SEL Event Messages

SEL0002

Message
Logging is disabled.
Detailed Description
This message appears when event logging of a specific type is disabled by the user. (IPMI sensor type code 10h - offset 01h)
Recommended Response Action
If unintended, re-enable logging.
Category
System Health (SEL = Sys Event Log)
Severity
Severity 1 (Critical)
Trap/EventID
2377
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC      
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*           ✔*

SEL0003

Message
Logging is enabled.
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health (SEL = Sys Event Log)
Severity
Severity 3 (Informational)
Trap/EventID
2379
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC      
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*           ✔*

SEL0004

Message
Log cleared.
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health (SEL = Sys Event Log)
Severity
Severity 3 (Informational)
Trap/EventID
2379
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC ✔*  
CMC      
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*           ✔*

SEL0006

Message
All event logging is disabled.
Detailed Description
This message appears when all event logging has been disabled by the user. (IPMI sensor type code 10h - offset 03h)
Recommended Response Action
If unintended, re-enable logging.
Category
System Health (SEL = Sys Event Log)
Severity
Severity 1 (Critical)
Trap/EventID
2377
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC      
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*           ✔*

SEL0007

Message
All event logging is enabled.
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health (SEL = Sys Event Log)
Severity
Severity 3 (Informational)
Trap/EventID
2379
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC      
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*           ✔*

SEL0008

Message
System event log (SEL) is full.
Detailed Description
When the event log is full, additional events are not written to the log; or older events will be overwritten and lost. This message may also appear if the user disabled event logging. (IPMI sensor type code 10h - offset 04h)
Recommended Response Action
Backup and clear log.
Category
System Health (SEL = Sys Event Log)
Severity
Severity 1 (Critical)
Trap/EventID
2377
LCD Message
SEL is full. Review & clear log
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC ✔*  
CMC      
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*    
CMC ✔*           ✔*

SEL0010

Message
System event log (SEL) is almost full.
Detailed Description
When the event log is full, additional events are not written to the log or older events will be overwritten and lost. (IPMI sensor type code 10h - offset 05h)
Recommended Response Action
Backup and clear log at the next maintained time.
Category
System Health (SEL = Sys Event Log)
Severity
Severity 2 (Warning)
Trap/EventID
2378
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC      
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*           ✔*

SEL0012

Message
Could not create or initialize the system event log.
Detailed Description
if the system event log failed to initialize platform status and failure events are not captured. Some management software will not report platform exceptions.
Recommended Response Action
Reboot the management controller or iDRAC. Cycle system input power. If problem persists call support.
Category
System Health (SEL = Sys Event Log)
Severity
Severity 1 (Critical)
Trap/EventID
2377
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC      
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*           ✔*

SEL0013

Message
The system event log was created or initialized successfully.
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health (SEL = Sys Event Log)
Severity
Severity 3 (Informational)
Trap/EventID
2379
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC      
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*           ✔*

SEL0014

Message
The System Event Log (SEL) was cleared by arg1 from arg2 .
Arguments
arg1 = username, arg2 = IP address
Detailed Description
The System Event Log (SEL) was cleared by the username identified in the message from the IP address identified in the message.
Recommended Response Action
No response action is required.
Category
System Health (SEL = Sys Event Log)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC        
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC              

SEL1200

Message
The system was reconfigured.
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health (SEL = Sys Event Log)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

SEL1202

Message
OEM system boot.
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health (SEL = Sys Event Log)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

SEL1204

Message
An unknown system hardware failure detected.
Detailed Description
The operating system or BIOS detected an unknown event. (IPMI sensor type code 12h - offset 02h)
Recommended Response Action
Reduce system to minimum supported configuration. If issues persists, contact support.
Category
System Health (SEL = Sys Event Log)
Severity
Severity 1 (Critical)
Trap/EventID
2377
LCD Message
Unknown system hardware failure. Contact support
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC              

SEL1205

Message
The unknown system hardware failure was corrected.
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health (SEL = Sys Event Log)
Severity
Severity 3 (Informational)
Trap/EventID
2379
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC              

SEL1206

Message
An entry was added to auxiliary log.
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health (SEL = Sys Event Log)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

SEL1207

Message
An entry was removed from auxiliary log.
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health (SEL = Sys Event Log)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

