VDR Event Messages

VDR1

Message
arg1 failed.
Arguments
arg1 = VD Name
Detailed Description
A storage component such as a physical disk or an enclosure has failed. The failed component may have been identified by the controller while performing a task such as a rescan or a check consistency.
Recommended Response Action
Replace the failed component. You can identify which component has failed by locating the component that has a red "X" for its status. Perform a rescan after replacing the failed component.
Category
Storage (VDR = Virtual Disk)
Severity
Severity 1 (Critical)
Trap/EventID
4353
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*        

VDR10

Message
Formatting the arg1 has started.
Arguments
arg1 = VD Name
Detailed Description
This alert is provided for informational purposes.
Recommended Response Action
No response action is required.
Category
Storage (VDR = Virtual Disk)
Severity
Severity 3 (Informational)
Trap/EventID
4355
OMSA Event ID
2059
OMSA Trap ID
120100
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*        

VDR100

Message
arg1 is unavailable because of incompatibilities with the current controller.
Arguments
arg1 = virtual disk
Detailed Description
The virtual disk identified in message cannot be used because of missing features on the current controller. The features may be missing because they are not available in the firmware version on the controller or the necessary licenses are not installed.
Recommended Response Action
Update the controller firmware and license to match the peer controller.
Category
Storage (VDR = Virtual Disk)
Severity
Severity 2 (Warning)
Trap/EventID
4354
OMSA Event ID
2369
OMSA Trap ID
120100
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*        

VDR101

Message
Hot Spare Protection policy deviation with severity set at Informational level occured for arg1 .
Arguments
arg1 = virtual disk names
Detailed Description
The number of hot spares available for the virtual disks identified in the message are not compliant with Hot Spare Protection policy, whose severity is set at Informational level.
Recommended Response Action
Make appropriate assignments of hotspares to meet the policy.
Category
Storage (VDR = Virtual Disk)
Severity
Severity 3 (Informational)
OMSA Event ID
2383
OMSA Trap ID
120100
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC        
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC            
CMC              

VDR101

Message
Virtual Adapter mapping reported for arg1 . Virtual Adapter 1 is now arg2 . Virtual Adapter 2 is now arg3 . Virtual Adapter 3 is now arg4 . Virtual Adapter 4 is now arg5
Arguments
arg1 = Virtual Disk Name, arg2 = Access Policy 1, arg3 = Access Policy 2, arg4 = Access Policy 3, arg5 = Access Policy 4
Detailed Description
Indicates the Virtual Disk to Virtual Adapter Mapping for audit purposes.
Recommended Response Action
No response action is required.
Category
Storage (VDR = Virtual Disk)
Severity
Severity 3 (Informational)
Trap/EventID
4355
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*        

VDR102

Message
Hot Spare Protection policy deviation with severity set at Warning level occured for arg1 .
Arguments
arg1 = virtual disk names
Detailed Description
The number of hot spares available for the virtual disks identified in the message are not compliant with Hot Spare Protection policy, whose severity is set at Warning level.
Recommended Response Action
Make appropriate assignments of hotspares to meet the policy.
Category
Storage (VDR = Virtual Disk)
Severity
Severity 2 (Warning)
OMSA Event ID
2384
OMSA Trap ID
120300
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC        
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC            
CMC              

VDR103

Message
Hot Spare Protection policy deviation with severity set at Critical level occured for arg1 .
Arguments
arg1 = virtual disk names
Detailed Description
The number of hot spares available for the virtual disks identified in the message are not compliant with Hot Spare Protection policy, whose severity is set at Critical level.
Recommended Response Action
Make appropriate assignments of hotspares to meet the policy.
Category
Storage (VDR = Virtual Disk)
Severity
Severity 1 (Critical)
OMSA Event ID
2385
OMSA Trap ID
120400
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC        
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC            
CMC              

VDR104

Message
Successfully secured arg1 .
Arguments
arg1 = virtual disk name
Detailed Description
The secure virtual disk operation was successful on the security capable virtual disk identified in the message. A security capable virtual disk is created using only Self-Encrypting Drives (SED).
Recommended Response Action
No response action is required.
Category
Storage (VDR = Virtual Disk)
Severity
Severity 3 (Informational)
OMSA Event ID
2393
OMSA Trap ID
120100
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC        
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC            
CMC              

VDR105

Message
The arg1 on power save mode drives is available.
Arguments
arg1 = virtual disk name
Detailed Description
Virtual Disk creation using power save mode drives successfully completed and the Virtual Disk identified in the message is ready for use.
Recommended Response Action
No response action is required.
Category
Storage (VDR = Virtual Disk)
Severity
Severity 3 (Informational)
OMSA Event ID
2403
OMSA Trap ID
120100
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC        
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC            
CMC              

