
Trap/EventID
2185
LCD Message
Output under current fault detected on PSU <number>. Check PSU.
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC ✔*  
CMC      
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*    
CMC ✔*           ✔*

PSU0044

Message
Cannot obtain status information from power supply arg1 .
Arguments
arg1 = number
Detailed Description
The power supply is operating but the system cannot get status information.
Recommended Response Action
If problem persist, remove and re-install power supply.
Category
System Health (PSU = Power Supply)
Severity
Severity 2 (Warning)
Trap/EventID
2186
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC ✔*  
CMC      
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*    
CMC ✔*           ✔*

PSU0045

Message
Power supply arg1 status information successfully obtained.
Arguments
arg1 = number
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health (PSU = Power Supply)
Severity
Severity 3 (Informational)
Trap/EventID
2187
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC ✔*  
CMC      
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*           ✔*

PSU0046

Message
Communication has been restored to power supply arg1 .
Arguments
arg1 = number
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health (PSU = Power Supply)
Severity
Severity 3 (Informational)
Trap/EventID
2187
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC ✔*  
CMC      
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*           ✔*

PSU0076

Message
A power supply wattage mismatch is detected; power supply arg1 is rated for arg2 watts.
Arguments
arg1 = number, arg2 = value
Detailed Description
Power supplies should be of the same input type and power rating.
Recommended Response Action
Install matched power supplies and review product documentation for proper configuration.
Category
System Health (PSU = Power Supply)
Severity
Severity 1 (Critical)
Trap/EventID
2185
LCD Message
PSU wattage mismatch; PSU <number> = <value> watts
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC ✔*  
CMC      
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*    
CMC ✔*           ✔*

PSU0077

Message
Power supply arg1 vendor type mismatch detected.
Arguments
arg1 = number
Detailed Description
Power supplies should be of the same input type and power rating.
Recommended Response Action
Install matched power supplies and review product documentation for proper configuration.
Category
System Health (PSU = Power Supply)
Severity
Severity 1 (Critical)
Trap/EventID
2185
OMSA Event ID
5354
OMSA Trap ID
5354
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC ✔*  
CMC      
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*    
CMC ✔*           ✔*

PSU0078

Message
Power supply arg1 revision mismatch detected.
Arguments
arg1 = number
Detailed Description
This power supply revision is not supported for this system.
Recommended Response Action
Review product documentation, change power supply with correct revision.
Category
System Health (PSU = Power Supply)
Severity
Severity 1 (Critical)
Trap/EventID
2185
OMSA Event ID
5354
OMSA Trap ID
5354
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC ✔*  
CMC      
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*    
CMC ✔*           ✔*

PSU0080

Message
Power supply arg1 voltage rating does not match the systems requirements.
Arguments
arg1 = number
Detailed Description
The system does not support mixed voltage power supplies.
Recommended Response Action
Review product documentation, change power supply with correct voltage rating.
Category
System Health (PSU = Power Supply)
Severity
Severity 1 (Critical)
Trap/EventID
2185
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC ✔*  
CMC      
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*    
CMC ✔*           ✔*

PSU0090

Message
Power supply arg1 wattage mismatch corrected.
Arguments
arg1 = number
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health (PSU = Power Supply)
Severity
Severity 3 (Informational)
Trap/EventID
2187
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC ✔*  
CMC      
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*           ✔*

PSU0091

Message
Power supply unit arg1 rating exceeds the system power distribution limits.
Arguments
arg1 = PSU number
Detailed Description
The rating of the power supply unit identified in the message should not exceed system power distribution limits.
Recommended Response Action
Remove the power supply unit identified in the message and review server product documentation for appropriate configuration.
Category
System Health (PSU = Power Supply)
Severity
Severity 2 (Warning)
Trap/EventID
2186
LCD Message
Power supply <number> exceeds power distribution limits. Remove PSU.
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC ✔*  
CMC      
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*    
CMC ✔*           ✔*

PSU0092

Message
Power supply unit arg1 rating is appropriate for the system power distribution limits.
Arguments
arg1 = PSU number
Detailed Description
The rating of the power supply unit identified in the message does not exceed system power distribution limits.
Recommended Response Action
No response action is required.
Category
System Health (PSU = Power Supply)
Severity
Severity 3 (Informational)
Trap/EventID
2187
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC ✔*  
CMC      
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*           ✔*

