Dell Micro Form Factor Computer Shuts Down When Swapping Power Source

Samenvatting: When switching between AC and Type-C adapter power source, the Dell Micro Form Factor computer shuts down. This occurs on the Dell Pro Micro Plus QBM1250, Dell Pro Micro Plus XE QBM1250, and OptiPlex 3000 Thin Client. ...

Dit artikel is van toepassing op Dit artikel is niet van toepassing op Dit artikel is niet gebonden aan een specifiek product. Niet alle productversies worden in dit artikel vermeld.

Symptomen

The computer shuts down when switching the power source from AC to a Type-C adapter.

Affected Platforms:

  • Dell Pro Micro Plus QBM1250
  • Dell Pro Micro Plus XE QBM1250
  • OptiPlex 3000 Thin Client

Oorzaak

The computer does not support switching power sources without shutting down power to the computer first. The dual power does not support hot swap and behavior as below.

  1. When the computer is off, the computer is connected both the AC adapter and the Type-C port/dock. When powered on, the AC adapter becomes the main power source.
  2. If the computer is off, either the AC adapter or Type-C port/dock can be connected. Once powered on the first connected source remains the main power supply, even if another source is added later.
  3. Unplugging the primary power source while the computer is on causes it to shut down.

Oplossing

This is an expected behavior of the Dell Micro Form Factor computers.

Getroffen producten

Dell Pro Micro Plus QBM1250, Dell Pro Micro Plus XE QBM1250, OptiPlex 3000 Thin Client
Artikeleigenschappen
Artikelnummer: 000377065
Artikeltype: Solution
Laatst aangepast: 24 mei 2026
Versie:  2
Vind antwoorden op uw vragen via andere Dell gebruikers
Support Services
Controleer of uw apparaat wordt gedekt door Support Services.