PDR Event Messages

PDR1

Message
arg1 copyback stopped for rebuild.
Arguments
arg1 = physical disk
Detailed Description
This message is generated after a copyback stops on a physical disk during a rebuild operation.
Recommended Response Action
Wait for rebuild to finish, then copyback should resume.
Category
Storage (PDR = Physical Disk)
Severity
Severity 2 (Warning)
Trap/EventID
4346
OMSA Event ID
2197
OMSA Trap ID
90300
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*          

PDR10

Message
arg1 rebuild has started.
Arguments
arg1 = physical disk
Detailed Description
This message is generated after a rebuild starts on a physical disk.
Recommended Response Action
No response action is required.
Category
Storage (PDR = Physical Disk)
Severity
Severity 3 (Informational)
Trap/EventID
4347
OMSA Event ID
2065
OMSA Trap ID
90100
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*          

PDR100

Message
Dedicated Hot Spare arg1 no longer useful for all arrays.
Arguments
arg1 = PD Name
Detailed Description
The controller is not able to communicate with a disk that is assigned as a dedicated hot spare. The disk may have been removed. There may also be a bad or loose cable.
Recommended Response Action
Verify that the disk is healthy and that it has not been removed. Check the cables. See the Cables Attached Correctly section for more information on checking the cables. If necessary, replace the disk and reassign the dedicated hot spare.
Category
Storage (PDR = Physical Disk)
Severity
Severity 2 (Warning)
Trap/EventID
4346
OMSA Event ID
2208
OMSA Trap ID
90300
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*          

PDR1000

Message
Drive arg1 is installed in disk drive bay arg2 .
Arguments
arg1 = number, arg2 = bay
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health (PDR = Physical Disk)
Severity
Severity 3 (Informational)
Trap/EventID
2299
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC              

PDR1001

Message
Fault detected on drive arg1 in disk drive bay arg2 .
Arguments
arg1 = number, arg2 = bay
Detailed Description
The controller detected a failure on the disk and has taken the disk offline.
Recommended Response Action
Remove and reseat the failed drive. If the problem persists, contact technical support. Refer to the product documentation to choose a convenient contact method.
Category
System Health (PDR = Physical Disk)
Severity
Severity 1 (Critical)
Trap/EventID
2297
LCD Message
Fault detected on drive <number> in disk drive bay <bay>. Check drive.
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC              

PDR1002

Message
A predictive failure detected on drive arg1 in disk drive bay arg2 .
Arguments
arg1 = number, arg2 = bay
Detailed Description
The controller received a SMART error from the drive. The drive is operational but needs replacement.
Recommended Response Action
The drive will need replacement at the next service window.
Category
System Health (PDR = Physical Disk)
Severity
Severity 2 (Warning)
Trap/EventID
2298
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC              

PDR1003

Message
Drive arg1 in disk drive bay arg2 is the hot-spare drive.
Arguments
arg1 = number, arg2 = bay
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health (PDR = Physical Disk)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

PDR1004

Message
Consistency check is in progress for drive arg1 in disk drive bay arg2 .
Arguments
arg1 = number, arg2 = bay
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health (PDR = Physical Disk)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

PDR1005

Message
Drive arg1 in disk drive bay arg2 is in the critical array.
Arguments
arg1 = number, arg2 = bay
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health (PDR = Physical Disk)
Severity
Severity 1 (Critical)
LCD Message
Drive <number> in disk drive bay <bay> is in the critical array. Replace drive.
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

PDR1006

Message
Drive arg1 in disk drive bay arg2 is in the failed array.
Arguments
arg1 = number, arg2 = bay
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health (PDR = Physical Disk)
Severity
Severity 1 (Critical)
LCD Message
Drive <number> in disk drive bay <bay> is in the failed array. Replace drive.
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

PDR1007

Message
Rebuild is in progress for drive arg1 in disk drive bay arg2 .
Arguments
arg1 = number, arg2 = bay
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health (PDR = Physical Disk)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

PDR1008

Message
Rebuild was aborted for drive arg1 in disk drive bay arg2 .
Arguments
arg1 = number, arg2 = bay
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health (PDR = Physical Disk)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

PDR101

Message
Global Hot Spare arg1 does not cover all arrays.
Arguments
arg1 = PD Name
Detailed Description
This alert message occurs if there are arrays not protected with a global hot spare.
Recommended Response Action
No response action is required.
Category
Storage (PDR = Physical Disk)
Severity
Severity 2 (Warning)
Trap/EventID
4346
OMSA Event ID
2209
OMSA Trap ID
90300
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*          

PDR1016

Message
Drive arg1 is removed from disk drive bay arg2 .
Arguments
arg1 = number, arg2 = bay
Detailed Description
The controller detected that the drive was removed.
Recommended Response Action
Verify drive installation. Remove and reseat the failed drive. If the problem persists, contact technical support. Refer to the product documentation to choose a convenient contact method.
Category
System Health (PDR = Physical Disk)
Severity
Severity 1 (Critical)
Trap/EventID
2297
LCD Message
Drive <number> removed from disk drive bay <bay>. Check drive.
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC              

PDR1017

Message
Drive arg1 in disk drive bay arg2 is operating normally.
Arguments
arg1 = number, arg2 = bay
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health (PDR = Physical Disk)
Severity
Severity 3 (Informational)
Trap/EventID
2299
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC              

PDR1019

Message
Drive arg1 in disk drive bay arg2 is no longer the hot-spare drive.
Arguments
arg1 = number, arg2 = bay
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health (PDR = Physical Disk)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

PDR102

Message
The Patrol Read operation was manually stopped before completion.
Detailed Description
The Patrol Read operation was manually stopped before completion.
Recommended Response Action
If desired, restart the Patrol Read operation at a later time.
Category
Storage (PDR = Physical Disk)
Severity
Severity 3 (Informational)
OMSA Event ID
2444
OMSA Trap ID
90100
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC        
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC            
CMC              

PDR1020

Message
Consistency check for drive arg1 in disk drive bay arg2 completed.
Arguments
arg1 = number, arg2 = bay
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health (PDR = Physical Disk)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

PDR1021

Message
Drive arg1 in disk drive bay arg2 is no longer in the critical array.
Arguments
arg1 = number, arg2 = bay
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health (PDR = Physical Disk)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

PDR1022

Message
Drive arg1 in disk drive bay arg2 is no longer in the failed array.
Arguments
arg1 = number, arg2 = bay
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health (PDR = Physical Disk)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

PDR1023

Message
Rebuild completed for drive arg1 in disk drive bay arg2 .
Arguments
arg1 = number, arg2 = bay
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health (PDR = Physical Disk)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

PDR1024

Message
Drive mismatch detected for drive arg1 in disk drive bay arg2 .
Arguments
arg1 = number, arg2 = bay
Detailed Description
The installed disk does not meet the array requirements, for example a SATA disk may not operate in an array containing SAS drives.
Recommended Response Action
Verify the disk meets the array requirements.
Category
System Health (PDR = Physical Disk)
Severity
Severity 1 (Critical)
Trap/EventID
2297
LCD Message
Drive mismatch detected for drive <number> in bay <bay>. Install correct drive type
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC              

PDR1025

Message
Drive mismatch corrected for drive arg1 in disk drive bay arg2 .
Arguments
arg1 = number, arg2 = bay
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health (PDR = Physical Disk)
Severity
Severity 3 (Informational)
Trap/EventID
2299
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC              

PDR103

Message
Cryptographic Erase operation is successfully completed on arg1 .
Arguments
arg1 = physical disk name
Detailed Description
Cryptographic Erase operation is successfully completed on the physical disk drive identified in the message.
Recommended Response Action
No response action is required.
Category
Storage (PDR = Physical Disk)
Severity
Severity 3 (Informational)
OMSA Event ID
2445
OMSA Trap ID
90100
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC          
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

PDR104

Message
The arg1 has turned off because the critical temperature threshold is exceeded.
Arguments
arg1 = PCIe solid state device name
Detailed Description
The PCIe solid state device identified in the message has turned off because the critical temperature threshold of the device was exceeded.
Recommended Response Action
Contact your service provider.
Category
Storage (PDR = Physical Disk)
Severity
Severity 1 (Critical)
OMSA Event ID
2441
OMSA Trap ID
90400
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC          
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

