Removing an FCM:
Identify the fan cooling (FCM) module to be removed.
Push the release latch down and hold it in place (detail No.1).
With your other hand, grasp the handle and pull the FCM outward (detail No.2).
While supporting the FCM with both hands, remove it from the enclosure.
NOTE:The FCM slot must not be empty for more than 2 minutes while the enclosure is powered.
Installing an FCM:
Orient the FCM for insertion into the target slot on the enclosure rear panel, as shown in Figure 2.
Slide the FCM into the slot until the latch clicks home.
The enclosure should automatically detect and make use of the new module.
Wait for the Module OK LED on the newly inserted FCM to illuminate green. See Figure 2.
If the Module OK LED does not illuminate, verify that the FCM is properly inserted and seated in the slot.
If properly seated, the module may be defective. Check the PowerVault Manager and the event logs for more information.
Using the management interfaces (the PowerVault Manager or CLI), determine if the health of the new FCM is OK. Verify that the Module OK LED is green, and that the Ops panel states show no amber module faults.
If replacing multiple FCMs, repeat steps 1 through 4.