BOOT Event Messages

BOOT001

Message
The command was successful.
Detailed Description
The command was successful.
Recommended Response Action
No response action is required.
Category
Configuration (BOOT = BOOT Control)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

BOOT002

Message
Resource allocation error
Detailed Description
Unable to allocate required memory to perform the operation
Recommended Response Action
Power cycle system and reapply firmware packages for Lifecycle Controller and iDRAC.
Category
Configuration (BOOT = BOOT Control)
Severity
Severity 2 (Warning)
No alerts are applicable for this message

BOOT003

Message
Method not supported
Detailed Description
This operation is not supported on the current configuration.
Recommended Response Action
This operation is not supported on the current configuration, check documentation and try again
Category
Configuration (BOOT = BOOT Control)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

BOOT004

Message
Invalid number of Boot Source arguments
Detailed Description
An invalid number of source arguments was passed to the method.
Recommended Response Action
Check documentation and try again (details)
Category
Configuration (BOOT = BOOT Control)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

BOOT005

Message
Missing required parameter.
Detailed Description
One or more of the invoked methods required parameters are missing.
Recommended Response Action
Check documentation for the method in question and try again.
Category
Configuration (BOOT = BOOT Control)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

BOOT006

Message
Invalid Boot Source InstanceID
Detailed Description
One or more of the Boot Source instance IDs does not contain valid data.
Recommended Response Action
Verify that all of the Boot Source instance IDs being entered are as they appear in the DCIM_BootSourceSetting enumeration.
Category
Configuration (BOOT = BOOT Control)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

BOOT007

Message
Boot Source does not belong to specified Boot Configuration
Detailed Description
One or more of the Boot Source instance IDs does not belong to the affected Boot Configuration.
Recommended Response Action
ChangeBootOrderByInstanceID only accepts Boot Sources from the impacted Boot Configuration. Verify that all source arguments belong to the desired Boot Configuration.
Category
Configuration (BOOT = BOOT Control)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

BOOT008

Message
Source argument contains more devices than are present on the system
Detailed Description
More source arguments were provided than are available for the impacted Boot Configuration.
Recommended Response Action
Verify that all of the Boot Source instance IDs being entered are as they appear in the DCIM_BootSourceSetting enumeration.
Category
Configuration (BOOT = BOOT Control)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

BOOT009

Message
Boot Sources cannot be found for this Boot Configuration
Detailed Description
No Boot Sources could be found for the desired Boot Configuration.
Recommended Response Action
Verify that Boot Sources for the indicated Boot Configuration are displaying when enumerating DCIM_BootSourceSetting. Power cycle system and reapply firmware packages for Lifecycle Controller and iDRAC.
Category
Configuration (BOOT = BOOT Control)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

BOOT010

Message
Could not locate vFlash partition index
Detailed Description
The provided vFlash partition index could not be found on the system.
Recommended Response Action
Verify that a vFlash partition with the desired index exists on the System.
Category
Configuration (BOOT = BOOT Control)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

BOOT011

Message
Failed to set vFlash partition for one time boot
Detailed Description
The provided vFlash partition could not be set for one time boot.
Recommended Response Action
Power cycle system and reapply firmware packages for Lifecycle Controller and iDRAC.
Category
Configuration (BOOT = BOOT Control)
Severity
Severity 2 (Warning)
No alerts are applicable for this message

BOOT012

Message
Job started to attach and set vFlash SD card partition for OneTime boot.
Detailed Description
A job was created to configure a OneTime boot to the specified vFlash SD card partition. If this partition was not attached to the system, the job attaches it as well.
Recommended Response Action
No response action is required.
Category
Configuration (BOOT = BOOT Control)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

BOOT013

Message
Cannot make changes to non-active boot list.
Detailed Description
The boot list is currently not active. Changes cannot be made to boot list that is not active.
Recommended Response Action
Alter boot mode to set the boot list active and retry the operation.
Category
Configuration (BOOT = BOOT Control)
Severity
Severity 2 (Warning)
No alerts are applicable for this message

BOOT014

Message
Virtual media not ready.
Detailed Description
The systems SD card has been removed or is in use.
Recommended Response Action
Verify that the SD card is inserted and that another operation is not in progress, and try again.
Category
Configuration (BOOT = BOOT Control)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

BOOT015

Message
Set operation successful for the boot partition.
Detailed Description
The boot partition configuration request was successful. An unattached vFlash partition was configured for one-time boot using the ChangeBootOrderByInstanceID method. The method creates a job (to attach the vFlash partition and set the partition for one-time boot.
Recommended Response Action
No response action is required.
Category
Configuration (BOOT = BOOT Control)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

BOOT016

Message
Input source argument value for the boot device is incorrect or not found among the boot devices on the system.
Detailed Description
The input source argument value referring to the boot device is incorrect or empty. The boot device identifier must match the InstanceID for the BootSourceSetting instance that represents the boot device.
Recommended Response Action
Use the correct source argument value for the boot device and retry the operation.
Category
Configuration (BOOT = BOOT Control)
Severity
Severity 2 (Warning)
No alerts are applicable for this message

BOOT017

Message
Source argument does not support enable or disable mode.
Detailed Description
The boot device(s) specified in the source argument used in the operation cannot be enabled or disabled. This behavior applies to BCV devices and one-time boot.
Recommended Response Action
Refer to the documentation on validity of operation for the boot device specified. For more information on the operation, see Lifecycle Controller-Remote Services documentation.
Category
Configuration (BOOT = BOOT Control)
Severity
Severity 2 (Warning)
No alerts are applicable for this message

BOOT018

Message
Specified Boot Control List is read-only
Detailed Description
The Boot Control List specified in the operation is read-only and cannot be modified.
Recommended Response Action
Refer to the documentation on validity of operation for the Boot Control List specified. For more information on the operation, see Lifecycle Controller-Remote Services documentation.
Category
Configuration (BOOT = BOOT Control)
Severity
Severity 2 (Warning)
No alerts are applicable for this message

BOOT8500

Message
Unable to change the BIOS boot order for the Server arg1
Arguments
arg1 = slot number
Detailed Description
Unable to change the BIOS boot order for the server because of a broken communication between the CMC and iDRAC, or iDRAC is rebooting.
Recommended Response Action
Reset iDRAC or wait until iDRAC reboots, and retry the operation.
Category
Configuration (BOOT = BOOT Control)
Severity
Severity 1 (Critical)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

Rate this content

Accurate
Useful
Easy to understand
Was this article helpful?
0/3000 characters
  Please provide ratings (1-5 stars).
  Please provide ratings (1-5 stars).
  Please provide ratings (1-5 stars).
  Please select whether the article was helpful or not.
  Comments cannot contain these special characters: <>()\