PDR105

Message
The physical disk drive arg1 is assigned as a dedicated hot-spare.
Arguments
arg1 = physical disk drive name
Detailed Description
The physical disk drive identified in the message is assigned as a dedicated hot-spare.
Recommended Response Action
No response action is required.
Category
Storage (PDR = Physical Disk)
Severity
Severity 3 (Informational)
Trap/EventID
4347
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC              

PDR106

Message
The physical disk drive arg1 is unassigned as a dedicated hot-spare.
Arguments
arg1 = physical disk drive name
Detailed Description
A physical disk identified in hte hot-spare that was assigned as a hot spare has been un-assigned and is no longer functioning as a hot spare. The physical disk was unassigned by a user or automatically by the storage management software. When one of the disks in a virtual disk fails, data is rebuilt onto the hot spare, The hot spare becomes a member of the virtual disk and is no longer assigned as a hot spare. In this situation, assigning a new hot spare to maintain data protection in recommended.
Recommended Response Action
No response action is required. Assigning a new dedicated hot spare to the virtual disk is recommended.
Category
Storage (PDR = Physical Disk)
Severity
Severity 3 (Informational)
Trap/EventID
4347
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC              

PDR107

Message
The physical disk drive arg1 is assigned as a global hot-spare.
Arguments
arg1 = physical disk drive name
Detailed Description
The physical disk drive identified in the message is assigned as a global hot-spare.
Recommended Response Action
No response action is required.
Category
Storage (PDR = Physical Disk)
Severity
Severity 3 (Informational)
Trap/EventID
4347
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC              

PDR108

Message
The physical disk drive arg1 is unassigned as a global hot spare.
Arguments
arg1 = physical disk drive name
Detailed Description
The physical disk identified in the message that had been assigned as a hot spare has been unassigned and is no longer functioning as a hot spare. The physical disk was unassigned by a user or automatically by the storage management software. When one of the disks in a virtual disk fails, data is rebuilt onto the hot spare, The hot spare becomes a member of the virtual disk and is no longer assigned as a hot spare. In this situation, assigning a new hot spare to maintain data protection in recommended.
Recommended Response Action
No response action is required. Assigning a new global hot spare is recommended.
Category
Storage (PDR = Physical Disk)
Severity
Severity 3 (Informational)
Trap/EventID
4347
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC              

PDR11

Message
arg1 rebuild was cancelled.
Arguments
arg1 = physical disk
Detailed Description
A user has cancelled the rebuild operation.
Recommended Response Action
Restart the rebuild operation.
Category
Storage (PDR = Physical Disk)
Severity
Severity 3 (Informational)
Trap/EventID
4347
OMSA Event ID
2074
OMSA Trap ID
90100
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*          

PDR110

Message
The arg1 reliability has degraded.
Arguments
arg1 = PCIe solid state device name
Detailed Description
The reliability of the PCIe solid state device identified in the message degraded. Data loss is possible.
Recommended Response Action
Back up the data on the device, and contact your service provider for further instructions.
Category
Storage (PDR = Physical Disk)
Severity
Severity 1 (Critical)
OMSA Event ID
2442
OMSA Trap ID
90400
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC          
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

PDR1100

Message
Drive arg1 is installed.
Arguments
arg1 = number
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health (PDR = Physical Disk)
Severity
Severity 3 (Informational)
Trap/EventID
2299
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC              

PDR1101

Message
Fault detected on drive arg1 .
Arguments
arg1 = number
Detailed Description
The controller detected a failure on the disk and has taken the disk offline.
Recommended Response Action
Remove and reseat the failed disk. If the problem persists, contact technical support. Refer to the product documentation to choose a convenient contact method.
Category
System Health (PDR = Physical Disk)
Severity
Severity 1 (Critical)
Trap/EventID
2297
LCD Message
Fault detected on drive <number>. Check drive.
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC              

PDR1102

Message
A predictive failure detected on drive arg1 .
Arguments
arg1 = number
Detailed Description
The controller received a SMART error from the drive. The drive is operational but needs replacement.
Recommended Response Action
The drive will need replacement at the next service window.
Category
System Health (PDR = Physical Disk)
Severity
Severity 2 (Warning)
Trap/EventID
2298
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC              

PDR1103

Message
Drive arg1 is the hot-spare drive.
Arguments
arg1 = number
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health (PDR = Physical Disk)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

PDR1104

Message
Consistency check is in progress for drive arg1 .
Arguments
arg1 = number
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health (PDR = Physical Disk)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

PDR1105

Message
Drive arg1 is in the critical array.
Arguments
arg1 = number
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health (PDR = Physical Disk)
Severity
Severity 1 (Critical)
LCD Message
Drive <number> is in the critical array. Replace drive.
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

PDR1106

Message
Drive arg1 is in the failed array.
Arguments
arg1 = number
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health (PDR = Physical Disk)
Severity
Severity 1 (Critical)
LCD Message
Drive <number> is in the failed array. Replace drive.
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

PDR1107

Message
Rebuild is in progress for drive arg1 .
Arguments
arg1 = number
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health (PDR = Physical Disk)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

PDR1108

Message
Rebuild was aborted for drive arg1 .
Arguments
arg1 = number
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health (PDR = Physical Disk)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

PDR111

Message
The volatile memory backup device on arg1 is no longer functional.
Arguments
arg1 = PCIe solid state device name
Detailed Description
The volatile memory backup device on the PCIe solid state device identified in the message is no longer functional. Data loss is possible.
Recommended Response Action
Back up the data on the device, and contact your service provider for further instructions.
Category
Storage (PDR = Physical Disk)
Severity
Severity 1 (Critical)
OMSA Event ID
2443
OMSA Trap ID
90400
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC          
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

PDR1116

Message
Drive arg1 is removed.
Arguments
arg1 = number
Detailed Description
The controller detected a drive removal
Recommended Response Action
If unintended, verify drive installation. Remove and reseat the indicated disk. If the problem persists, contact technical support. Refer to the product documentation to choose a convenient contact method.
Category
System Health (PDR = Physical Disk)
Severity
Severity 1 (Critical)
Trap/EventID
2297
LCD Message
Drive <number> is removed. Check drive
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC              

PDR1117

Message
Drive arg1 is operating normally.
Arguments
arg1 = number
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health (PDR = Physical Disk)
Severity
Severity 3 (Informational)
Trap/EventID
2299
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC              

PDR1119

Message
Drive arg1 is no longer the hot-spare drive.
Arguments
arg1 = number
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health (PDR = Physical Disk)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

PDR112

Message
The arg1 has reached arg2 of warranted device wear-out limit.
Arguments
arg1 = PCIe solid state device name, arg2 = percent
Detailed Description
The PCIe solid state device identified in the message is approaching the warranted wear-out limit.
Recommended Response Action
No response action is required.
Category
Storage (PDR = Physical Disk)
Severity
Severity 2 (Warning)
Trap/EventID
4346
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC              

PDR1120

Message
Consistency check for drive arg1 completed.
Arguments
arg1 = number
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health (PDR = Physical Disk)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

PDR1121

Message
Drive arg1 is no longer in the critical array.
Arguments
arg1 = number
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health (PDR = Physical Disk)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

PDR1122

Message
Drive arg1 is no longer in the failed array.
Arguments
arg1 = number
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health (PDR = Physical Disk)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

PDR1123

Message
Rebuild completed for drive arg1 .
Arguments
arg1 = number
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health (PDR = Physical Disk)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

PDR113

Message
The arg1 has reached or exceeded its warranted wear-out limit.
Arguments
arg1 = PCIe solid state device name
Detailed Description
The PCIe solid state device identified in the message has either reached or exceeded the warranted wear-out limit.
Recommended Response Action
Back up the data on the device, and contact your service provider for further instructions.
Category
Storage (PDR = Physical Disk)
Severity
Severity 2 (Warning)
Trap/EventID
4346
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC              

PDR114

Message
The arg1 is approaching read-only mode.
Arguments
arg1 = PCIe solid state device name
Detailed Description
The PCIe solid state device identified in the message is between 90% and 100% of reaching read-only mode.
Recommended Response Action
No response action is required.
Category
Storage (PDR = Physical Disk)
Severity
Severity 2 (Warning)
OMSA Event ID
2440
OMSA Trap ID
90400
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC        
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