SEL1208

Message
A platform event filter action was executed.
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health (SEL = Sys Event Log)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

SEL1209

Message
The platform event filter action failed.
Detailed Description
System policies or permissions may prevent the action from executing. If configured, the system will not execute the action on a platform event (power down, cycle, interrupt, send alert).
Recommended Response Action
Review platform event configuration.
Category
System Health (SEL = Sys Event Log)
Severity
Severity 1 (Critical)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

SEL1210

Message
The time-stamp clock is synchronized.
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health (SEL = Sys Event Log)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

SEL1211

Message
The time-stamp clock could not be synchronized.
Detailed Description
The time stamp on system event log events may not correlate to the system time. (IPMI sensor type code 12h - offset 05h)
Recommended Response Action
Cycle system input power, if problem persists call support.
Category
System Health (SEL = Sys Event Log)
Severity
Severity 1 (Critical)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

SEL1300

Message
No bootable media found.
Detailed Description
System setup displays the system boot order. The local video screen may also show additional information. (IPMI sensor type code 1eh - offset 00h)
Recommended Response Action
Check system boot settings. Check mass storage controller configuration settings is applicable.
Category
System Health (SEL = Sys Event Log)
Severity
Severity 1 (Critical)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

SEL1301

Message
Bootable media found.
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health (SEL = Sys Event Log)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

SEL1302

Message
Non-bootable diskette detected.
Detailed Description
The disk in the drive is not formatted correctly or does not contain the necessary operating system files(IPMI sensor type code 1eh - offset 01h)
Recommended Response Action
Replace diskette with bootable disk.
Category
System Health (SEL = Sys Event Log)
Severity
Severity 1 (Critical)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

SEL1303

Message
Bootable diskette detected.
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health (SEL = Sys Event Log)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

SEL1304

Message
The PXE server not found.
Detailed Description
PXE is one way to boot a system from the network. (IPMI sensor type code 1eh - offset 02h)
Recommended Response Action
Check network and PXE server configuration.
Category
System Health (SEL = Sys Event Log)
Severity
Severity 1 (Critical)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

SEL1305

Message
The PXE server found.
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health (SEL = Sys Event Log)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

SEL1306

Message
Invalid boot sector found.
Detailed Description
The disk in the drive is not formatted correctly or does not contain the necessary operating system files (IPMI sensor type code 1eh - offset 03h)
Recommended Response Action
Replace diskette with bootable disk.
Category
System Health (SEL = Sys Event Log)
Severity
Severity 1 (Critical)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

SEL1307

Message
Boot sector found.
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health (SEL = Sys Event Log)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

SEL1308

Message
A time-out occurred while waiting for user to select a boot source.
Detailed Description
The system has failed to boot to an operating system and needs the user to select a boot source. (IPMI sensor type code 1eh - offset 04h)
Recommended Response Action
Select boot source within the time allowed.
Category
System Health (SEL = Sys Event Log)
Severity
Severity 1 (Critical)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

SEL1309

Message
User selected a boot source.
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health (SEL = Sys Event Log)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

SEL1400

Message
The platform generated a page alert.
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health (SEL = Sys Event Log)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

SEL1402

Message
The platform generated a LAN alert.
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health (SEL = Sys Event Log)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

SEL1404

Message
A platform event trap (PET) was generated.
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health (SEL = Sys Event Log)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

SEL1406

Message
The platform generated a SNMP trap.
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health (SEL = Sys Event Log)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

SEL1500

Message
The chassis management controller (CMC) is redundant.
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health (SEL = Sys Event Log)
Severity
Severity 3 (Informational)
Trap/EventID
2379
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC      
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*           ✔*

SEL1501

Message
Chassis management controller (CMC) redundancy is lost.
Detailed Description
An action or failure has taken place that breaks CMC redundancy. This includes loss of network connection, hardware failures, firmware update, firmware mismatch between CMCs, CMC reset, and unplugging a CMC.
Recommended Response Action
Check CMC network cables and network connections. Check that CMC firmware versions match.
Category
System Health (SEL = Sys Event Log)
Severity
Severity 1 (Critical)
Trap/EventID
2377
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC      
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*           ✔*