PSU0800

Message
Power Supply arg1 : Status = 0x arg2 , IOUT = 0x arg3 , VOUT= 0x arg4 , TEMP= 0x arg5 , FAN = 0x arg6 , INPUT= 0x arg7
Arguments
arg1 = PSU_name, arg2 = PSU_Status, arg3 = Output_Current, arg4 = Output_Voltage, arg5 = Temp, arg6 = Fan, arg7 = Input
Detailed Description
Lists the complete status of the power supply unit.
Recommended Response Action
No response action is required.
Category
System Health (PSU = Power Supply)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

PSU0801

Message
Power Supply arg1 : CRC error detected
Arguments
arg1 = PSU_Name
Detailed Description
The Power Supply had a CRC error detected
Recommended Response Action
Aquire the power supply firmware image and update the power supply indicated in the message.
Category
System Health (PSU = Power Supply)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

PSU0802

Message
The power supply redundancy policy on the system has been set.
Detailed Description
The power supply redundancy policy on the system has been set.
Recommended Response Action
No response action is required.
Category
System Health (PSU = Power Supply)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

PSU0803

Message
Insufficient power in chassis to power on server.
Detailed Description
Insufficient power in chassis to power on server.
Recommended Response Action
Utilize the Chassis Management Controller web interface to check available power and server power requirements. If sufficient power is available, retry the operation.
Category
System Health (PSU = Power Supply)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

PSU0900

Message
Power unit arg1 is off.
Arguments
arg1 = number
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health (PSU = Power Supply)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

PSU0901

Message
Power unit arg1 is on.
Arguments
arg1 = number
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health (PSU = Power Supply)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

PSU0902

Message
Power unit arg1 was power cycled.
Arguments
arg1 = number
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health (PSU = Power Supply)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

PSU0904

Message
Could not power down 240VA on power unit arg1 .
Arguments
arg1 = number
Detailed Description
In order to meet service requirements the supply must be shut down.
Recommended Response Action
Remove input power at the power supply.
Category
System Health (PSU = Power Supply)
Severity
Severity 1 (Critical)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

PSU0906

Message
An interlock power down error detected on power unit arg1 .
Arguments
arg1 = number
Detailed Description
In order to meet service requirements the supply must be shut down.
Recommended Response Action
Remove input power at the power supply.
Category
System Health (PSU = Power Supply)
Severity
Severity 1 (Critical)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

PSU0907

Message
An interlock power down error was corrected for power unit arg1 .
Arguments
arg1 = number
Detailed Description
None
Recommended Response Action
Remove input power at the power supply.
Category
System Health (PSU = Power Supply)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

PSU0908

Message
Power lost on power unit arg1 .
Arguments
arg1 = number
Detailed Description
The power supply is installed correctly but an input source is not connected or is not functional.
Recommended Response Action
Verify the input source is attached to the power supply. Verify the input power is within the operating requirements for the power supply.
Category
System Health (PSU = Power Supply)
Severity
Severity 1 (Critical)
OMSA Event ID
5354
OMSA Trap ID
5354
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

PSU0909

Message
Power restored on power unit arg1 .
Arguments
arg1 = number
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health (PSU = Power Supply)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

PSU0910

Message
Soft power control failure detected on power unit arg1 .
Arguments
arg1 = number
Detailed Description
The system did not respond correctly to a power down request.
Recommended Response Action
Disconnect Input Power
Category
System Health (PSU = Power Supply)
Severity
Severity 1 (Critical)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

PSU0911

Message
Soft power control restored on power unit arg1 .
Arguments
arg1 = number
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health (PSU = Power Supply)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

PSU0912

Message
A failure detected on power unit arg1 .
Arguments
arg1 = number
Detailed Description
Status from the power supply indicates a power supply exception occurred. The power supply will try to operate in a degraded state. System Performance and power redundancy may be degraded or lost.
Recommended Response Action
Check input power. Re-install the power supply. If problem persists contact support.
Category
System Health (PSU = Power Supply)
Severity
Severity 1 (Critical)
OMSA Event ID
5354
OMSA Trap ID
5354
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

PSU0913

Message
Power unit arg1 is operating normally.
Arguments
arg1 = number
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health (PSU = Power Supply)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

