PPMA shows "Error: Unable to add Host." while adding a host running PowerPath for Linux

Summary: PPMA shows "Error: Unable to add Host." while adding a host running PowerPath for Linux.

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Symptoms

New Linux host running PowerPath for Linux added to the environment,

While adding a Linux host running PowerPath for Linux to PPMA, PPMA returns an error: "Error: Unable to add Host."

PowerPath UI showing error message Unable to add host 

Cause

The Management Component is disabled by default on PowerPath for Linux.

Resolution

Enable the Management Component of PowerPath for Linux on the Linux host by following the steps below:

Configuring Management Component on Linux:

The Management Component is included in the PowerPath package. Separate installation is not required. This procedure describes how to configure the Management Component.
 

  1. Enable the Management Component. As root, enter
    #  /sbin/emcp_mond_edit
     
    1. Start the editor. If the emcp_mond.conf file does not exist on the machine, the editor reads the sample configuration.
       
    2. The Management Component is disabled by default. To enable the Management Component service using default configuration parameter values, type 1 and 6 to confirm the changes and save. Then type the number of the option to exit, save, and restart the Management Component.

      It is recommended to use the default configuration parameters.

      To modify the configuration parameters, go to "Modifying Configuration Parameters on Linux and Unix".
       
  2. Verify that emcp_mond is running and that PowerPath Management Component is started.

    # pgrep -xl emcp_mond

    Alternatively, verify the messages log for successful Management Component installation and start.
    # tail /var/log/ messages

    The message log contains messages such as:
    <date time hostname>PowerPath: Management Component: Info: Attempting to start. Version: 5.3.SP1-b044.
    <date time hostname>PowerPath: Management Component: Info: Config parameters valid. Config: port#=9083, heartbeat interval=10 mins, singlePathGkOk=1
    <date time hostname>PowerPath: Management Component: Info: Service started.
     
  3. Verify that the Management Component is installed correctly on the hosts where you have installed the PowerPath Management Component.
    # rpm -qa | grep EMC

    Output such as the following appears:
    EMCpower.MgmtComponent.LINUX-5.3.2.00.00-046
    EMCpower.LINUX-5.3.1.02.00-007

    The output shows that the Management Component package is installed.

Additional Information

Products

PowerPath/VE for VMware
Article Properties
Article Number: 000168398
Article Type: Solution
Last Modified: 17 Feb 2026
Version:  4
Find answers to your questions from other Dell users
Support Services
Check if your device is covered by Support Services.