Skip to main content
  • Place orders quickly and easily
  • View orders and track your shipping status
  • Enjoy members-only rewards and discounts
  • Create and access a list of your products
  • Manage your Dell EMC sites, products, and product-level contacts using Company Administration.

Dell PowerVault ME4 Series Storage System Deployment Guide

Module LEDs

Module LEDs pertain to controller modules and IOMs.

Controller module LEDs

Use the controller module LEDs on the face plate to monitor the status of a controller module.
Table 1. Controller module LED states
CRU OK (Green) CRU Fault (Amber) External host port activity (Green) Status
On Off Controller module OK
Off On Controller module fault – see “Replacing a controller module” in the Dell PowerVault ME4 Series Storage System Owner’s Manual
Off No external host port connection
On External host port connection – no activity
Blinking External host port connection – activity
Blinking System is booting

Actions:

  • If the CRU OK LED is blinking, wait for the system to boot.
  • If the CRU OK LED is off, and the controller module is powered on, the module has failed.
    • Check that the controller module is fully inserted and latched in place, and that the enclosure is powered on.
    • Check the event log for specific information regarding the failure.
  • If the CRU Fault LED is on, a fault condition is detected.
    • Restart the controller module from the partner controller module using the PowerVault Manager or CLI.
    • If the restart does not resolve the fault, remove the controller module and reinsert it.
  • If the previous actions do not resolve the fault, contact your supplier for assistance. Controller module replacement may be necessary.

IOM LEDs

Use the IOM LEDs on the face plate to monitor the status of an IOM .

Table 2. IOM LED states
CRU OK (Green) CRU Fault (Amber) External host port activity (Green) Status
On Off Controller module OK
Off On IOM module fault – see “Replacing an IOM” in the Dell PowerVault ME4 Series Storage System Owner’s Manual
Off No external host port connection
On HD mini-SAS port connection – no activity
Blinking HD mini-SAS port connection – activity
Blinking EBOD VPD error

Actions:

  • If the CRU OK LED is off, and the IOM is powered on, the module has failed.
    • Check that the IOM is fully inserted and latched in place, and that the enclosure is powered on.
    • Check the event log for specific information regarding the failure.
  • If the CRU Fault LED is on, a fault condition is detected.
    • Restart this IOM using the PowerVault Manager or CLI.
    • If the restart does not resolve the fault, remove the IOM and reinsert it.
  • If the previous actions do not resolve the fault, contact your supplier for assistance. IOM replacement may be necessary.