Removing integrated storage controller card

Prerequisites

  1. Follow the safety guidelines listed in Safety instructions.
  2. Follow the procedure listed in Before working inside your system.
  3. Remove the air shroud.
  4. Remove the expansion card riser 1.

Steps

  1. Using Phillips #2 screwdriver, loosen the screws that secure the integrated storage controller cable to the system board.
  2. Lift the integrated storage controller cable away from the integrated storage controller.
    Figure 1. Removing integrated storage controller cable
    This image shows removing integrated storage controller cable.
  3. Lift one end of the card and angle it to disengage the card from the integrated storage controller card holder on the system board.
  4. Lift the card out of the system.
  5. Hold the interposer board by its edges, and pull the board until the connector on the board disengages from the connector on the system board.
    Figure 2. Removing integrated storage controller card
    This image shows removing the integrated storage controller card.