PSU0914

Message
A predictive failure detected on power unit arg1 .
Arguments
arg1 = number
Detailed Description
Status from the power supply indicates a power supply exception occurred. The power supply will try to operate. System Performance and power redundancy may be degraded or lost.
Recommended Response Action
Remove input power and re-install supply at the next service window.
Category
System Health (PSU = Power Supply)
Severity
Severity 2 (Warning)
OMSA Event ID
5353
OMSA Trap ID
5353
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

PSU100

Message
Power supply arg1 is offline.
Arguments
arg1 = power supply unit
Detailed Description
The power supply unit identified in the message is offline, because of the one of the following reasons: 1) The power supply unit is not correctly seated. 2) The power cable may not be connected properly or diconnected. 3) The power supply unit has failed. 4) There is an input power failure.
Recommended Response Action
Do one of the following to resolve the issue: 1) reseat the power supply unit. 2) Reconnect the power cable to the power supply unit. 3) Install a new power supply unit 4) Restore the input power supply.
Category
System Health (PSU = Power Supply)
Severity
Severity 2 (Warning)
OMSA Event ID
5303
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC          
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC     ✔*        
CMC              

PSU1000

Message
Power supply cable has been removed from arg1 .
Arguments
arg1 = PSU Sensor Name
Detailed Description
The power supply unit is not receiving input AC power. The power cable may not be connected properly or removed. This can happen if there is an AC failure or problems with the power strip attached to the enclosure power supply.
Recommended Response Action
Reconnect the power cable to the power supply unit if it was disconnected. Restore the input AC power supply. Make sure the power supply is restored to the enclosure from the mains.
Category
Storage (PSU = Power Supply)
Severity
Severity 2 (Warning)
Trap/EventID
4234
OMSA Event ID
2312;2313
OMSA Trap ID
100300
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*         ✔*

PSU1001

Message
arg1 has failed.
Arguments
arg1 = PSU Sensor Name
Detailed Description
The enclosure detected that a power supply unit has failed.
Recommended Response Action
Check for other messages related to the state of the power supply unit/enclosure. These may help determine the cause of this event. Contact technical support if the issue still persists.
Category
Storage (PSU = Power Supply)
Severity
Severity 1 (Critical)
Trap/EventID
4233
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*         ✔*

PSU1002

Message
arg1 was removed
Arguments
arg1 = PSU Sensor Name
Detailed Description
The enclosure detected that a power supply unit was removed and is no longer functioning in optimal condition.
Recommended Response Action
Re-insert the power supply unit into the enclosure. Re-connect the AC power cable and switch on the power supply unit. Contact technical support if the issue persists.
Category
Storage (PSU = Power Supply)
Severity
Severity 1 (Critical)
Trap/EventID
4233
OMSA Event ID
2324
OMSA Trap ID
100400
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*         ✔*

PSU1003

Message
arg1 is switched OFF.
Arguments
arg1 = PSU Sensor Name
Detailed Description
The power supply is not providing any power. This may be because the power supply switch is in the off position or the power supply has failed.
Recommended Response Action
Check whether the power switch on the power supply unit is turned off or on. If it is turned off, turn it on. If the problem is not corrected, verify that the power cord is attached and functional. See the storage hardware documentation for more information.
Category
Storage (PSU = Power Supply)
Severity
Severity 2 (Warning)
Trap/EventID
4234
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*         ✔*

PSU1004

Message
Power supply cable has been inserted into arg1 .
Arguments
arg1 = PSU Sensor Name
Detailed Description
The enclosure detected that AC power supply was restored to the power supply unit.
Recommended Response Action
No response action is required.
Category
Storage (PSU = Power Supply)
Severity
Severity 3 (Informational)
Trap/EventID
4235
OMSA Event ID
2325
OMSA Trap ID
100100
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*         ✔*

PSU1005

Message
arg1 is switched on.
Arguments
arg1 = PSU sensor name
Detailed Description
The enclosure detected that a power supply unit was switched on.
Recommended Response Action
No response action is required.
Category
Storage (PSU = Power Supply)
Severity
Severity 3 (Informational)
Trap/EventID
4235
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*         ✔*

PSU1006

Message
arg1 was inserted.
Arguments
arg1 = PSU sensor name
Detailed Description
The enclosure detected that a power supply unit was inserted.
Recommended Response Action
No response action is required.
Category
Storage (PSU = Power Supply)
Severity
Severity 3 (Informational)
Trap/EventID
4235
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*         ✔*