VDR106

Message
arg1 on spun down power save mode drives is not available.
Arguments
arg1 = virtual disk name
Detailed Description
This alert is generated after successfully configuring a virtual disk on at least one spundown drive. The virtual disk creation is not yet complete on the remaining spundown drives because the drives are still spinning up.
Recommended Response Action
No response action is required.
Category
Storage (VDR = Virtual Disk)
Severity
Severity 3 (Informational)
OMSA Event ID
2404
OMSA Trap ID
120100
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC        
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC            
CMC              

VDR107

Message
Successfully resized Controller Enhanced cache ( arg1 ).
Arguments
arg1 = virtual disk name
Detailed Description
The Controller Enhanced cache identified in the message was successfully resized.
Recommended Response Action
No response action is required.
Category
Storage (VDR = Virtual Disk)
Severity
Severity 3 (Informational)
OMSA Event ID
2412
OMSA Trap ID
120100
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC        
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC            
CMC              

VDR108

Message
Successfully created Controller Enhanced cache ( arg1 ).
Arguments
arg1 = virtual disk name
Detailed Description
The Controller Enhanced cache identified in the message was successfully created.
Recommended Response Action
No response action is required.
Category
Storage (VDR = Virtual Disk)
Severity
Severity 3 (Informational)
OMSA Event ID
2413
OMSA Trap ID
120100
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC        
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC            
CMC              

VDR109

Message
Successfully deleted Controller Enhanced cache ( arg1 ).
Arguments
arg1 = virtual disk name
Detailed Description
The Controller Enhanced cache identified in the message was successfully deleted.
Recommended Response Action
No response action is required.
Category
Storage (VDR = Virtual Disk)
Severity
Severity 3 (Informational)
OMSA Event ID
2414
OMSA Trap ID
120100
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC        
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC            
CMC              

VDR11

Message
arg1 has started initializing.
Arguments
arg1 = virtual disk
Detailed Description
This message is generated after initialization of a virtual disk starts.
Recommended Response Action
No response action is required.
Category
Storage (VDR = Virtual Disk)
Severity
Severity 3 (Informational)
Trap/EventID
4355
OMSA Event ID
2061
OMSA Trap ID
120100
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*        

VDR110

Message
Unrecoverable storage medium error detected on arg1 .
Arguments
arg1 = virtual disk name
Detailed Description
This alert is generated when an unrecoverable storage medium error is detected on the virtual disk. This error can be a prelude to the physical disk disk becoming non-functional.
Recommended Response Action
Make sure a hot spare to the Virtual Disk identified in the message is available and back up the data on the virtual disk.
Category
Storage (VDR = Virtual Disk)
Severity
Severity 1 (Critical)
OMSA Event ID
2417
OMSA Trap ID
120400
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC        
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC            
CMC              

VDR111

Message
Corrected disk storage medium error on arg1 .
Arguments
arg1 = virtual disk name
Detailed Description
The controller corrected a disk storage medium error on one of the participating physical disks of the virtual disk identified in the message.
Recommended Response Action
No response action is required.
Category
Storage (VDR = Virtual Disk)
Severity
Severity 3 (Informational)
OMSA Event ID
2418
OMSA Trap ID
120100
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC        
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC            
CMC              

VDR112

Message
Deleted the arg1 .
Arguments
arg1 = virtual disk
Detailed Description
The controller removed a virtual disk because of a delete virtual disk operation or a reset configuration operation.
Recommended Response Action
No response action is required.
Category
Storage (VDR = Virtual Disk)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC        
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC            
CMC              

VDR12

Message
arg1 reconfiguration has started.
Arguments
arg1 = virtual disk
Detailed Description
This message is generated after reconfiguration of a virtual disk starts.
Recommended Response Action
No response action is required.
Category
Storage (VDR = Virtual Disk)
Severity
Severity 3 (Informational)
Trap/EventID
4355
OMSA Event ID
2063
OMSA Trap ID
120100
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*        

VDR13

Message
arg1 rebuild has started.
Arguments
arg1 = VD Name
Detailed Description
This alert is provided for informational purposes.
Recommended Response Action
No response action is required.
Category
Storage (VDR = Virtual Disk)
Severity
Severity 3 (Informational)
Trap/EventID
4355
OMSA Event ID
2064
OMSA Trap ID
120100
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*         ✔*

VDR14

Message
The consistency check on arg1 was cancelled.
Arguments
arg1 = virtual disk
Detailed Description
A user cancelled the consistency check operation for a virtual disk.
Recommended Response Action
No response action is required.
Category
Storage (VDR = Virtual Disk)
Severity
Severity 3 (Informational)
Trap/EventID
4355
OMSA Event ID
2067
OMSA Trap ID
120100
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*         ✔*

VDR15

Message
Initialization of arg1 was cancelled.
Arguments
arg1 = virtual disk
Detailed Description
The initialization operation could not be completed. This may be due to a user action or a physical disk failure.
Recommended Response Action
If a physical disk failed, then replace the physical disk. Restart the virtual disk initialization.
Category
Storage (VDR = Virtual Disk)
Severity
Severity 3 (Informational)
Trap/EventID
4355
OMSA Event ID
2070
OMSA Trap ID
120100
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*         ✔*

