Dell EMC PowerVault MD 34XX/38XX Series Storage Arrays Administrator's Guide

Manually adding SATP rule in ESXi 5.x

To manually add the SATP rule in ESXi 5.x:
  1. Run the following command: # esxcli storage nmp satp rule add –s VMW_SATP_ALUA –V DELL –M array_PID -c tpgs_on
    Where, array_PID is your storage array model/product ID. To select the appropriate array_PID for your storage array, see the following table.
    Table 1. Array pids of different storage arraysMD3400, MD3420, and MD3460 storage arrays have MD34xx array_PID. MD3800i, MD3820i, and MD3860i storage arrays have MD38xxi array_PID. MD3800f, MD3820f, and MD3860f storage arrays have MD38xxf array_PID.
    Storage Array array_PID
    MD3400 MD34xx
    MD3420 MD34xx
    MD3800i MD38xxi
    MD3820i MD38xxi
    MD3800f MD38xxf
    MD3820f MD38xxf
    MD3460 MD34xx
    MD3860i MD38xxi
    MD3860f MD38xxf
  2. Reboot your ESX-based host server.