PDR115

Message
The arg1 is in read-only mode.
Arguments
arg1 = PCIe solid state device name
Detailed Description
The PCIe solid state device identified in the message is in read-only mode.
Recommended Response Action
Back up the data on the device, and contact your service provider for further instructions.
Category
Storage (PDR = Physical Disk)
Severity
Severity 1 (Critical)
Trap/EventID
4345
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC              

PDR116

Message
Predictive failure reported for arg1
Arguments
arg1 = PCIe solid state device name
Detailed Description
The PCIe Solid-State Drive is predicted to fail. Many physical disks contain Self Monitoring Analysis and Reporting Technology (SMART). When enabled, SMART monitors the disk health based on indications such as the number of write operations that were performed on the disk.
Recommended Response Action
Back up the data on the device, and contact your service provider for further instructions.
Category
Storage (PDR = Physical Disk)
Severity
Severity 2 (Warning)
Trap/EventID
4346
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC              

PDR117

Message
The arg1 has turned off because the critical temperature threshold is exceeded.
Arguments
arg1 = PCIe solid state device name
Detailed Description
The PCIe solid state device identified in the message has turned off because the critical temperature threshold of the device was exceeded.
Recommended Response Action
Contact your service provider for further instructions.
Category
Storage (PDR = Physical Disk)
Severity
Severity 1 (Critical)
Trap/EventID
4345
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC      
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC              

PDR12

Message
arg1 initialization has failed.
Arguments
arg1 = PD Name
Detailed Description
The physical disk has failed or is corrupt.
Recommended Response Action
Replace the failed or corrupt disk. Identify a disk that has failed by locating the disk that has a red "X" for its status. Restart the initialization.
Category
Storage (PDR = Physical Disk)
Severity
Severity 1 (Critical)
Trap/EventID
4345
OMSA Event ID
2080
OMSA Trap ID
90400
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*          

PDR13

Message
arg1 rebuild has failed.
Arguments
arg1 = physical disk
Detailed Description
A physical disk included in the virtual disk has failed or is corrupted. In addition, you may have cancelled the rebuild.
Recommended Response Action
Replace the failed or corrupt disk, and then start the rebuild operation.
Category
Storage (PDR = Physical Disk)
Severity
Severity 1 (Critical)
Trap/EventID
4345
OMSA Event ID
2083
OMSA Trap ID
90400
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*          

PDR14

Message
arg1 initialization is complete.
Arguments
arg1 = PD Name
Detailed Description
This alert is provided for informational purposes.
Recommended Response Action
No response action is required.
Category
Storage (PDR = Physical Disk)
Severity
Severity 3 (Informational)
Trap/EventID
4347
OMSA Event ID
2089
OMSA Trap ID
90100
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*          

PDR15

Message
arg1 rebuild is complete.
Arguments
arg1 = physical disk
Detailed Description
This message is generated after a rebuild completes on a physical disk.
Recommended Response Action
No response action is required.
Category
Storage (PDR = Physical Disk)
Severity
Severity 3 (Informational)
Trap/EventID
4347
OMSA Event ID
2092
OMSA Trap ID
90100
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*          

PDR16

Message
Predictive failure reported for arg1 .
Arguments
arg1 = physical disk
Detailed Description
The physical disk is predicted to fail. Many physical disks contain Self Monitoring Analysis and Reporting Technology (SMART). When enabled, SMART monitors the disk health based on indications such as the number of write operations that were performed on the disk.
Recommended Response Action
Replace the physical disk. Even though the disk may not have failed yet, it is strongly recommended that the disk be replaced. Review other messages for additional information.
Category
Storage (PDR = Physical Disk)
Severity
Severity 2 (Warning)
Trap/EventID
4346
OMSA Event ID
2094
OMSA Trap ID
90300
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*          

PDR17

Message
Global hot spare assigned to arg1 .
Arguments
arg1 = PD Name
Detailed Description
A user has have assigned a physical disk as a global hot spare. This alert is provided for informational purposes.
Recommended Response Action
No response action is required.
Category
Storage (PDR = Physical Disk)
Severity
Severity 3 (Informational)
Trap/EventID
4347
OMSA Event ID
2098
OMSA Trap ID
90100
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*          

PDR18

Message
Global hot spare unassigned from arg1 .
Arguments
arg1 = PD Name
Detailed Description
A physical disk assigned as a hot spare was unassigned and is no longer functioning as a hot spare. The physical disk was unassigned by a user or automatically unassigned by Storage Management. Storage Management unassigns hot spares were used to rebuild data. Once the data is rebuilt onto the hot spare, the hot spare becomes a member of the virtual disk and is no longer assigned as a hot spare. Assign a new hot spare to maintain data protection in this situation.
Recommended Response Action
Although this alert is provided for informational purposes, you may need to assign a new hot spare to the virtual disk. See Protecting Your Virtual Disk with a Hot Spare for more information.
Category
Storage (PDR = Physical Disk)
Severity
Severity 3 (Informational)
Trap/EventID
4347
OMSA Event ID
2099
OMSA Trap ID
90100
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*          

PDR19

Message
SMART FPT exceeded for arg1 .
Arguments
arg1 = PD Name
Detailed Description
A disk on the specified controller has received a SMART alert (predictive failure) indicating that the disk is likely to fail in the near future.
Recommended Response Action
Replace the disk that has received the SMART alert. If the physical disk is a member of a non-redundant virtual disk, then back up the data before replacing the disk. Removing a physical disk that is included in a non-redundant virtual disk causes the virtual disk to fail and may cause data loss.
Category
Storage (PDR = Physical Disk)
Severity
Severity 2 (Warning)
Trap/EventID
4346
OMSA Event ID
2106
OMSA Trap ID
90300
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*          

PDR2

Message
Insufficient space available on arg1 to perform a copyback operation.
Arguments
arg1 = physical disk
Detailed Description
This message is generated if a physical disk does not have enough space to do a copyback operation.
Recommended Response Action
Replace the physical disk with a larger physical disk, and then restart the copyback operation.
Category
Storage (PDR = Physical Disk)
Severity
Severity 2 (Warning)
Trap/EventID
4346
OMSA Event ID
2198
OMSA Trap ID
90300
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*          

PDR20

Message
SMART configuration change for arg1 .
Arguments
arg1 = PD Name
Detailed Description
A disk has received a SMART alert (predictive failure) after a configuration change. The disk is likely to fail in the near future.
Recommended Response Action
Replace the disk that has received the SMART alert. If the physical disk is a member of a non-redundant virtual disk, then back up the data before replacing the disk. Removing a physical disk that is included in a non-redundant virtual disk will cause the virtual disk to fail and may cause data loss.
Category
Storage (PDR = Physical Disk)
Severity
Severity 1 (Critical)
Trap/EventID
4345
OMSA Event ID
2107
OMSA Trap ID
90400
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*          

PDR206

Message
arg1 is a solid state drive (SSD) that is not supported by the controller.
Arguments
arg1 = physical disk name
Detailed Description
The storage controller does not support the attached SSD devices.
Recommended Response Action
Remove SSD devices not supported by the controller, and retry the operation.
Category
Storage (PDR = Physical Disk)
Severity
Severity 2 (Warning)
OMSA Event ID
2382
OMSA Trap ID
90300
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC        
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC            
CMC              

PDR207

Message
Unable to assign arg1 as a dedicated hot spare.
Arguments
arg1 = physical disk name
Detailed Description
Unable to assign the physical disk as a dedicated hot spare because the selected disk size does not meet the size requirements of the target Virtual Disk.
Recommended Response Action
Select a physical disk that matches the size required for the disks used in the target Virtual Disk, and retry the operation.
Category
Storage (PDR = Physical Disk)
Severity
Severity 3 (Informational)
OMSA Event ID
2386
OMSA Trap ID
90100
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC        
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC            
CMC              

PDR208

Message
Instant Secure Erase operation successfully completed on arg1 .
Arguments
arg1 = physical disk name
Detailed Description
The secure erase operation successfully completed on the Self-Encrypting Drive (SED) identified in the message.
Recommended Response Action
No response action is required.
Category
Storage (PDR = Physical Disk)
Severity
Severity 3 (Informational)
OMSA Event ID
2390
OMSA Trap ID
90100
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC        
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC            
CMC              