VDR16

Message
Consistency check of arg1 failed.
Arguments
arg1 = virtual disk
Detailed Description
A physical disk included in the virtual disk failed or there is an error in the parity information. A failed physical disk causes errors in parity information.
Recommended Response Action
Check that all the physical disks of the virtual disk are in a healthy condition. Replace any disks that are not healthy and restart the operation. If this is not the problem, delete the virtual disk and restore the data to the disk from a backup copy.
Category
Storage (VDR = Virtual Disk)
Severity
Severity 1 (Critical)
Trap/EventID
4353
OMSA Event ID
2076
OMSA Trap ID
120400
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*         ✔*

VDR17

Message
arg1 format failed.
Arguments
arg1 = VD Name
Detailed Description
A physical disk included in the virtual disk failed.
Recommended Response Action
Replace the failed physical disk. Identify the failed physical disk by locating the disk that has a red "X" for its status. Rebuild the physical disk. When finished, restart the virtual disk format operation.
Category
Storage (VDR = Virtual Disk)
Severity
Severity 1 (Critical)
Trap/EventID
4353
OMSA Event ID
2077
OMSA Trap ID
120400
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*         ✔*

VDR18

Message
Initialization of arg1 has failed.
Arguments
arg1 = virtual disk
Detailed Description
A physical disk included in the virtual disk has failed or was removed.
Recommended Response Action
If a physical disk has failed, replace the physical disk. Restart the virtual disk initialization.
Category
Storage (VDR = Virtual Disk)
Severity
Severity 1 (Critical)
Trap/EventID
4353
OMSA Event ID
2079
OMSA Trap ID
120400
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*         ✔*

VDR19

Message
Reconfiguration of arg1 has failed.
Arguments
arg1 = virtual disk
Detailed Description
The reconfiguration operation was not completed. This may be due to a user action or a physical disk failure.
Recommended Response Action
Recreate the virtual disk and restore data from a backup copy.
Category
Storage (VDR = Virtual Disk)
Severity
Severity 1 (Critical)
Trap/EventID
4353
OMSA Event ID
2081
OMSA Trap ID
120400
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*         ✔*

VDR2

Message
arg1 returned to optimal state.
Arguments
arg1 = virtual disk
Detailed Description
The virtual disk has returned to a healthy state and is working properly.
Recommended Response Action
No response action is required.
Category
Storage (VDR = Virtual Disk)
Severity
Severity 3 (Informational)
Trap/EventID
4355
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*         ✔*

VDR20

Message
arg1 rebuild failed.
Arguments
arg1 = VD Name
Detailed Description
A physical disk included in the virtual disk has failed or is corrupt. You may also have cancelled the rebuild.
Recommended Response Action
Replace the failed or corrupt disk. You can identify a disk that has failed by locating the disk that has a red "X" for its status. Restart the virtual disk rebuild.
Category
Storage (VDR = Virtual Disk)
Severity
Severity 1 (Critical)
Trap/EventID
4353
OMSA Event ID
2082
OMSA Trap ID
120400
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC            
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*         ✔*

VDR21

Message
Consistency check for arg1 has completed.
Arguments
arg1 = virtual disk
Detailed Description
This message is generated after a consistency check completes on a virtual disk.
Recommended Response Action
No response action is required.
Category
Storage (VDR = Virtual Disk)
Severity
Severity 3 (Informational)
Trap/EventID
4355
OMSA Event ID
2085
OMSA Trap ID
120100
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*         ✔*

VDR22

Message
Formatting the arg1 is completed.
Arguments
arg1 = VD Name
Detailed Description
This alert is provided for informational purposes.
Recommended Response Action
No response action is required.
Category
Storage (VDR = Virtual Disk)
Severity
Severity 3 (Informational)
Trap/EventID
4355
OMSA Event ID
2086
OMSA Trap ID
120100
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*         ✔*

VDR23

Message
Initialization of arg1 has completed.
Arguments
arg1 = virtual disk
Detailed Description
This message is generated after initialization completes on a virtual disk.
Recommended Response Action
No response action is required.
Category
Storage (VDR = Virtual Disk)
Severity
Severity 3 (Informational)
Trap/EventID
4355
OMSA Event ID
2088
OMSA Trap ID
120100
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*         ✔*

VDR24

Message
Reconfiguration of arg1 has completed.
Arguments
arg1 = virtual disk
Detailed Description
The re-configuration operation on the virtual disk completed.
Recommended Response Action
No response action is required.
Category
Storage (VDR = Virtual Disk)
Severity
Severity 3 (Informational)
Trap/EventID
4355
OMSA Event ID
2090
OMSA Trap ID
120100
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*         ✔*

VDR25

Message
arg1 rebuild is completed.
Arguments
arg1 = VD Name
Detailed Description
This alert is provided for informational purposes.
Recommended Response Action
No response action is required.
Category
Storage (VDR = Virtual Disk)
Severity
Severity 3 (Informational)
Trap/EventID
4355
OMSA Event ID
2091
OMSA Trap ID
120100
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*         ✔*