SEL1502

Message
Chassis management controller (CMC) redundancy is degraded.
Detailed Description
An action or failure has taken place that degrades CMC redundancy. This includes firmware mismatch between CMCs and a CMC missing SD card.
Recommended Response Action
Chassis management controller (CMC) redundancy is degraded.
Category
System Health (SEL = Sys Event Log)
Severity
Severity 2 (Warning)
Trap/EventID
2378
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC      
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*           ✔*

SEL1503

Message
The chassis management controller (CMC) is not redundant.
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health (SEL = Sys Event Log)
Severity
Severity 3 (Informational)
Trap/EventID
2379
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC      
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*           ✔*

SEL1504

Message
The chassis management controller (CMC) is not redundant. Insufficient resources to maintain normal operations.
Detailed Description
There is not enough available power for two CMCs to operate.
Recommended Response Action
Check overall power consumption and power status.
Category
System Health (SEL = Sys Event Log)
Severity
Severity 1 (Critical)
Trap/EventID
2377
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC      
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*           ✔*

SEL1506

Message
Lost communications with Chassis Group Member arg1 .
Arguments
arg1 = number
Detailed Description
The primary CMC has lost communication with the indicated member CMC.
Recommended Response Action
Check network cable and network connections.
Category
System Health (SEL = Sys Event Log)
Severity
Severity 2 (Warning)
Trap/EventID
2378
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC      
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*           ✔*

SEL1507

Message
Communications restored with Chassis Group Member arg1 .
Arguments
arg1 = number
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health (SEL = Sys Event Log)
Severity
Severity 3 (Informational)
Trap/EventID
2379
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC      
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*           ✔*

SEL1508

Message
Member arg1 could not join the Chassis Group.
Arguments
arg1 = number
Detailed Description
The indicated member may be a member of another chassis group or may be incompatible with membership.
Recommended Response Action
1)Check that the Name or IP address, User Name, and Password of the member are correct. 2)Check that the member is not a leader or member of another group. 3)Check that the member can be reached by the leader.
Category
System Health (SEL = Sys Event Log)
Severity
Severity 2 (Warning)
Trap/EventID
2378
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC      
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*           ✔*

SEL1509

Message
Member arg1 has joined the Chassis Group.
Arguments
arg1 = number
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health (SEL = Sys Event Log)
Severity
Severity 3 (Informational)
Trap/EventID
2379
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC      
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*           ✔*

SEL1510

Message
An authentication error detected for Chassis Group Member arg1 .
Arguments
arg1 = number
Detailed Description
Group master CMC could not log into the group member CMC.
Recommended Response Action
Check login credentials of CMC
Category
System Health (SEL = Sys Event Log)
Severity
Severity 2 (Warning)
Trap/EventID
2378
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC      
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*           ✔*

SEL1511

Message
Member arg1 removed from the Chassis Group.
Arguments
arg1 = number
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health (SEL = Sys Event Log)
Severity
Severity 3 (Informational)
Trap/EventID
2379
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC      
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*           ✔*

SEL9900

Message
An unsupported event occurred.
Detailed Description
The current software version cannot decode this event. The source of the event may come from a source that is not compatible with this software or the event may have been added after the release of this software. You may need to review this event using a tool which displays raw data such as Ipmitool with the -vvv option or Racadm with the -E option.
Recommended Response Action
Upgrade Management Software
Category
System Health (SEL = Sys Event Log)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

SEL9901

Message
OEM software event.
Detailed Description
The current software version cannot decode this event. The source of the event may come from a source that is not compatible with this software or the event may have been added after the release of this software. You may need to review this event using a tool which displays raw data such as Ipmitool with the -vvv option or Racadm with the -E option.
Recommended Response Action
See product documentation for additional information
Category
System Health (SEL = Sys Event Log)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

SEL9902

Message
System software event.
Detailed Description
Software on the system has logged an event that cannot be determined. You may need to review this event using a tool which displays raw data such as Ipmitool with the -vvv option or Racadm with the -E option.
Recommended Response Action
No response action is required.
Category
System Health (SEL = Sys Event Log)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

Rate this content

Accurate
Useful
Easy to understand
Was this article helpful?
0/3000 characters
  Please provide ratings (1-5 stars).
  Please provide ratings (1-5 stars).
  Please provide ratings (1-5 stars).
  Please select whether the article was helpful or not.
  Comments cannot contain these special characters: <>()\