PSU1007

Message
arg1 has failed.
Arguments
arg1 = PSU Sensor Name
Detailed Description
A device has been failed and the system is no longer functioning in optimal condition.
Recommended Response Action
Replace the device.
Category
Storage (PSU = Power Supply)
Severity
Severity 1 (Critical)
Trap/EventID
4233
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*         ✔*

PSU101

Message
Power supply arg1 is not present.
Arguments
arg1 = power supply unit
Detailed Description
The power supply unit identified in the message is not present, because of the one of the following reasons: 1) The power supply unit is not correctly seated. 2) The power cable may not be connected properly or diconnected. 3) The power supply unit has failed. 4) There is an input power failure.
Recommended Response Action
Do one of the following to resolve the issue: 1) reseat the power supply unit. 2) Reconnect the power cable to the power supply unit. 3) Install a new power supply unit 4) Restore the input power supply.
Category
System Health (PSU = Power Supply)
Severity
Severity 1 (Critical)
OMSA Event ID
5352
OMSA Trap ID
5352
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC     ✔*    
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC     ✔*        
CMC              

PSU1010

Message
The DC power supply is switched off.
Detailed Description
The power supply unit is switched off. Either you have switched off the power supply unit or it is defective.
Recommended Response Action
Check to see whether the power switch is turned off or on. If it is turned off, turn it on. If the problem is not corrected, verify that the power cord is attached and functional. If the problem continues or if the power switch is already turned on, then replace the power supply unit.
Category
Storage (PSU = Power Supply)
Severity
Severity 1 (Critical)
Trap/EventID
4233
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*         ✔*

PSU102

Message
Power suppy arg1 status is unknown.
Arguments
arg1 = power supply unit
Detailed Description
The status of the power supply unit identified in the message is unknown, because of one of the following reasons: 1) The power supply unit is not correctly seated. 2) The power cable may not be connected properly or diconnected. 3) The power supply unit has failed. 4) There is an input power failure.
Recommended Response Action
Do one of the following to resolve the issue: 1) reseat the power supply unit. 2) Reconnect the power cable to the power supply unit. 3) Install a new power supply unit 4) Restore the input power supply.
Category
System Health (PSU = Power Supply)
Severity
Severity 2 (Warning)
OMSA Event ID
5351
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC          
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC     ✔*        
CMC              

PSU1050

Message
arg1 is switched ON.
Arguments
arg1 = power supply name
Detailed Description
The power supply identified in the message is switched ON.
Recommended Response Action
No response action is required.
Category
Storage (PSU = Power Supply)
Severity
Severity 3 (Informational)
OMSA Event ID
2323
OMSA Trap ID
100100
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC        
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC            
CMC              

PSU500

Message
Unable to get the current server power status.
Detailed Description
Racadm tool cannot obtain the power status possible reason is that the IPMI call failed.
Recommended Response Action
No response action is required.
Category
System Health (PSU = Power Supply)
Severity
Severity 1 (Critical)
No alerts are applicable for this message

PSU501

Message
Server is already powered ON.
Detailed Description
The server was already up, when the user gave a power on request.
Recommended Response Action
No response action is required.
Category
System Health (PSU = Power Supply)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

PSU502

Message
Server is already powered OFF.
Detailed Description
The server was already down, when the user gave a power off request.
Recommended Response Action
No response action is required.
Category
System Health (PSU = Power Supply)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

PSU503

Message
Server power status: arg1
Arguments
arg1 = Status
Detailed Description
Success message.
Recommended Response Action
No response action is required.
Category
System Health (PSU = Power Supply)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

PSU504

Message
Server power operation successful
Detailed Description
Success message.
Recommended Response Action
No response action is required.
Category
System Health (PSU = Power Supply)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

PSU8501

Message
Unable to retrieve PSU arg1 input voltage information.
Arguments
arg1 = slot number
Detailed Description
Unable to retrieve input voltage information for the PSU specified in the message.
Recommended Response Action
Remove the PSU from the chassis, wait for two minutes, and reinsert it. If the issue persists, contact your service provider.
Category
Audit (PSU = Power Supply)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