VDR26

Message
The check consistency on a arg1 has been paused (suspended).
Arguments
arg1 = VD Name
Detailed Description
You paused the Check Consistency operation on a virtual disk.
Recommended Response Action
To resume the Check Consistency operation, right-click the virtual disk in the Storage Management tree view and select Resume Check Consistency.
Category
Storage (VDR = Virtual Disk)
Severity
Severity 3 (Informational)
Trap/EventID
4355
OMSA Event ID
2114
OMSA Trap ID
120100
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*         ✔*

VDR27

Message
The consistency check on a arg1 has been resumed.
Arguments
arg1 = VD Name
Detailed Description
The check consistency on a virtual disk has resumed processing after a pause.
Recommended Response Action
This alert is provided for informational purposes.
Category
Storage (VDR = Virtual Disk)
Severity
Severity 3 (Informational)
Trap/EventID
4355
OMSA Event ID
2115
OMSA Trap ID
120100
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*         ✔*

VDR28

Message
A virtual disk and its mirror have been split.
Detailed Description
A user has caused a mirrored virtual disk to be split. When a virtual disk is mirrored, its data is copied to another virtual disk to maintain redundancy. After being split, both virtual disks retain a copy of the data. Because the mirror is no longer intact, updates to the data are no longer copied to the mirror.
Recommended Response Action
This alert is provided for informational purposes.
Category
Storage (VDR = Virtual Disk)
Severity
Severity 3 (Informational)
Trap/EventID
4355
OMSA Event ID
2116
OMSA Trap ID
120100
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*         ✔*

VDR29

Message
A mirrored virtual disk has been un-mirrored.
Detailed Description
A mirrored virtual disk is un-mirrored. When a virtual disk is mirrored, its data is copied to another virtual disk to maintain redundancy. After being un-mirrored, the disk formerly used as the mirror returns to being a physical disk and becomes available for inclusion in another virtual disk.
Recommended Response Action
This alert is provided for informational purposes.
Category
Storage (VDR = Virtual Disk)
Severity
Severity 3 (Informational)
Trap/EventID
4355
OMSA Event ID
2117
OMSA Trap ID
120100
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*         ✔*

VDR3

Message
Redundancy normal on arg1 .
Arguments
arg1 = VD Name
Detailed Description
Data redundancy has been restored to a virtual disk that previously suffered a loss of redundancy.
Recommended Response Action
This alert is provided for informational purposes.
Category
Storage (VDR = Virtual Disk)
Severity
Severity 3 (Informational)
Trap/EventID
4355
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*         ✔*

VDR30

Message
arg1 write policy has changed.
Arguments
arg1 = virtual disk
Detailed Description
A user changed the write policy for a virtual disk.
Recommended Response Action
This alert is provided for informational purposes.
Category
Storage (VDR = Virtual Disk)
Severity
Severity 3 (Informational)
Trap/EventID
4355
OMSA Event ID
2118
OMSA Trap ID
120100
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*         ✔*

VDR31

Message
Controller cache is preserved for missing or offline arg1 .
Arguments
arg1 = VD Name
Detailed Description
The controller is getting disconnected from its virtual disk, while Input Output (IO) is in-progress.
Recommended Response Action
Try importing foreign disks, if any. Check if the enclosure containing the Virtual Disk is disconnected from the controller. Insert any disks that are reported missing or failed. If the enclosure or disks were removed intentionally, the preserved cache can be discarded. See storage hardware documentation for more information on performing these steps.
Category
Storage (VDR = Virtual Disk)
Severity
Severity 2 (Warning)
Trap/EventID
4354
OMSA Event ID
2125
OMSA Trap ID
120300
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*         ✔*

VDR32

Message
Background initialization has started for arg1 .
Arguments
arg1 = virtual disk
Detailed Description
Background initialization of a virtual disk has started. This is an automated process that writes the parity or mirror data on newly created virtual disks.
Recommended Response Action
No response action is required.
Category
Storage (VDR = Virtual Disk)
Severity
Severity 3 (Informational)
Trap/EventID
4355
OMSA Event ID
2127
OMSA Trap ID
120100
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*         ✔*

VDR33

Message
Background initialization was cancelled for arg1 .
Arguments
arg1 = virtual disk
Detailed Description
Background initialization of a virtual disk was cancelled. This may be due to user action. This operation may automatically restart.
Recommended Response Action
No response action is required.
Category
Storage (VDR = Virtual Disk)
Severity
Severity 3 (Informational)
Trap/EventID
4355
OMSA Event ID
2128
OMSA Trap ID
120100
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*         ✔*

VDR34

Message
Background initialization failed for arg1 .
Arguments
arg1 = virtual disk
Detailed Description
Background initialization of a virtual disk failed.
Recommended Response Action
Run a consistency check on the virtual disk. If that fails, check the health of the member drives of the virtual disk and then recreate.
Category
Storage (VDR = Virtual Disk)
Severity
Severity 1 (Critical)
Trap/EventID
4353
OMSA Event ID
2129
OMSA Trap ID
120400
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*         ✔*