PDR209

Message
The power status of arg1 is changed from arg2 to arg3 .
Arguments
arg1 = physical disk name, arg2 = previous power status, arg3 = current power status
Detailed Description
The Manage Physical Disk Power feature is enabled for physical drives and the power status of the drives changed.
Recommended Response Action
No response action is required.
Category
Storage (PDR = Physical Disk)
Severity
Severity 3 (Informational)
OMSA Event ID
2399
OMSA Trap ID
90100
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC        
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC            
CMC              

PDR21

Message
SMART warning for arg1
Arguments
arg1 = PD Name
Detailed Description
A disk has received a SMART alert (predictive failure). The disk is likely to fail in the near future.
Recommended Response Action
Replace the disk that has received the SMART alert. If the physical disk is a member of a non-redundant virtual disk, then back up the data before replacing the disk. Removing a physical disk that is included in a non-redundant virtual disk will cause the virtual disk to fail and may cause data loss.
Category
Storage (PDR = Physical Disk)
Severity
Severity 2 (Warning)
Trap/EventID
4346
OMSA Event ID
2108
OMSA Trap ID
90300
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*          

PDR210

Message
Successfully updated configuration data on the arg1 .
Arguments
arg1 = physical disk name
Detailed Description
This event is generated while initializing the drives during reboot. The controller updated the configuration data on the physical disks identified in the message. The drive configuration was updated because the following conditions were present: 1) The spundown drives were used for configuration. Spundown drives are drives that are temporarily powered off because power saving option is enabled. 2) The storage controller was not able to update the Configuration On Disk (COD) records on the drive while they were spundown.
Recommended Response Action
No response action is required.
Category
Storage (PDR = Physical Disk)
Severity
Severity 3 (Informational)
OMSA Event ID
2400
OMSA Trap ID
90100
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC        
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC            
CMC              

PDR211

Message
arg1 has encountered storage medium error.
Arguments
arg1 = physical disk name
Detailed Description
Storage medium error was detected on the disk identified in the message.
Recommended Response Action
No response action is required.
Category
Storage (PDR = Physical Disk)
Severity
Severity 2 (Warning)
OMSA Event ID
2416
OMSA Trap ID
90300
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC        
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC            
CMC              

PDR212

Message
The state of arg1 changed from Ready to Non-RAID.
Arguments
arg1 = physical disk name
Detailed Description
The physical disk state has changed from Ready state to Non-RAID state.
Recommended Response Action
No response action is required.
Category
Storage (PDR = Physical Disk)
Severity
Severity 3 (Informational)
OMSA Event ID
2425
OMSA Trap ID
90100
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC        
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC            
CMC              

PDR213

Message
The state of arg1 changed from Non-RAID to Ready.
Arguments
arg1 = physical disk name
Detailed Description
The physical disk state has changed from Non-RAID state to Ready state.
Recommended Response Action
No response action is required.
Category
Storage (PDR = Physical Disk)
Severity
Severity 3 (Informational)
OMSA Event ID
2426
OMSA Trap ID
90100
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC        
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC            
CMC              

PDR214

Message
The arg1 is not supported because it is not supplied by an authroized hardware provider.
Arguments
arg1 = physical disk name
Detailed Description
The physical disk identified in the message is not compliant with the standards set by the hardware provider and is not supported.
Recommended Response Action
Replace the physical disk with a supported physical disk that is provided by an authorized hardware provider.
Category
Storage (PDR = Physical Disk)
Severity
Severity 2 (Warning)
OMSA Event ID
2359
OMSA Trap ID
90300
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC        
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC            
CMC              

PDR215

Message
Copyback task to arg1 has failed.
Arguments
arg1 = physical disk name
Detailed Description
The Replace Member Disk operation did not complete succesfully because of internal errors. The error may be due to problems with the source or target physical disks or the controller may be out of resources.
Recommended Response Action
Retry the Replace Member Disk operation with a different target physical disk. If the problem persists, check the condition of the target physical disk and replace if necessary, then rety the operation.
Category
Storage (PDR = Physical Disk)
Severity
Severity 1 (Critical)
OMSA Event ID
2183
OMSA Trap ID
90400
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC        
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC            
CMC              

PDR22

Message
SMART warning temperature for arg1
Arguments
arg1 = PD Name
Detailed Description
A disk has reached an unacceptable temperature and received a SMART alert (predictive failure). The disk is likely to fail in the near future.
Recommended Response Action
Do the following: 1) Determine why the physical disk reached an unacceptable temperature. For example, a fan failure, incorrect thermostat settings, or the room temperature may be too hot or cold. 2) Verify that the fans in the server or enclosure are working. 3) If the physical disk is in an enclosure, check the thermostat settings and examine whether the enclosure is located near a heat source. Verify the enclosure has enough ventilation and that the room temperature is not too hot. Refer to the enclosure documentation for more diagnostic information. 4) If you cannot identify why the disk has reached an unacceptable temperature, then replace the disk. If the physical disk is a member of a non-redundant virtual disk, then back up the data before replacing the disk. Removing a physical disk that is included in a non-redundant virtual disk causes the virtual disk to fail and may cause data loss.
Category
Storage (PDR = Physical Disk)
Severity
Severity 2 (Warning)
Trap/EventID
4346
OMSA Event ID
2109
OMSA Trap ID
90300
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*          

PDR23

Message
SMART warning degraded for arg1
Arguments
arg1 = PD Name
Detailed Description
A disk is degraded and has received a SMART alert (predictive failure). The disk is likely to fail in the near future.
Recommended Response Action
Replace the disk that has received the SMART alert. If the physical disk is a member of a non-redundant virtual disk, then back up the data before replacing the disk. Removing a physical disk that is included in a non-redundant virtual disk will cause the virtual disk to fail and may cause data loss.
Category
Storage (PDR = Physical Disk)
Severity
Severity 2 (Warning)
Trap/EventID
4346
OMSA Event ID
2110
OMSA Trap ID
90300
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*          

PDR24

Message
Failure prediction threshold exceeded on arg1 due to test. No action needed.
Arguments
arg1 = PD Name
Detailed Description
A disk has received a SMART alert (predictive failure) due to test conditions.
Recommended Response Action
No response action is required.
Category
Storage (PDR = Physical Disk)
Severity
Severity 2 (Warning)
Trap/EventID
4346
OMSA Event ID
2111
OMSA Trap ID
90300
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*          

PDR25

Message
arg1 dead segments are removed.
Arguments
arg1 = PD Name
Detailed Description
Portions of the physical disk that were formerly inaccessible have been recovered. This alert is provided for informational purposes.
Recommended Response Action
No response action is required.
Category
Storage (PDR = Physical Disk)
Severity
Severity 3 (Informational)
Trap/EventID
4347
OMSA Event ID
2141
OMSA Trap ID
90100
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*          

PDR26

Message
arg1 is online.
Arguments
arg1 = physical disk
Detailed Description
A drive has entered the online state. This may be because the system just started or could be because a problem with the drive has been corrected.
Recommended Response Action
No response action is required.
Category
Storage (PDR = Physical Disk)
Severity
Severity 3 (Informational)
Trap/EventID
4347
OMSA Event ID
2158
OMSA Trap ID
90100
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*          

PDR27

Message
Dedicated hot spare assigned to arg1 .
Arguments
arg1 = PD Name
Detailed Description
A user assigned a physical disk as a dedicated hot spare to a virtual disk. See Protecting Your Virtual Disk with a Hot Spare for more information. This alert is provided for informational purposes.
Recommended Response Action
No response action is required.
Category
Storage (PDR = Physical Disk)
Severity
Severity 3 (Informational)
Trap/EventID
4347
OMSA Event ID
2160
OMSA Trap ID
90100
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*          

PDR28

Message
Dedicated hot spare unassigned from arg1 .
Arguments
arg1 = PD Name
Detailed Description
A physical disk that was assigned as a hot spare has been unassigned and is no longer functioning as a hot spare. The physical disk was unassigned by a user or automatically unassigned by Storage Management. Storage Management unassigns hot spares that have been used to rebuild data. Once data is rebuilt onto the hot spare, the hot spare becomes a member of the virtual disk and is no longer assigned as a hot spare. Assign a new hot spare to maintain data protection in this situation.
Recommended Response Action
Although this alert is provided for informational purposes, you may need to assign a new hot spare to the virtual disk. Refer to product documentation and see the section Protecting Your Virtual Disk with a Hot Spare for more information.
Category
Storage (PDR = Physical Disk)
Severity
Severity 3 (Informational)
Trap/EventID
4347
OMSA Event ID
2161
OMSA Trap ID
90100
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*          

