Dell Micro Form Factor Computer Shuts Down When Swapping Power Source
Summary: When switching between AC and Type-C adapter power source, the Dell Micro Form Factor computer shuts down. This occurs on the Dell Pro Micro Plus QBM1250, Dell Pro Micro Plus XE QBM1250, and OptiPlex 3000 Thin Client. ...
Αυτό το άρθρο ισχύει για
Αυτό το άρθρο δεν ισχύει για
Αυτό το άρθρο δεν συνδέεται με κάποιο συγκεκριμένο προϊόν.
Δεν προσδιορίζονται όλες οι εκδόσεις προϊόντων σε αυτό το άρθρο.
Symptoms
The computer shuts down when switching the power source from AC to a Type-C adapter.
Affected Platforms:
Dell Pro Micro Plus QBM1250Dell Pro Micro Plus XE QBM1250OptiPlex 3000 Thin Client
Cause
The computer does not support switching power sources without shutting down power to the computer first. The dual power does not support hot swap and behavior as below.
- When the computer is off, the computer is connected both the AC adapter and the Type-C port/dock. When powered on, the AC adapter becomes the main power source.
- If the computer is off, either the AC adapter or Type-C port/dock can be connected. Once powered on the first connected source remains the main power supply, even if another source is added later.
- Unplugging the primary power source while the computer is on causes it to shut down.
Resolution
This is an expected behavior of the Dell Micro Form Factor computers.
Επηρεαζόμενα προϊόντα
Dell Pro Micro Plus QBM1250, Dell Pro Micro Plus XE QBM1250, OptiPlex 3000 Thin ClientΙδιότητες άρθρου
Article Number: 000377065
Article Type: Solution
Τελευταία τροποποίηση: 06 Οκτ 2025