VDR35

Message
Background initialization has completed for arg1 .
Arguments
arg1 = virtual disk
Detailed Description
Background initialization of a virtual disk completed.
Recommended Response Action
No response action is required.
Category
Storage (VDR = Virtual Disk)
Severity
Severity 3 (Informational)
Trap/EventID
4355
OMSA Event ID
2130
OMSA Trap ID
120100
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*         ✔*

VDR36

Message
arg1 initialization is in-progress arg2 .
Arguments
arg1 = VD Name, arg2 = progresspercent
Detailed Description
Virtual disk initialization is in-progress. This alert is provided for informational purposes.
Recommended Response Action
No response action is required.
Category
Storage (VDR = Virtual Disk)
Severity
Severity 3 (Informational)
Trap/EventID
4355
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*         ✔*

VDR37

Message
Dead disk segments are restored on arg1 .
Arguments
arg1 = VD Name
Detailed Description
Disk space that was formerly "dead" or inaccessible to a redundant virtual disk has been restored. This alert is provided for informational purposes.
Recommended Response Action
No response action is required.
Category
Storage (VDR = Virtual Disk)
Severity
Severity 3 (Informational)
Trap/EventID
4355
OMSA Event ID
2140
OMSA Trap ID
120100
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*         ✔*

VDR38

Message
arg1 is renamed.
Arguments
arg1 = VD Name
Detailed Description
A user renamed a virtual disk. This alert is provided for informational purposes.
Recommended Response Action
No response action is required.
Category
Storage (VDR = Virtual Disk)
Severity
Severity 3 (Informational)
Trap/EventID
4355
OMSA Event ID
2159
OMSA Trap ID
120100
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*         ✔*

VDR39

Message
The check consistency has made corrections and completed for arg1 .
Arguments
arg1 = VD name
Detailed Description
The virtual disk check consistency has identified issues and made corrections. For example, the check consistency may have encountered a bad disk block and remapped the disk block to restore data consistency. This alert is provided for informational purposes.
Recommended Response Action
No response action is required. As a precaution, monitor the Log for other errors related to this virtual disk. If problems persist, contact technical support.
Category
Storage (VDR = Virtual Disk)
Severity
Severity 3 (Informational)
Trap/EventID
4355
OMSA Event ID
2192
OMSA Trap ID
120300
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*         ✔*

VDR4

Message
arg1 was created.
Arguments
arg1 = virtual disk
Detailed Description
This message is generated after a virtual disk was created on a controller.
Recommended Response Action
No response action is required.
Category
Storage (VDR = Virtual Disk)
Severity
Severity 3 (Informational)
Trap/EventID
4355
OMSA Event ID
2053
OMSA Trap ID
120100
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*         ✔*

VDR40

Message
The reconfiguration of arg1 has resumed.
Arguments
arg1 = virtual disk
Detailed Description
This message is generated after the reconfiguration of a virtual disk resumes.
Recommended Response Action
No response action is required.
Category
Storage (VDR = Virtual Disk)
Severity
Severity 3 (Informational)
Trap/EventID
4355
OMSA Event ID
2193
OMSA Trap ID
120100
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*         ✔*

VDR41

Message
arg1 read policy has changed.
Arguments
arg1 = VD Name
Detailed Description
This alert is provided for informational purposes.
Recommended Response Action
No response action is required.
Category
Storage (VDR = Virtual Disk)
Severity
Severity 3 (Informational)
Trap/EventID
4355
OMSA Event ID
2194
OMSA Trap ID
120100
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*         ✔*

VDR42

Message
Dedicated hot spare assigned physical disk arg1 .
Arguments
arg1 = args
Detailed Description
This alert is provided for informational purposes.
Recommended Response Action
No response action is required.
Category
Storage (VDR = Virtual Disk)
Severity
Severity 3 (Informational)
Trap/EventID
4355
OMSA Event ID
2195
OMSA Trap ID
120100
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*         ✔*

VDR43

Message
Dedicated hot spare unassigned physical disk arg1 .
Arguments
arg1 = args
Detailed Description
This alert is provided for informational purposes.
Recommended Response Action
No response action is required.
Category
Storage (VDR = Virtual Disk)
Severity
Severity 3 (Informational)
Trap/EventID
4355
OMSA Event ID
2196
OMSA Trap ID
120100
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*         ✔*

VDR44

Message
arg1 disk cache policy has changed.
Arguments
arg1 = VD Name
Detailed Description
This alert is provided for informational purposes.
Recommended Response Action
No response action is required.
Category
Storage (VDR = Virtual Disk)
Severity
Severity 3 (Informational)
Trap/EventID
4355
OMSA Event ID
2199
OMSA Trap ID
120100
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*         ✔*

