PowerStore: System Health Checks detects if firmware upgrade is required

Summary: System Health Checks detect if a firmware (FW) upgrade is required.

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Instructions

System Health may display the message "Components Firmware needs to be upgraded (KB#000201500)" in one of the following scenarios:

  • Running a System Check using PowerStore Manager (UI) with the Run System Check option:
    Screenshot of Message "Component Firmware needs to be upgraded"

  • Running the System Health Service Script (svc_health_check) using an SSH connection:

    NOTE: Output truncated for illustrative purposes.
    [SVC:service@50V1BW2-B user]$ svc_health_check run -rhc component_stale_fw_check
    Name                          Location Status     Description
    Component Firmware Check      node_a   Failed     Components Firmware needs to be upgraded (KB#000201500)
    Component Firmware Check      node_b   Failed     Components Firmware needs to be upgraded (KB#000201500)

The above message indicates that incompatible firmware (FW) is detected, and a firmware upgrade is required.

If System Health detects this condition, a Non-Disruptive Upgrade (NDU) completes but incorrect FW is installed. Incorrect FW may have various consequences.
NDU and maintenance operations should not be performed until this issue is resolved.

A manual node FW upgrade process is required. Contact Technical Support for assistance. Reference KB # 201500 for expedited attention and resolution.

Known Issue:
The Component Firmware Check may raise a false positive if there are duplicate FW entries.
If System Check for Component Firmware Check fails, then:

  • Ensure that the latest health check package is installed. (Earlier health check packages do not check for duplicate FW entries.). For details on how to perform this, see the Additional Info section of KB 198084 PowerStore: How to use the System Check feature
  • If a new health check package is required, install the new health check package and then retry the system health check. Verify if duplicate FW entries are detected.
  • If the Component Firmware Check continues to fail after determining that there are no duplicate FW entries, contact Technical Support for assistance.

Additional Information

Affected Products

PowerStore
Article Properties
Article Number: 000201500
Article Type: How To
Last Modified: 24 Nov 2025
Version:  9
Find answers to your questions from other Dell users
Support Services
Check if your device is covered by Support Services.