PDR29

Message
Rebuild on arg1 completed with error(s).
Arguments
arg1 = PD Name
Detailed Description
See A Rebuild Completes with Errors for more information.
Recommended Response Action
See A Rebuild Completes with Errors for more information.
Category
Storage (PDR = Physical Disk)
Severity
Severity 1 (Critical)
Trap/EventID
4345
OMSA Event ID
2163
OMSA Trap ID
90400
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*          

PDR3

Message
arg1 is not functioning correctly.
Arguments
arg1 = PD Name
Detailed Description
The RAID Controller may not be able to read/write data to the physical disk drive indicated in the message. This may be due to a failure with the physical disk drive or because the physical disk drive was removed from the system.
Recommended Response Action
Remove and re-insert the physical disk drive identified in the message and make sure the physical disk drive is inserted properly. If the issue persists, replace the physical disk drive.
Category
Storage (PDR = Physical Disk)
Severity
Severity 1 (Critical)
Trap/EventID
4345
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*          

PDR30

Message
A global hot spare failed. arg1
Arguments
arg1 = PD Name
Detailed Description
The controller cannot to communicate with a disk that is assigned as a global hot spare. The disk either failed or was removed. There may also be a bad or loose cable.
Recommended Response Action
Verify that the disk is healthy and installed. Check the cables. Refer to the product documentation and see the Cables Attached Correctly section for more information on checking the cables. If necessary, replace the disk and reassign the global hot spare.
Category
Storage (PDR = Physical Disk)
Severity
Severity 2 (Warning)
Trap/EventID
4346
OMSA Event ID
2201
OMSA Trap ID
90300
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*          

PDR31

Message
A global hot spare has been removed. arg1
Arguments
arg1 = PD Name
Detailed Description
The controller cannot to communicate with a disk that is assigned as a global hot spare. The disk either failed or was removed. There may also be a bad or loose cable.
Recommended Response Action
Verify that the disk is healthy and installed. Check the cables. Refer to the product documentation and see the Cables Attached Correctly section for more information on checking the cables. If necessary, replace the disk and reassign the global hot spare.
Category
Storage (PDR = Physical Disk)
Severity
Severity 3 (Informational)
Trap/EventID
4347
OMSA Event ID
2202
OMSA Trap ID
90100
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*          

PDR32

Message
A dedicated hot spare failed. arg1
Arguments
arg1 = PD Name
Detailed Description
The controller cannot to communicate with a disk that is assigned as a global hot spare. The disk either failed or was removed. There may also be a bad or loose cable.
Recommended Response Action
Verify that the disk is healthy and installed. Check the cables. Refer to the product documentation and see the Cables Attached Correctly section for more information on checking the cables. If necessary, replace the disk and reassign the global hot spare.
Category
Storage (PDR = Physical Disk)
Severity
Severity 2 (Warning)
Trap/EventID
4346
OMSA Event ID
2203
OMSA Trap ID
90300
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*          

PDR33

Message
A dedicated hot spare has been removed. arg1
Arguments
arg1 = PD Name
Detailed Description
The controller cannot to communicate with a disk that is assigned as a global hot spare. The disk either failed or was removed. There may also be a bad or loose cable.
Recommended Response Action
Verify that the disk is healthy and installed. Check the cables. Refer to the product documentation and see the Cables Attached Correctly section for more information on checking the cables. If necessary, replace the disk and reassign the global hot spare.
Category
Storage (PDR = Physical Disk)
Severity
Severity 3 (Informational)
Trap/EventID
4347
OMSA Event ID
2204
OMSA Trap ID
90100
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*          

PDR34

Message
A dedicated hot spare has been automatically unassigned. arg1
Arguments
arg1 = PD Name
Detailed Description
The hot spare is no longer required because the virtual disk it was assigned to has been deleted.
Recommended Response Action
No response action is required.
Category
Storage (PDR = Physical Disk)
Severity
Severity 3 (Informational)
Trap/EventID
4347
OMSA Event ID
2205
OMSA Trap ID
90100
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*          

PDR35

Message
The only hot spare available is a SATA disk arg1 .
Arguments
arg1 = PD Name
Detailed Description
The only physical disk available to be assigned as a hot spare is using SATA technology. The physical disks in the virtual disk are using SAS technology. Because of this difference in technology, the hot spare cannot rebuild data if one of the physical disks in the virtual disk fails.
Recommended Response Action
Add a SAS disk that is large enough to be used as the hot spare and assign the new disk as a hot spare.
Category
Storage (PDR = Physical Disk)
Severity
Severity 2 (Warning)
Trap/EventID
4346
OMSA Event ID
2206
OMSA Trap ID
90300
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*          

PDR36

Message
The only hot spare available is a SAS disk arg1 .
Arguments
arg1 = PD Name
Detailed Description
The only physical disk available to be assigned as a hot spare is using SAS technology. The physical disks in the virtual disk are using SATA technology. Because of this difference in technology, the hot spare cannot rebuild data if one of the physical disks in the virtual disk fails.
Recommended Response Action
Add a SATA disk that is large enough to be used as the hot spare and assign the new disk as a hot spare.
Category
Storage (PDR = Physical Disk)
Severity
Severity 2 (Warning)
Trap/EventID
4346
OMSA Event ID
2207
OMSA Trap ID
90300
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*          

PDR37

Message
The arg1 is not supported.
Arguments
arg1 = physical device
Detailed Description
The physical device may not have a supported version of the firmware or the physical device may not be supported.
Recommended Response Action
If the physical device is supported, then update the firmware to a supported version. If the physical device is not supported, then replace the physical device with one that is supported.
Category
Storage (PDR = Physical Disk)
Severity
Severity 2 (Warning)
Trap/EventID
4346
OMSA Event ID
2211
OMSA Trap ID
90300
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*          

PDR38

Message
A clear operation started on arg1 .
Arguments
arg1 = physical disk
Detailed Description
A user has initiated a clear operation on a physical disk.
Recommended Response Action
No response action is required.
Category
Storage (PDR = Physical Disk)
Severity
Severity 3 (Informational)
Trap/EventID
4347
OMSA Event ID
2249
OMSA Trap ID
90100
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*          

PDR39

Message
A blink operation has initiated on arg1 .
Arguments
arg1 = physical disk
Detailed Description
This alert is provided for informational purposes.
Recommended Response Action
No response action is required.
Category
Storage (PDR = Physical Disk)
Severity
Severity 3 (Informational)
Trap/EventID
4347
OMSA Event ID
2251;2437
OMSA Trap ID
90100
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*          

PDR4

Message
arg1 returned to a ready state.
Arguments
arg1 = physical disk
Detailed Description
A physical drive that was previously in an error state has returned to a ready state.
Recommended Response Action
No response action is required.
Category
Storage (PDR = Physical Disk)
Severity
Severity 3 (Informational)
Trap/EventID
4347
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*          

PDR40

Message
The blink operation has ceased on arg1 .
Arguments
arg1 = physical disk
Detailed Description
This alert is provided for informational purposes.
Recommended Response Action
No response action is required.
Category
Storage (PDR = Physical Disk)
Severity
Severity 3 (Informational)
Trap/EventID
4347
OMSA Event ID
2252;2438
OMSA Trap ID
90100
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*          

PDR41

Message
The clear operation on arg1 was cancelled.
Arguments
arg1 = physical disk
Detailed Description
The clear command did not complete on the physical disk. This means that some data was not cleared and may be recoverable.
Recommended Response Action
No response action is required.
Category
Storage (PDR = Physical Disk)
Severity
Severity 3 (Informational)
Trap/EventID
4347
OMSA Event ID
2254
OMSA Trap ID
90100
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*          

PDR42

Message
arg1 has been started.
Arguments
arg1 = physical disk
Detailed Description
This alert is provided for informational purposes.
Recommended Response Action
No response action is required.
Category
Storage (PDR = Physical Disk)
Severity
Severity 3 (Informational)
Trap/EventID
4347
OMSA Event ID
2255
OMSA Trap ID
90100
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*          

PDR43

Message
The clear operation on arg1 has completed.
Arguments
arg1 = physical disk
Detailed Description
This message is generated after a clear operation completes on a physical disk.
Recommended Response Action
No response action is required.
Category
Storage (PDR = Physical Disk)
Severity
Severity 3 (Informational)
Trap/EventID
4347
OMSA Event ID
2269
OMSA Trap ID
90100
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*          