PSU8502

Message
The PSU in slot arg1 detected 110 VAC input voltage and does not match chassis configuration.
Arguments
arg1 = slot number
Detailed Description
The input voltage of the PSU specified in the message does not match the input voltage of the PSUs already present in the chassis.
Recommended Response Action
Do the following: 1) Check the power configuration "Allow 110 VAC Operation" setting and make sure it is enabled. 2) Check if the input voltage of all the PSUs are the same. 3) If the input voltage of the PSU specified in the message is not the same, then remove the unmatched PSU.
Category
Audit (PSU = Power Supply)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

PSU8503

Message
The PSU in slot arg1 detected 220 VAC input voltage and does not match chassis configuration.
Arguments
arg1 = slot number
Detailed Description
The input voltage of the PSU specified in the message does not match the input voltage of the PSUs already present in the chassis.
Recommended Response Action
Do the following: 1) Check if the input voltage of all the PSUs are the same. 2) If the input voltage of the PSU specified in the message is not the same, then remove the unmatched PSU.
Category
Audit (PSU = Power Supply)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

PSU8504

Message
The Allow 110 VAC Operation overload risk is not acknowledged.
Detailed Description
Selecting the Allow 110 VAC Operation involves potential risk that an overload can occur. The overload risk was not acknowledged in the CMC Web interface when the selection was made.
Recommended Response Action
Select the Allow 110 VAC Operation and accept the subsequent dialog that acknowledges the overload risk.
Category
Audit (PSU = Power Supply)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

PSU8505

Message
Unable to set the chassis redundancy policy to AC Redundancy.
Detailed Description
Unable to set the chassis redundancy policy to AC Redundancy.
Recommended Response Action
Retry the operation using the CMC command line interface or CMC Web interface. To set the chassis redundancy policy using the command line, enter "racadm config -g cfgChassisPower -o cfgChassisRedundancyPolicy 1". To configure the chassis redundancy policy using the Web interface, click Chassis Overview > Power > Configuration. From the Redundancy drop-down menu, select AC Redundancy.
Category
Audit (PSU = Power Supply)
Severity
Severity 1 (Critical)
Trap/EventID
8329
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC   ✔* ✔* ✔* ✔*  
CMC   ✔* ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*   ✔*        
CMC ✔*           ✔*

PSU8506

Message
Unable to change power cap because Server Based Power Management Mode is enabled.
Detailed Description
When the Server Power Management mode is enabled the Power cap cannot be set.
Recommended Response Action
To enable the ability to set the power cap, switch to external Power Management and disable the Server Based Management Mode in the CMC Web interface.
Category
Audit (PSU = Power Supply)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC       ✔*    
CMC       ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

PSU8507

Message
Insufficient power available because PSU in the slot arg1 is not present..
Arguments
arg1 = slot number
Detailed Description
The PSU identified in the message has been disengaged or removed. Insufficient power is available.
Recommended Response Action
Insert a PSU in the slot identified in the message.
Category
Audit (PSU = Power Supply)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

PSU8508

Message
arg1 , PSU arg2 firmware update is in progress.
Arguments
arg1 = error string, arg2 = slot number
Detailed Description
Unable to set the Power configuration because the PSU firmware update is in progress.
Recommended Response Action
Retry the operation after the PSU firmware update is completed.
Category
Audit (PSU = Power Supply)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

PSU8510

Message
PSU in slot arg1 FW updated successfully to version arg2
Arguments
arg1 = slot number, arg2 = version number
Detailed Description
The firmware for the PSU identified in the message is successfully updated to the version displayed in the message
Recommended Response Action
No response action is required.
Category
Audit (PSU = Power Supply)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

PSU8511

Message
Successfully updated the firmware for the PSU in slot arg1 .
Arguments
arg1 = slot number
Detailed Description
The firmware for the PSU identified in the message was successfully updated.
Recommended Response Action
No response action is required.
Category
Audit (PSU = Power Supply)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC       ✔*    
CMC       ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

PSU8512

Message
Unable to update the firmware for the PSU in slot arg1 . Error=0x arg2 ( arg3 )
Arguments
arg1 = slot number, arg2 = error number, arg3 = error string
Detailed Description
The firmware update operation for the PSU identified in the message did not complete, because of internal communication errors.
Recommended Response Action
Retry the firmware update operation. If the issue persists, contact your service provider.
Category
Audit (PSU = Power Supply)
Severity
Severity 2 (Warning)
Trap/EventID
8330
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC   ✔* ✔* ✔* ✔*  
CMC   ✔* ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*   ✔*        
CMC ✔*           ✔*