VDR45

Message
arg1 blink has been initiated.
Arguments
arg1 = VD Name
Detailed Description
This alert is provided for informational purposes.
Recommended Response Action
No response action is required.
Category
Storage (VDR = Virtual Disk)
Severity
Severity 3 (Informational)
Trap/EventID
4355
OMSA Event ID
2244
OMSA Trap ID
120100
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*         ✔*

VDR46

Message
arg1 blink has ceased.
Arguments
arg1 = VD Name
Detailed Description
This alert is provided for informational purposes.
Recommended Response Action
No response action is required.
Category
Storage (VDR = Virtual Disk)
Severity
Severity 3 (Informational)
Trap/EventID
4355
OMSA Event ID
2245
OMSA Trap ID
120100
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*         ✔*

VDR47

Message
A disk media error was corrected on arg1 .
Arguments
arg1 = virtual disk
Detailed Description
A disk media error was detected while the controller was completing a background task. A bad disk block was identified. The disk block was remapped.
Recommended Response Action
Check the Lifecycle log for information related to members of this virtual disk.
Category
Storage (VDR = Virtual Disk)
Severity
Severity 3 (Informational)
Trap/EventID
4355
OMSA Event ID
2280
OMSA Trap ID
120100
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*         ✔*

VDR48

Message
arg1 has inconsistent data.
Arguments
arg1 = VD Name
Detailed Description
This alert is provided for informational purposes. The virtual disk has inconsistent data. This may be caused when a power loss or system shutdown occurs while data is being written to the virtual disk.
Recommended Response Action
No response action is required.
Category
Storage (VDR = Virtual Disk)
Severity
Severity 3 (Informational)
Trap/EventID
4355
OMSA Event ID
2281
OMSA Trap ID
120100
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*         ✔*

VDR49

Message
arg1 is permanently degraded.
Arguments
arg1 = VD Name
Detailed Description
A redundant virtual disk has lost redundancy. This may occur when the virtual disk suffers the failure of more than one physical disk. In this case, both the source physical disk and the target disk with redundant data have failed. A rebuild is not possible because there is no longer redundancy.
Recommended Response Action
Replace the failed disks and restore from backup.
Category
Storage (VDR = Virtual Disk)
Severity
Severity 1 (Critical)
Trap/EventID
4353
OMSA Event ID
2310
OMSA Trap ID
120400
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*          

VDR5

Message
arg1 was deleted.
Arguments
arg1 = virtual disk
Detailed Description
The controller removed a virtual disk. This is due to a delete virtual disk operation, a reset configuration operation, or the removal of every physical disk that was a member of the virtual disk.
Recommended Response Action
No response action is required.
Category
Storage (VDR = Virtual Disk)
Severity
Severity 3 (Informational)
Trap/EventID
4355
OMSA Event ID
2054
OMSA Trap ID
120100
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*          

VDR50

Message
Background Initialization (BGI) completed with uncorrectable errors on arg1 .
Arguments
arg1 = virtual disk
Detailed Description
The background initialization task encountered errors that cannot be corrected. The virtual disk contains physical disks that have unusable disk space or disk errors that cannot be corrected.
Recommended Response Action
Review other messages to identify whether the physical disk that has errors. If the virtual disk is redundant, you can replace the physical disk and continue using the virtual disk. If the virtual disk is non-redundant, you need to recreate the virtual disk after replacing the physical disk. After replacing the physical disk, run a consistency check to verify the data.
Category
Storage (VDR = Virtual Disk)
Severity
Severity 1 (Critical)
Trap/EventID
4353
OMSA Event ID
2340
OMSA Trap ID
120400
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*          

VDR51

Message
The consistency check process made corrections and completed on arg1 .
Arguments
arg1 = virtual disk
Detailed Description
The consistency check completed on the virtual disk after making corrections.
Recommended Response Action
No response action is required.
Category
Storage (VDR = Virtual Disk)
Severity
Severity 3 (Informational)
Trap/EventID
4355
OMSA Event ID
2341
OMSA Trap ID
120100
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*          

VDR52

Message
The consistency check found inconsistent parity data on arg1 .
Arguments
arg1 = virtual disk
Detailed Description
The data on physical disk members of the virtual disk does not match. Redundancy may be lost.
Recommended Response Action
Rerun the consistency check task. If you receive this message again, verify the health of the physical disks included in the virtual disk. See the storage hardware documentation for more information. Review messages for significant messages related to the physical disks. If a physical disk has a problem, replace it and restore from a backup copy. Contact technical support if the issue persists.
Category
Storage (VDR = Virtual Disk)
Severity
Severity 2 (Warning)
Trap/EventID
4354
OMSA Event ID
2342
OMSA Trap ID
120300
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*          

VDR53

Message
The consistency check logging of inconsistent parity data is disabled for arg1 .
Arguments
arg1 = virtual disk
Detailed Description
The consistency check can no longer report errors in the parity data.
Recommended Response Action
See the storage hardware documentation for more information on consistency check operation. Contact technical support.
Category
Storage (VDR = Virtual Disk)
Severity
Severity 2 (Warning)
Trap/EventID
4354
OMSA Event ID
2343
OMSA Trap ID
120300
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*          