PDR44

Message
The clear operation on arg1 failed.
Arguments
arg1 = physical disk
Detailed Description
A Clear task was being performed on a physical disk but the task was interrupted and did not complete successfully. The controller may have lost communication with the disk, the disk was removed, or the cables may be loose or defective.
Recommended Response Action
Verify that the disk is present and not in a Failed state. Make sure the cables are attached securely. See the storage hardware documentation for more information on checking the cables. Restart the Clear task.
Category
Storage (PDR = Physical Disk)
Severity
Severity 1 (Critical)
Trap/EventID
4345
OMSA Event ID
2270
OMSA Trap ID
90400
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*          

PDR46

Message
Patrol Read found an uncorrectable media error on arg1 .
Arguments
arg1 = physical disk
Detailed Description
The Patrol Read task has encountered an error that cannot be corrected. There may be a bad disk block that cannot be remapped.
Recommended Response Action
Backup your data from the disk. Start disk initialization and wait for it to complete, then restore the data from the backup to the disk.
Category
Storage (PDR = Physical Disk)
Severity
Severity 1 (Critical)
Trap/EventID
4345
OMSA Event ID
2272
OMSA Trap ID
90400
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*          

PDR47

Message
A block on arg1 was punctured by the controller.
Arguments
arg1 = physical disk
Detailed Description
The controller encountered an unrecoverable medium error when attempting to read a block on the physical disk and marked that block as invalid. If the controller encountered the unrecoverable medium error on a source physical disk during a rebuild or reconfigure operation, it punctures the corresponding block on the target physical disk. The invalid block clears on a write operation.
Recommended Response Action
Back up the data from the disk. Start disk initialization and wait for it to complete, and then restore the data from a backup copy.
Category
Storage (PDR = Physical Disk)
Severity
Severity 1 (Critical)
Trap/EventID
4345
OMSA Event ID
2273
OMSA Trap ID
90400
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*          

PDR48

Message
The arg1 rebuild has resumed.
Arguments
arg1 = physical disk
Detailed Description
This message is generated after rebuild resumes on a physical disk.
Recommended Response Action
No response action is required.
Category
Storage (PDR = Physical Disk)
Severity
Severity 3 (Informational)
Trap/EventID
4347
OMSA Event ID
2274
OMSA Trap ID
90100
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*          

PDR49

Message
The dedicated hot spare arg1 is too small.
Arguments
arg1 = PD Name
Detailed Description
The dedicated hot spare is not large enough to protect all virtual disks that reside on the disk group.
Recommended Response Action
Assign a larger disk as the dedicated hot spare.
Category
Storage (PDR = Physical Disk)
Severity
Severity 2 (Warning)
Trap/EventID
4346
OMSA Event ID
2276
OMSA Trap ID
90300
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*          

PDR5

Message
arg1 is removed.
Arguments
arg1 = PD Name
Detailed Description
A physical disk has been removed from the disk group. This alert can also be caused by loose or defective cables or by problems with the enclosure.
Recommended Response Action
Do one of the following: 1) If a physical disk was removed from the disk group, either replace the disk or restore the original disk. Identify the disk that was removed by locating the disk that has a red "X" for its status. 2) Perform a rescan after replacing or restoring the disk. 3) If a disk was not removed from the disk group, then check for cable problems. Refer to product documentation for more information on checking the cables. 4) Make sure that the enclosure is powered on. 5) If the problem persists, check the enclosure documentation for further diagnostic information.
Category
Storage (PDR = Physical Disk)
Severity
Severity 2 (Warning)
Trap/EventID
4346
OMSA Event ID
2049
OMSA Trap ID
90300
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*          

PDR50

Message
Insufficient space on the global hot spare arg1 .
Arguments
arg1 = PD Name
Detailed Description
The global hot spare is not large enough to protect all virtual disks that reside on the controller.
Recommended Response Action
Assign a larger disk as the global hot spare.
Category
Storage (PDR = Physical Disk)
Severity
Severity 2 (Warning)
Trap/EventID
4346
OMSA Event ID
2277
OMSA Trap ID
90300
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*          

PDR51

Message
Hot spare arg1 SMART polling has failed. arg2
Arguments
arg1 = physical disk, arg2 = args
Detailed Description
The controller firmware attempted to do SMART polling on the hot spare but could not complete the SMART polling. The controller may have lost communication with the hot spare.
Recommended Response Action
Verify the health of the disk assigned as a hot spare. Replace the disk and reassign the hot spare. Make sure the cables are attached securely. See the storage hardware documentation for more information on checking the cables.
Category
Storage (PDR = Physical Disk)
Severity
Severity 1 (Critical)
Trap/EventID
4345
OMSA Event ID
2282
OMSA Trap ID
90400
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*          

PDR52

Message
A redundant path is broken.
Detailed Description
The controller has two connectors that are connected to the same enclosure. The communication path on one connector has lost connection with the enclosure. The communication path on the other connector is reporting this loss.
Recommended Response Action
Make sure the cables are attached securely. See the Cables Attached Correctly section for more information on checking the cables. Make sure both Enclosure Management Modules (EMMs) are healthy.
Category
Storage (PDR = Physical Disk)
Severity
Severity 2 (Warning)
Trap/EventID
4346
OMSA Event ID
2283
OMSA Trap ID
90300
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC      
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*          

PDR53

Message
A redundant path has been restored for arg1 .
Arguments
arg1 = PD Name
Detailed Description
This alert is provided for informational purposes.
Recommended Response Action
No response action is required.
Category
Storage (PDR = Physical Disk)
Severity
Severity 3 (Informational)
Trap/EventID
4347
OMSA Event ID
2284
OMSA Trap ID
90100
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC      
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*          

PDR54

Message
A disk media error on arg1 was corrected during recovery.
Arguments
arg1 = physical disk
Detailed Description
This message is generated after a disk media error is corrected on a physical disk.
Recommended Response Action
No response action is required.
Category
Storage (PDR = Physical Disk)
Severity
Severity 3 (Informational)
Trap/EventID
4347
OMSA Event ID
2285
OMSA Trap ID
90100
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*          

PDR55

Message
Insufficient space available on the arg1 to perform a rebuild.
Arguments
arg1 = physical disk
Detailed Description
The physical disk inserted is too small for the rebuild to occur.
Recommended Response Action
Replace the physical disk with one of correct protocol (SAS, SATA) with at least the required size. Force rebuild if it does not start automatically.
Category
Storage (PDR = Physical Disk)
Severity
Severity 2 (Warning)
Trap/EventID
4346
OMSA Event ID
2305
OMSA Trap ID
90300
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*          

PDR56

Message
Bad block table on arg1 is 80% full.
Arguments
arg1 = physical disk
Detailed Description
The bad block table is the table used for remapping bad disk blocks. This table fills as bad disk blocks are remapped. When the table is full, bad disk blocks are no longer remapped, which means that disk errors are no longer corrected. At this point, data loss can occur. The bad block table is now 80 percent full.
Recommended Response Action
Replace the disk generating this message.
Category
Storage (PDR = Physical Disk)
Severity
Severity 2 (Warning)
Trap/EventID
4346
OMSA Event ID
2306
OMSA Trap ID
90300
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*          

PDR57

Message
Bad block table on arg1 is full. Unable to log block arg2 .
Arguments
arg1 = physical disk, arg2 = logical block address
Detailed Description
The bad block table is the table used for remapping bad disk blocks. This table fills as bad disk blocks are remapped. When the table is full, bad disk blocks are no longer remapped, which means that disk errors are no longer corrected. At this point, data loss can occur.
Recommended Response Action
Replace the disk generating this message and restore from a backup copy. You may have lost data.
Category
Storage (PDR = Physical Disk)
Severity
Severity 1 (Critical)
Trap/EventID
4345
OMSA Event ID
2307
OMSA Trap ID
90400
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*          

PDR58

Message
arg1 is incompatible.
Arguments
arg1 = PD Name
Detailed Description
A user attempted to replace a disk with another disk that is using an incompatible technology. For example, replaced one side of a mirror with a SAS disk when the other side of the mirror is using SATA technology.
Recommended Response Action
Refer to the hardware documentation for information on replacing disks.
Category
Storage (PDR = Physical Disk)
Severity
Severity 2 (Warning)
Trap/EventID
4346
OMSA Event ID
2309
OMSA Trap ID
90300
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*          