PSU8513

Message
Unable to complete the PSU slot arg1 firmware update. Error=0x arg2 .
Arguments
arg1 = number, arg2 = error number
Detailed Description
Unable to update the PSU firmware due to PMBus communication errors.
Recommended Response Action
Retry the firmware update operation. If the problem persists, contact your service provider.
Category
Audit (PSU = Power Supply)
Severity
Severity 2 (Warning)
Trap/EventID
8330
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC   ✔* ✔* ✔* ✔*  
CMC   ✔* ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*   ✔*        
CMC ✔*           ✔*

PSU8515

Message
Unable to set the Enable Dynamic Power Supply Engagement attribute.
Detailed Description
Unable to set the Enable Dynamic Power Supply Engagement attribute.
Recommended Response Action
Do the following: 1) Retry the operation. 2) If the issue persists, review the tracelog for more details. To retrieve the tracelog, in the CMC Web interface, go to Troubleshooting > Diagnostics page and enter the "gettracelog" command, or use RACADM "gettracelog" command. If the issue continues to persist, contact your service provider and provide the tracelog.
Category
Audit (PSU = Power Supply)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC       ✔*    
CMC       ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

PSU8516

Message
Unable to set redundancy policy because PSU enumeration is in progress.
Detailed Description
Unable to set redundancy policy because PSU enumeration is in progress. The policy can be set after PSU enumeration is complete.
Recommended Response Action
Retry the operation after the PSU enumeration is complete.
Category
Audit (PSU = Power Supply)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC       ✔*    
CMC       ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

PSU8517

Message
PSU redundancy policy changed.
Detailed Description
The operation to change the PSU redundancy policy is complete.
Recommended Response Action
No response action is required.
Category
Audit (PSU = Power Supply)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC       ✔*    
CMC       ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

PSU8518

Message
Unable to access the PSU arg1 FRU data.
Arguments
arg1 = slot number
Detailed Description
The operation to read the FRU data from the PSU identified in the message did not complete successfully due to internal communication errors.
Recommended Response Action
Retry the operation. If the condition persists, contact your service provider.
Category
Audit (PSU = Power Supply)
Severity
Severity 1 (Critical)
Trap/EventID
8329
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC   ✔* ✔* ✔* ✔*  
CMC   ✔* ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*   ✔*        
CMC ✔*           ✔*

PSU8519

Message
Enhanced Dynamic Power Supply Engagement (DPSE) is not supported by the current power supply configuration and is suspended.
Detailed Description
The Dynamic Power Supply Engagement (DPSE) feature is suspended due to the configuration or the type of PSU present. The feature is enabled, but suspended until a supported PSU configuration is in place.
Recommended Response Action
Dynamic Power Supply Engagement (DPSE) is not supported by the current power supply configuration. Verify the PSUs are supported. Replace the unsupported PSUs.
Category
Audit (PSU = Power Supply)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC       ✔*    
CMC       ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

PSU8520

Message
Enhanced Dynamic Power Supply Engagement (DPSE) is fully supported.
Detailed Description
The Dynamic Power Supply Engagement feature is supported and fully operational.
Recommended Response Action
No response action is required.
Category
Audit (PSU = Power Supply)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

PSU8521

Message
PSU arg1 exceeded upper temperature threshold and has been turned off.
Arguments
arg1 = slotnum
Detailed Description
The power supply unit (PSU) identified in the message was turned off because the termperature exceeded the high temperature threshold in the unit.
Recommended Response Action
Remove and reinsert the PSU or remove AC power and reapply power to the PSU to get it functional again.
Category
Audit (PSU = Power Supply)
Severity
Severity 1 (Critical)
Trap/EventID
8329
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC   ✔* ✔* ✔* ✔*  
CMC   ✔* ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*   ✔*        
CMC ✔*           ✔*

Rate this content

Accurate
Useful
Easy to understand
Was this article helpful?
0/3000 characters
  Please provide ratings (1-5 stars).
  Please provide ratings (1-5 stars).
  Please provide ratings (1-5 stars).
  Please select whether the article was helpful or not.
  Comments cannot contain these special characters: <>()\