VDR54

Message
arg1 initialization is terminated.
Arguments
arg1 = VD Name
Detailed Description
You have cancelled the virtual disk initialization.
Recommended Response Action
Restart the initialization.
Category
Storage (VDR = Virtual Disk)
Severity
Severity 2 (Warning)
Trap/EventID
4354
OMSA Event ID
2344
OMSA Trap ID
120300
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*          

VDR55

Message
arg1 initialization has failed.
Arguments
arg1 = VD Name
Detailed Description
The controller cannot communicate with attached devices. A disk may be removed or contain errors. Cables may also be loose or defective.
Recommended Response Action
Verify the health of attached devices. Review the Alert Log for significant events. Make sure the cables are attached securely. See the Cables Attached Correctly section for more information on checking the cables.
Category
Storage (VDR = Virtual Disk)
Severity
Severity 1 (Critical)
Trap/EventID
4353
OMSA Event ID
2345
OMSA Trap ID
120400
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*          

VDR56

Message
Redundancy of arg1 has been degraded.
Arguments
arg1 = virtual disk
Detailed Description
This message occurs when a physical disk in the disk group was removed or when a physical disk included in a redundant virtual disk fails. Because the virtual disk is redundant (uses mirrored or parity information) and only one physical disk has failed, the virtual disk can be rebuilt. Typically, the virtual disk (E.g. RAID 6) has multiple redundant disks and there is a problem with one of them.
Recommended Response Action
Replace the missing or failed physical disk.
Category
Storage (VDR = Virtual Disk)
Severity
Severity 3 (Informational)
Trap/EventID
4355
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*          

VDR57

Message
Background Initialization in arg1 corrected medium error.
Arguments
arg1 = VD Name
Detailed Description
A disk media error was detected while the controller was completing a background task. A bad disk block was identified. The disk block has been remapped.
Recommended Response Action
Consider replacing the disk. If you receive this alert frequently, ensure to replace the disk. It is recommended to routinely back up your data.
Category
Storage (VDR = Virtual Disk)
Severity
Severity 3 (Informational)
Trap/EventID
4355
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC      
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*          

VDR58

Message
Bad block medium error is detected at block arg1 on arg2 .
Arguments
arg1 = args, arg2 = VD Name
Detailed Description
Virtual disk bad blocks are due to presence of unrecoverable bad blocks on one or more member physical disks.
Recommended Response Action
Recovering a physical disk bad block depends on the RAID level and state of the virtual disk. If a virtual disk is redundant, the controller can recover a bad block on a physical disk. If a virtual disk is not redundant, then the physical disk bad block results in a virtual disk bad block.
Category
Storage (VDR = Virtual Disk)
Severity
Severity 1 (Critical)
Trap/EventID
4353
OMSA Event ID
2387
OMSA Trap ID
120400
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*          

VDR59

Message
arg1 security has failed.
Arguments
arg1 = VD Name
Detailed Description
This alert message occurs if virtual disk security has failed.
Recommended Response Action
No response action is required.
Category
Storage (VDR = Virtual Disk)
Severity
Severity 3 (Informational)
Trap/EventID
4355
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*          

VDR6

Message
arg1 configuration has changed.
Arguments
arg1 = VD Name
Detailed Description
This alert is provided for informational purposes.
Recommended Response Action
No response action is required.
Category
Storage (VDR = Virtual Disk)
Severity
Severity 3 (Informational)
Trap/EventID
4355
OMSA Event ID
2055
OMSA Trap ID
120100
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*          

VDR60

Message
arg1 initialization is in progress on arg2 .
Arguments
arg1 = initialization type, arg2 = virtual disk
Detailed Description
There are two modes of virtual disk initialization, full and fast. This initialisation type identified in the message is running on the virtual disk identified in the message.
Recommended Response Action
No response action is required.
Category
Storage (VDR = Virtual Disk)
Severity
Severity 3 (Informational)
Trap/EventID
4355
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC              

VDR7

Message
arg1 has failed.
Arguments
arg1 = virtual disk
Detailed Description
One or more physical disks included in the virtual disk have failed. If the virtual disk is non-redundant (does not use mirrored or parity data), then the failure of a single physical disk can cause the virtual disk to fail. If the virtual disk is redundant, then more physical disks have failed than you can rebuild using mirrored or parity information.
Recommended Response Action
Create a new virtual disk and restore from a backup.
Category
Storage (VDR = Virtual Disk)
Severity
Severity 1 (Critical)
Trap/EventID
4353
OMSA Event ID
2056
OMSA Trap ID
120400
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*          

