Module LEDs
Module LEDs pertain to controller modules and IOMs.
Controller module LEDs
Use the controller module LEDs on the face plate to monitor the status of a controller module.
Table 1. Controller module LED states
CRU OK (Green)
|
CRU Fault (Amber)
|
External host port activity (Green)
|
Status
|
On
|
Off
|
—
|
Controller module OK
|
Off
|
On
|
—
|
Controller module fault – see “Replacing a controller module” in the
Dell PowerVault ME4 Series Storage System Owner’s Manual
|
—
|
—
|
Off
|
No external host port connection
|
—
|
—
|
On
|
External host port connection – no activity
|
—
|
—
|
Blinking
|
External host port connection – activity
|
Blinking
|
—
|
—
|
System is booting
|
Actions:
- If the CRU OK LED is blinking, wait for the system to boot.
- If the CRU OK LED is off, and the controller module is powered on, the module has failed.
- Check that the controller module is fully inserted and latched in place, and that the enclosure is powered on.
- Check the event log for specific information regarding the failure.
- If the CRU Fault LED is on, a fault condition is detected.
- Restart the controller module from the partner controller module using the
PowerVault Manager or CLI.
- If the restart does not resolve the fault, remove the controller module and reinsert it.
- If the previous actions do not resolve the fault, contact your supplier for assistance. Controller module replacement may be necessary.
IOM LEDs
Use the IOM LEDs on the face plate to monitor the status of an IOM .
Table 2. IOM LED states
CRU OK (Green)
|
CRU Fault (Amber)
|
External host port activity (Green)
|
Status
|
On
|
Off
|
—
|
Controller module OK
|
Off
|
On
|
—
|
IOM module fault – see “Replacing an IOM” in the
Dell PowerVault ME4 Series Storage System Owner’s Manual
|
—
|
—
|
Off
|
No external host port connection
|
—
|
—
|
On
|
HD mini-SAS port connection – no activity
|
—
|
—
|
Blinking
|
HD mini-SAS port connection – activity
|
Blinking
|
—
|
—
|
EBOD VPD error
|
Actions:
- If the CRU OK LED is off, and the IOM is powered on, the module has failed.
- Check that the IOM is fully inserted and latched in place, and that the enclosure is powered on.
- Check the event log for specific information regarding the failure.
- If the CRU Fault LED is on, a fault condition is detected.
- Restart this IOM using the
PowerVault Manager or CLI.
- If the restart does not resolve the fault, remove the IOM and reinsert it.
- If the previous actions do not resolve the fault, contact your supplier for assistance. IOM replacement may be necessary.