PDR59

Message
A bad disk block was reassigned on arg1 .
Arguments
arg1 = physical disk
Detailed Description
The disk has a bad block. Data was remapped to another disk block. No data loss has occurred.
Recommended Response Action
Monitor the disk for other messages or indications of poor health.
Category
Storage (PDR = Physical Disk)
Severity
Severity 3 (Informational)
Trap/EventID
4347
OMSA Event ID
2331
OMSA Trap ID
90100
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*          

PDR6

Message
arg1 is offline.
Arguments
arg1 = physical disk
Detailed Description
A physical disk in the virtual disk is offline. This may have been user initiated.
Recommended Response Action
Force the physical disk online or assign a hot spare to the virtual disk.
Category
Storage (PDR = Physical Disk)
Severity
Severity 2 (Warning)
Trap/EventID
4346
OMSA Event ID
2050
OMSA Trap ID
90300
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*          

PDR60

Message
Error occurred on arg1 : arg2 .
Arguments
arg1 = physical disk, arg2 = error code
Detailed Description
The reason for the error can vary depending on the situation. The firmware error code is indicated in the message.
Recommended Response Action
Verify the health of attached devices. Review the Lifecycle log for significant events. Replace faulty hardware, if required. Make sure the cables are attached securely. Refer to the storage hardware documentation for more information on checking the cable connections.
Category
Storage (PDR = Physical Disk)
Severity
Severity 2 (Warning)
Trap/EventID
4346
OMSA Event ID
2346
OMSA Trap ID
90300
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*          

PDR61

Message
The rebuild of arg1 failed due to errors on the source physical disk.
Arguments
arg1 = physical disk
Detailed Description
It is not possible to rebuild data that resides on a defective disk.
Recommended Response Action
Replace the source disk and restore data from backup.
Category
Storage (PDR = Physical Disk)
Severity
Severity 1 (Critical)
Trap/EventID
4345
OMSA Event ID
2347
OMSA Trap ID
90400
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*          

PDR62

Message
The rebuild failed due to errors on the target arg1 .
Arguments
arg1 = physical disk
Detailed Description
It is not possible to rebuild data that resides on a defective disk.
Recommended Response Action
Replace the target disk. If a rebuild does not automatically start after replacing the disk, then initiate the Rebuild task. You may need to assign the new disk as a hot spare to initiate the rebuild.
Category
Storage (PDR = Physical Disk)
Severity
Severity 1 (Critical)
Trap/EventID
4345
OMSA Event ID
2348
OMSA Trap ID
90400
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*          

PDR63

Message
A bad disk block on arg1 cannot be reassigned during a write operation.
Arguments
arg1 = physical disk
Detailed Description
A write operation cannot complete because the disk contains bad disk blocks that could not be reassigned. Data loss may have occurred. Data redundancy may be lost.
Recommended Response Action
Replace the disk.
Category
Storage (PDR = Physical Disk)
Severity
Severity 1 (Critical)
Trap/EventID
4345
OMSA Event ID
2349
OMSA Trap ID
90400
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*          

PDR64

Message
An unrecoverable disk media error occurred on arg1 .
Arguments
arg1 = physical disk
Detailed Description
The rebuild or recovery operation encountered an unrecoverable disk media error.
Recommended Response Action
Replace the disk.
Category
Storage (PDR = Physical Disk)
Severity
Severity 1 (Critical)
Trap/EventID
4345
OMSA Event ID
2350
OMSA Trap ID
90400
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*          

PDR65

Message
arg1 is marked as missing.
Arguments
arg1 = physical disk
Detailed Description
This alert is provided for informational purposes.
Recommended Response Action
No response action is required.
Category
Storage (PDR = Physical Disk)
Severity
Severity 3 (Informational)
Trap/EventID
4347
OMSA Event ID
2351
OMSA Trap ID
90100
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*          

PDR66

Message
arg1 that was marked as missing has been replaced.
Arguments
arg1 = physical disk
Detailed Description
This alert is provided for informational purposes.
Recommended Response Action
No response action is required.
Category
Storage (PDR = Physical Disk)
Severity
Severity 3 (Informational)
Trap/EventID
4347
OMSA Event ID
2352
OMSA Trap ID
90100
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*          

PDR67

Message
An unsupported physical disk drive has been detected.
Detailed Description
The physical disk does not comply with the standards set by service provider and is not supported.
Recommended Response Action
Replace the physical disk with a supported physical disk.
Category
Storage (PDR = Physical Disk)
Severity
Severity 2 (Warning)
Trap/EventID
4346
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*          

PDR68

Message
Dedicated spare arg1 imported as global due to missing disk groups.
Arguments
arg1 = PD Name
Detailed Description
This alert is provided for informational purposes
Recommended Response Action
No response action is required.
Category
Storage (PDR = Physical Disk)
Severity
Severity 3 (Informational)
Trap/EventID
4347
OMSA Event ID
2366
OMSA Trap ID
90100
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*          

PDR69

Message
Rebuild not possible on arg1 .
Arguments
arg1 = physical disk
Detailed Description
Physical disk inserted is of the incorrect protocol. SAS or SATA mixing is not supported in the same virtual disk.
Recommended Response Action
Remove drive, insert correct protocol type, and force a rebuild as imposed for controller and system.
Category
Storage (PDR = Physical Disk)
Severity
Severity 2 (Warning)
Trap/EventID
4346
OMSA Event ID
2367
OMSA Trap ID
90300
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC      
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*          

PDR7

Message
arg1 has degraded.
Arguments
arg1 = physical disk
Detailed Description
A physical disk has reported an error condition and may be degraded. The physical disk may have reported the error condition in response to a check consistency or other operation.
Recommended Response Action
Replace the degraded physical disk. Identify the disk that is degraded by locating the disk that has a red "X" for its status. Perform a rescan after replacing the disk.
Category
Storage (PDR = Physical Disk)
Severity
Severity 2 (Warning)
Trap/EventID
4346
OMSA Event ID
2051
OMSA Trap ID
90300
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*          

PDR70

Message
Copyback started from arg1 to arg2 .
Arguments
arg1 = physical disk, arg2 = physical disk
Detailed Description
A copyback operation began to copy data from one physical disk to another physical disk. This may be due to a user initiated operation or a predictive failure.
Recommended Response Action
No response action is required.
Category
Storage (PDR = Physical Disk)
Severity
Severity 3 (Informational)
Trap/EventID
4347
OMSA Event ID
2060
OMSA Trap ID
120100
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*          

PDR71

Message
Copyback completed from arg1 to arg2 .
Arguments
arg1 = physical disk, arg2 = physical disk
Detailed Description
The copyback operation completed.
Recommended Response Action
No response action is required.
Category
Storage (PDR = Physical Disk)
Severity
Severity 3 (Informational)
Trap/EventID
4347
OMSA Event ID
2075
OMSA Trap ID
120100
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*          

PDR72

Message
Copyback resumed on arg1 from arg2 .
Arguments
arg1 = physical disk, arg2 = physical disk
Detailed Description
This alert is provided for informational purposes
Recommended Response Action
No response action is required.
Category
Storage (PDR = Physical Disk)
Severity
Severity 3 (Informational)
Trap/EventID
4347
OMSA Event ID
2087
OMSA Trap ID
90100
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*          

PDR73

Message
Copyback failed from arg1 to arg2 .
Arguments
arg1 = physical disk, arg2 = physical disk
Detailed Description
The physical disk participating in the copyback operation failed.
Recommended Response Action
Replace the disk and retry the operation.
Category
Storage (PDR = Physical Disk)
Severity
Severity 1 (Critical)
Trap/EventID
4345
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*          

PDR74

Message
Copyback cancelled on arg1 .
Arguments
arg1 = physical disk
Detailed Description
A user cancelled the copyback operation.
Recommended Response Action
No response action is required.
Category
Storage (PDR = Physical Disk)
Severity
Severity 3 (Informational)
Trap/EventID
4347
OMSA Event ID
2184
OMSA Trap ID
90100
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*          

PDR75

Message
Copyback stopped for hot spare arg1 .
Arguments
arg1 = physical disk
Detailed Description
This alert is provided for informational purposes
Recommended Response Action
No response action is required.
Category
Storage (PDR = Physical Disk)
Severity
Severity 2 (Warning)
Trap/EventID
4346
OMSA Event ID
2185
OMSA Trap ID
90300
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*          

