The following high severity issues are resolved in this release:
Issue | Functional area | Description |
---|---|---|
SCOS-63413 | Data Reduction | Deduplication page manager (DPM) pages with empty deduplication map entries might be created after a power outage that causes the pagepool to go down and controllers to reset. |
SCOS-62992 | Hardware | An issue with consecutive calls to the Get Device ID command in the Chelsio T4 driver might cause a controller to reset. |
SCOS-62786 | Hardware | An issue with consecutive calls to the Get Device ID command in the QLA24xx driver might cause a controller to reset. |
SCOS-60242 | Hardware | The drive status indicator might remain lit after a failed drive is replaced in an enclosure. |
SCOS-63198 | Licensing, SupportAssist, and Updating | The SCSI command log that is collected from a storage system is no longer useful for troubleshooting system enclosure issues. |
SCOS-63348 | Live Volume and Replication | The Configured Space value for Remote Storage Centers might be incorrect if there are multiple mappings to the same volume. |
SCOS-63566 | Storage Management | Data Progression and snapshot schedules might be delayed when SupportAssist sends Storage Center data to CloudIQ. |
SCOS-63555 | Storage Management | Compressed core files might be truncated when core segments are larger than 4 GB and the coretype is set to full on a storage system. |
SCOS-63405 | Storage Management | A controller might reset because of IORPs with a null pointer. |
SCOS-63305 | Storage Management | A Cache Process Memory Move Request failure might cause a controller to reset on SCv2000 series, SCv3000 series, SC4020, SC5020, and SC7020 storage systems. |
SCOS-62295 | Storage Management | A controller might reset because of a system timer calculation issue. |
SCOS-61565 | Storage Management | Leaked SGPayloads containing PITC Table or other MLTable metadata might cause a controller to reset. |
SCOS-61178 | Storage Management | During the restriping of tier 1 storage, the Add Spaces command may fail to occur and writes could spill over into tier 2 and tier 3 resulting performance issues. |
SCOS-56379 | Storage Management | A storage system might display cable alerts for back-end SAS cabling after it is upgraded to Storage Center 7.3.11 or later. |