VDR8

Message
arg1 has become degraded.
Arguments
arg1 = virtual disk
Detailed Description
This message occurs when a physical disk in the disk group was removed or when a physical disk included in a redundant virtual disk fails. Because the virtual disk is redundant (uses mirrored or parity information) and only one physical disk has failed, the virtual disk can be rebuilt.
Recommended Response Action
Configure a hot spare for the virtual disk if it is not already configured. Rebuild the virtual disk. If a physical disk was removed from the disk group, either replace the disk or restore the original disk.
Category
Storage (VDR = Virtual Disk)
Severity
Severity 2 (Warning)
Trap/EventID
4354
OMSA Event ID
2057
OMSA Trap ID
120300
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*          

VDR9

Message
arg1 consistency check has started.
Arguments
arg1 = virtual disk
Detailed Description
A consistency check operation on a virtual disk has started.
Recommended Response Action
No response action is required.
Category
Storage (VDR = Virtual Disk)
Severity
Severity 3 (Informational)
Trap/EventID
4355
OMSA Event ID
2058
OMSA Trap ID
120100
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*          

VDR91

Message
Consistency check for arg1 has detected multiple uncorrectable medium errors.
Arguments
arg1 = virtual disk
Detailed Description
This message occurs if there are medium errors in the physical drives.
Recommended Response Action
Replace the failed drives.
Category
Storage (VDR = Virtual Disk)
Severity
Severity 1 (Critical)
Trap/EventID
4353
OMSA Event ID
2396
OMSA Trap ID
120400
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*          

VDR92

Message
Consistency check for arg1 has completed with uncorrectable errors.
Arguments
arg1 = virtual disk
Detailed Description
This message occurs if there are medium errors in the physical drives.
Recommended Response Action
Replace the failed drives.
Category
Storage (VDR = Virtual Disk)
Severity
Severity 1 (Critical)
Trap/EventID
4353
OMSA Event ID
2397
OMSA Trap ID
120400
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*          

VDR93

Message
arg1 bad block medium error is cleared.
Arguments
arg1 = VD Name
Detailed Description
This alert message occurs if there are medium errors in the physical drives.
Recommended Response Action
No response action is required.
Category
Storage (VDR = Virtual Disk)
Severity
Severity 3 (Informational)
Trap/EventID
4355
OMSA Event ID
2389
OMSA Trap ID
120100
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*          

VDR94

Message
Controller preserved cache was recovered for arg1 .
Arguments
arg1 = virtual disk
Detailed Description
This message occurs if the controller pinned cache is recovered.
Recommended Response Action
No response action is required.
Category
Storage (VDR = Virtual Disk)
Severity
Severity 3 (Informational)
Trap/EventID
4355
OMSA Event ID
2381
OMSA Trap ID
75100
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*          

VDR95

Message
Unable to log block arg1 .Bad block table on arg2 is full.
Arguments
arg1 = arg, arg2 = VD Name
Detailed Description
This alert message occurs if the virtual disk has bad blocks.
Recommended Response Action
Replace the disk in the Virtual disk, generating this alert and restore from backup. You may have lost data.
Category
Storage (VDR = Virtual Disk)
Severity
Severity 3 (Informational)
Trap/EventID
4355
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*          

VDR96

Message
Bad block table on arg1 is 80 percent full.
Arguments
arg1 = virtual disk
Detailed Description
This message occurs if the virtual disk has bad blocks.
Recommended Response Action
Replace the disk in the Virtual disk, generating this message.
Category
Storage (VDR = Virtual Disk)
Severity
Severity 3 (Informational)
Trap/EventID
4355
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*          

VDR97

Message
Patrol Read corrected a media error on arg1 .
Arguments
arg1 = VD Name
Detailed Description
The Patrol Read task has encountered an error such as a bad disk block and remapped data to correct the error.
Recommended Response Action
No response action is required.
Category
Storage (VDR = Virtual Disk)
Severity
Severity 3 (Informational)
Trap/EventID
4355
OMSA Event ID
2271
OMSA Trap ID
90100
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*          

VDR98

Message
arg1 has switched active controllers. Its active path is now through arg2 .
Arguments
arg1 = virtual disk, arg2 = controller name
Detailed Description
The virtual disk identified in the message has changed active paths. This can be because of an attempt to optimize the throughput of the system or it could be because of a controller failover.
Recommended Response Action
No response action is required.
Category
Storage (VDR = Virtual Disk)
Severity
Severity 3 (Informational)
Trap/EventID
4355
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*          

VDR99

Message
arg1 is unavailable because of an ID conflict in the fault-tolerant pair.
Arguments
arg1 = virtual disk
Detailed Description
The virtual disk identified in the message cannot be used because of an ID conflict with another virtual disk.
Recommended Response Action
Power cycle the system chassis to restore the virtual disk. If this does not correct the problem then contact your service provider.
Category
Storage (VDR = Virtual Disk)
Severity
Severity 2 (Warning)
Trap/EventID
4354
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*         ✔*

Rate this content

Accurate
Useful
Easy to understand
Was this article helpful?
0/3000 characters
  Please provide ratings (1-5 stars).
  Please provide ratings (1-5 stars).
  Please provide ratings (1-5 stars).
  Please select whether the article was helpful or not.
  Comments cannot contain these special characters: <>()\