Disables all the functionality of
Power Manager on OpenManage Enterprise. The REST APIs specific to
Power Manager are also disabled.
Prerequisites
Ensure that the following prerequisites are met:
The Emergency Power Reduction (EPR) is not enabled on the device. View the EPR status of all devices and groups on the
Emergency Power Reduction page.
There are no active policies.
About this task
NOTE Disabling a plugin in OpenManage Enterprise restarts the appliance services.
Steps
Launch OpenManage Enterprise.
Click
Application Settings
> Console and Extensions.
The
Console and Extensions page is displayed.
In the
Power Manager section, click the
Disable option.
The
Disable page is displayed.
If you are using OpenManage Enterprise version 3.4 or earlier, click
Enable Extension.
If you are using OpenManage Enterprise version 3.5, click
Enable Plugin.
The
Confirmation page is displayed.
On the
Confirmation page, select the
I agree that I have captured the snapshot of the OM Enterprise appliance prior to the upgrade option, and then click
Confirm Disable.
Information about the number of users using OpenManage Enterprise and details about the jobs running are displayed.
Results
After disabling
Power Manager, you cannot see any information or pages that are related to
Power Manager in OpenManage Enterprise.
Data is not available for the Topic
Please provide ratings (1-5 stars).
Please provide ratings (1-5 stars).
Please provide ratings (1-5 stars).
Please select whether the article was helpful or not.
Comments cannot contain these special characters: <>()\