This document highlights minimum, recommended, and latest code versions for Dell Technologies Enterprise and Datacenter Infrastructure products. We carefully evaluate and monitor code deployment data to ensure that product releases meet our stringent expectations to provide our customers with reliable products and solutions.
Updated: May 11, 2026
ID: 000205512
Dell has a Customer Replaceable Unit (CRU) program for many of our hardware systems. The CRU program allows customers to replace designated hardware components. For a list of the hardware components that are designated as CRU for a specific hardware system, go to the Dell Warranty and Maintenance Page.
Updated: May 10, 2026
ID: 000187496
Many OneFS versions have obsolete timeout values configured for the drive stall timer. Increasing these values can help prevent unnecessary drive stall events.
Updated: May 11, 2026
ID: 000052229
On OneFS 8.0, the firmware update process fails if the BMC/CMC subsystem is unresponsive. Sometimes the warning event to indicate this condition is not generated.
Updated: May 11, 2026
ID: 000052217
After upgrading to 8.0.1.0, Mac clients are unable to view secondary mounted shares (but can still view first mounted share/volume) and receive a denial of access.
Updated: May 11, 2026
ID: 000159994
The OneFS event 'Physical Memory low (expected xxxGB, found yyyGB)' indicates a defective DIMM module in the node, or a problem with the node's configuration.
Updated: May 11, 2026
ID: 000032680
Isilon GEN 6: HW_INFINITY_COMPUTE_FAULT: Compute node fault detected (User Correctable) - Event ID: 900160003
Updated: May 11, 2026
ID: 000187309
Upon upgrading OneFS, the isi_avscan_d daemon is consuming CPU, affecting node performance.
Updated: May 11, 2026
ID: 000438691
PowerScale Info Hub for OneFS 9.14.0.0 documentation
Updated: May 11, 2026
ID: 000449282
Gen6 node fails to boot during the PSI configuration phase.
Updated: May 11, 2026
ID: 000191007
Configuring automated log-upload on a weekly basis
Updated: May 11, 2026
ID: 000190875
PowerScale Isilon OneFS Event notification: Cluster-1: The cluster is running low on free space: free space (1.99xxx%) < job-configuration core.free_blocks_pct_threshold_lo (2%). - Event ID: 400100007
Updated: May 11, 2026
ID: 000356789
This article will help to remove the old entries of a child domain that is already decommissioned on the AD/DNS server.
Updated: May 11, 2026
ID: 000190365
PowerScale OneFS Event notification: One of the disk pools on your cluster is nearing, or has reached, maximum capacity.- Event ID: 100010015
Updated: May 11, 2026
ID: 000062564
How to properly delete snapshots from a cluster.
Updated: May 11, 2026
ID: 000008457
Case-sensitive HDFS platforms such as Cloudera or operating systems such as Linux may experience job failures due to changes in how OneFS reports resolved account names. After upgrading OneFS to 8.2.2.0, OneFS reports a case-preserved response from AD based on the SAMAccountName field. Linux or Cloudera clients reference a separate value from Active Directory that is stored in lowercase. The discrepancy can result in job failures submitted by impacted users. Clusters on OneFS 8.1.2.0 and lower do not display this behavior.
Updated: May 11, 2026
ID: 000190117
Below are steps to properly configure cascaded replication between Cluster_A, Cluster_B, and Cluster_C.
Updated: May 11, 2026
ID: 000189650
This article summarizes the commands to modify the user and/or group ownership in OneFS 8+
Updated: May 10, 2026
ID: 000189319
This KB affects Onefs8.2.2, Onefs 9.0 and Onefs 9.1
When running Smartpools Job, the progress only shows "Started". Status does not change from start to finish.
Updated: May 10, 2026
ID: 000189157
Documentation on OneFS configuration recommends using the OneFS SmartConnect DNS service to provide Round Robin DNS result via delegation, however in this configuration, if multiple DNS requests are received within 1 second of each other by the client DNS server, they will all receive the same IP address, causing connections to be unbalanced.
Updated: May 10, 2026
ID: 000188982
Using iperf to test bandwidth from a client to a OneFS cluster.
Updated: May 10, 2026
ID: 000188735
Nodes may panic with FAILED ASSERTION when fail to decode quota or snapshot attributes from extension blocks after upgrading to OneFS 9.2.0.0 or 9.2.1.0.
Updated: May 10, 2026
ID: 000188137
This article explains the issue that link status change for igb interface cannot be correctly reflected(found on OneFS 8.2, 9.0, 9.1, 9.2)
Updated: May 10, 2026
ID: 000187824
This article explains why the Backup Restartable Extension (BRE) is incompatible with the MultiStreaming feature in OneFS.
Updated: May 10, 2026
ID: 000187493
SyncIQ jobs can intermittently fail if there are non-networked nodes (NANON).
Updated: May 10, 2026
ID: 000187131
While configuring Cloudpool Account for the first time or modifying an existing one to use SSL, error is reported.
Updated: May 10, 2026
ID: 000187112
Encrypted SyncIQ policies immediately fail with sslv3 alert unsupported certificate SSL error.
Updated: May 09, 2026
ID: 000186531
During upgrade to 9.1.x or later upgrade stuck in committing.
During upgrade the error "isi_antivirus_post_commit.py Inform Failed to rename tmp_scans table as Scans table with error there is already another table or index with this name: Scans " appeared in isi_upgrade_logs.
Updated: May 09, 2026
ID: 000186093
This article explains how Users and Technical Support should manage "Node has Recovered from a panic" event or messages. Review all portions of the article before acting.
Updated: May 09, 2026
ID: 000184828
This article provides information about supported patches and service releases for OneFS and the HealthCheck system.
Updated: May 09, 2026
ID: 000184794