SSD1001

Message
Write-cache on arg1 is enabled.
Arguments
arg1 = PCIe SSD name
Detailed Description
Write-cache is enabled on the PCIe solid state drive (SSD) identified in the message.
Recommended Response Action
No response action is required.
Category
Storage (SSD = PCIe SSD)
Severity
Severity 2 (Warning)
OMSA Event ID
2427
OMSA Trap ID
90300
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC        
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC            
CMC              

SSD1002

Message
Write-cache on arg1 is disabled.
Arguments
arg1 = PCIe SSD name
Detailed Description
Write-cache is disabled on the PCIe solid state drive (SSD) identified in the message.
Recommended Response Action
No response action is required.
Category
Storage (SSD = PCIe SSD)
Severity
Severity 2 (Warning)
OMSA Event ID
2428
OMSA Trap ID
90300
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC        
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC            
CMC              

SSD1003

Message
arg1 is ready for removal.
Arguments
arg1 = PCIe SSD name
Detailed Description
The PCIe solid state drive (SSD) identified in the message is ready for removal.
Recommended Response Action
No response action is required.
Category
Storage (SSD = PCIe SSD)
Severity
Severity 3 (Informational)
OMSA Event ID
2429
OMSA Trap ID
90100
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC        
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC            
CMC              

SSD1004

Message
Exported the arg1 log file.
Arguments
arg1 = PCIe SSD name
Detailed Description
The log file of the PCIe solid state drive (SSD) identified in the message is successfully exported.
Recommended Response Action
No response action is required.
Category
Storage (SSD = PCIe SSD)
Severity
Severity 3 (Informational)
OMSA Event ID
2430
OMSA Trap ID
90100
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC        
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC            
CMC              

SSD1005

Message
Successfully initialized arg1 .
Arguments
arg1 = PCIe SSD name
Detailed Description
The initialization of the PCIe solid state drive (SSD) identified in the message is complete.
Recommended Response Action
No response action is required.
Category
Storage (SSD = PCIe SSD)
Severity
Severity 3 (Informational)
OMSA Event ID
2431
OMSA Trap ID
90100
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC        
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC            
CMC              

SSD1006

Message
The arg1 has reached arg2 of warranted device wear-out limit.
Arguments
arg1 = PCIe solid state device name, arg2 = percent
Detailed Description
The PCIe solid state device identified in the message is approaching the warranted wear-out limit.
Recommended Response Action
No response action is required.
Category
Storage (SSD = PCIe SSD)
Severity
Severity 3 (Informational)
OMSA Event ID
2433
OMSA Trap ID
90100
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC        
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC            
CMC              

SSD1007

Message
The arg1 has reached or exceeded its warranted wear-out limit.
Arguments
arg1 = PCIe solid state device name
Detailed Description
The PCIe solid state device identified in the message has either reached or exceeded the warranted wear-out limit.
Recommended Response Action
Back up the data on the device, and contact your service provider for further instructions.
Category
Storage (SSD = PCIe SSD)
Severity
Severity 2 (Warning)
OMSA Event ID
2434
OMSA Trap ID
90300
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC        
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC            
CMC              

SSD1008

Message
The arg1 is approaching read-only mode.
Arguments
arg1 = PCIe solid state device name
Detailed Description
The PCIe solid state device identified in the message is between 90% and 100% of reaching read-only mode.
Recommended Response Action
No response action is required.
Category
Storage (SSD = PCIe SSD)
Severity
Severity 3 (Informational)
OMSA Event ID
2435
OMSA Trap ID
90100
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC        
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC            
CMC              

SSD1009

Message
The arg1 is in read-only mode.
Arguments
arg1 = PCIe solid state device name
Detailed Description
The PCIe solid state device identified in the message is in read-only mode.
Recommended Response Action
Back up the data on the device, and contact your service provider for further instructions.
Category
Storage (SSD = PCIe SSD)
Severity
Severity 1 (Critical)
OMSA Event ID
2436
OMSA Trap ID
90400
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC        
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC            
CMC              

SSD1010

Message
The arg1 is in a security locked state.
Arguments
arg1 = PCIe solid state device name
Detailed Description
The PCIe solid state device identified in the message is in a locked state, because an existing initialization task was interrupted due to a power failure or disk removal.
Recommended Response Action
Run Full Initialize operation on the device identified in the message.
Category
Storage (SSD = PCIe SSD)
Severity
Severity 2 (Warning)
OMSA Event ID
2432
OMSA Trap ID
90200
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC        
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC            
CMC              

Rate this content

Accurate
Useful
Easy to understand
Was this article helpful?
0/3000 characters
  Please provide ratings (1-5 stars).
  Please provide ratings (1-5 stars).
  Please provide ratings (1-5 stars).
  Please select whether the article was helpful or not.
  Comments cannot contain these special characters: <>()\