PDR76

Message
Copyback not possible as SAS or SATA mixing is not supported.
Detailed Description
Copyback not possible as SAS or SATA mixing is not supported in the same virtual disk. This alert is provided for informational purposes.
Recommended Response Action
No response action is required.
Category
Storage (PDR = Physical Disk)
Severity
Severity 2 (Warning)
Trap/EventID
4346
OMSA Event ID
2200
OMSA Trap ID
90300
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*          

PDR77

Message
arg1 state changed from READY to Non-RAID.
Arguments
arg1 = physical disk
Detailed Description
This alert is provided for informational purposes.
Recommended Response Action
No response action is required.
Category
Storage (PDR = Physical Disk)
Severity
Severity 3 (Informational)
Trap/EventID
4347
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC      
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*          

PDR78

Message
arg1 state changed from Non-RAID to READY.
Arguments
arg1 = physical disk
Detailed Description
This alert is provided for informational purposes.
Recommended Response Action
No response action is required.
Category
Storage (PDR = Physical Disk)
Severity
Severity 3 (Informational)
Trap/EventID
4347
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*          

PDR79

Message
A user terminated Copyback from arg1 to arg2 .
Arguments
arg1 = physical disk, arg2 = physical disk
Detailed Description
A user aborted an ongoing copyback operation. The operation did not complete.
Recommended Response Action
Re-issue the command.
Category
Storage (PDR = Physical Disk)
Severity
Severity 3 (Informational)
Trap/EventID
4347
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*          

PDR8

Message
arg1 is inserted.
Arguments
arg1 = PD Name
Detailed Description
This alert is provided for informational purposes.
Recommended Response Action
No response action is required.
Category
Storage (PDR = Physical Disk)
Severity
Severity 3 (Informational)
Trap/EventID
4347
OMSA Event ID
2052
OMSA Trap ID
90100
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*          

PDR81

Message
Microcode update started on arg1 .
Arguments
arg1 = physical disk
Detailed Description
The physical disk firmware update operation has started.
Recommended Response Action
No response action is required.
Category
Storage (PDR = Physical Disk)
Severity
Severity 3 (Informational)
Trap/EventID
4347
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*          

PDR82

Message
arg1 security was activated.
Arguments
arg1 = physical disk
Detailed Description
Security on a secure encrypted disk was activated.
Recommended Response Action
No response action is required.
Category
Storage (PDR = Physical Disk)
Severity
Severity 3 (Informational)
Trap/EventID
4347
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*          

PDR83

Message
arg1 is reprovisioned.
Arguments
arg1 = PD Name
Detailed Description
This alert is provided for informational purposes.
Recommended Response Action
No response action is required.
Category
Storage (PDR = Physical Disk)
Severity
Severity 3 (Informational)
Trap/EventID
4347
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC      
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*          

PDR84

Message
arg1 Security key has changed.
Arguments
arg1 = physical disk
Detailed Description
The Security key on a secure encrypted disk was activated.
Recommended Response Action
No response action is required.
Category
Storage (PDR = Physical Disk)
Severity
Severity 3 (Informational)
Trap/EventID
4347
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*          

PDR85

Message
Security subsystem errors detected for arg1 .
Arguments
arg1 = physical disk
Detailed Description
Errors were detected with security related operations on the disk. The data on the disk might not be retrieved or stored successfully. In addition, the security of the stored data might be at risk.
Recommended Response Action
Verify the disk is a Secure Encrypted Disk and is not locked. If it is not, replace the disk with a Secure Encrypted Disk. See the storage hardware documentation for more information.
Category
Storage (PDR = Physical Disk)
Severity
Severity 1 (Critical)
Trap/EventID
4345
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*          

PDR86

Message
Bad block table on arg1 is full.
Arguments
arg1 = physical disk
Detailed Description
The number of blocks on the disk that exhibit an error has exceeded the capacity of the drive to remap. Any future writes to bad sectors will be unrecoverable.
Recommended Response Action
Replace the disk.
Category
Storage (PDR = Physical Disk)
Severity
Severity 2 (Warning)
Trap/EventID
4346
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*          

PDR87

Message
arg1 was reset.
Arguments
arg1 = physical device
Detailed Description
The physical device was reset. This is a normal part of operations and is not a cause for concern.
Recommended Response Action
No response action is required.
Category
Storage (PDR = Physical Disk)
Severity
Severity 3 (Informational)
Trap/EventID
4347
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*          

PDR88

Message
Power state change failed on arg1 . (from arg2 to arg3 )
Arguments
arg1 = PD Name, arg2 = state, arg3 = state
Detailed Description
When physical drives in spun down power state are configured, the drives should transition to spun up power state.. If the drive is not functioning properly, this transition could fail.
Recommended Response Action
Replace the physical disk and try again. Contact technical support if the issue persists.
Category
Storage (PDR = Physical Disk)
Severity
Severity 1 (Critical)
Trap/EventID
4345
OMSA Event ID
2402
OMSA Trap ID
90400
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*          

PDR9

Message
Initialization has started on arg1 .
Arguments
arg1 = physical disk
Detailed Description
This alert is provided for informational purposes.
Recommended Response Action
No response action is required.
Category
Storage (PDR = Physical Disk)
Severity
Severity 3 (Informational)
Trap/EventID
4347
OMSA Event ID
2062
OMSA Trap ID
90100
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*          

PDR9000

Message
Foreign Configuration was detected on arg1 .
Arguments
arg1 = physical disk drive name
Detailed Description
Internal Use Only.
Recommended Response Action
Internal Use Only.
Category
Storage (PDR = Physical Disk)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC            
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC   ✔*          

PDR93

Message
Microcode update on arg1 has completed.
Arguments
arg1 = physical disk
Detailed Description
The physical disk firmware update operation has completed.
Recommended Response Action
No response action is required.
Category
Storage (PDR = Physical Disk)
Severity
Severity 3 (Informational)
Trap/EventID
4347
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*          

PDR94

Message
Microcode update on arg1 has timed out.
Arguments
arg1 = physical disk
Detailed Description
The attempt to update the physical disk has timed out. This may be due to too much activity on the bus, a bad update package, or a bad disk.
Recommended Response Action
Retry the update. The update utility may have already performed the retry operation.
Category
Storage (PDR = Physical Disk)
Severity
Severity 3 (Informational)
Trap/EventID
4347
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*          

PDR95

Message
Microcode update on arg1 has failed.
Arguments
arg1 = physical disk
Detailed Description
The attempt to update the physical disk has failed. This is due to too much activity on the bus, a bad update package, or a bad disk.
Recommended Response Action
Retry the update. If the update fails a second time, verify the update package is valid. If the update package is valid, replace the failing disk. Contact technical support if the problem persists.
Category
Storage (PDR = Physical Disk)
Severity
Severity 2 (Warning)
Trap/EventID
4346
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*          

PDR96

Message
Security was disabled on arg1 .
Arguments
arg1 = physical disk
Detailed Description
Security on a secure encrypted disk was disabled.
Recommended Response Action
No response action is required.
Category
Storage (PDR = Physical Disk)
Severity
Severity 3 (Informational)
Trap/EventID
4347
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*          

PDR97

Message
arg1 security key required.
Arguments
arg1 = physical disk
Detailed Description
The controller detected drives that require security keys for access. Without providing security keys, the drives are unstable.
Recommended Response Action
Provide the security key required to unlock the secure encrypted drives.
Category
Storage (PDR = Physical Disk)
Severity
Severity 3 (Informational)
Trap/EventID
4347
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*          

PDR98

Message
Command timeout occurred on arg1 . arg2 .
Arguments
arg1 = physical disk, arg2 = args
Detailed Description
An error occurred while performing an action on the disk.
Recommended Response Action
Check the disk is present or replace the disk.
Category
Storage (PDR = Physical Disk)
Severity
Severity 2 (Warning)
Trap/EventID
4346
OMSA Event ID
2405
OMSA Trap ID
90300
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC      
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*          

Rate this content

Accurate
Useful
Easy to understand
Was this article helpful?
0/3000 characters
  Please provide ratings (1-5 stars).
  Please provide ratings (1-5 stars).
  Please provide ratings (1-5 stars).
  Please select whether the article was helpful or not.
  Comments cannot contain these special characters: <>()\