PowerStore: Node reboot with empty NVMe Enclosure attached
Summary: A software issue can lead to a Node reboot when there is an empty NVMe enclosure attached has been identified.
This article applies to
This article does not apply to
This article is not tied to any specific product.
Not all product versions are identified in this article.
Symptoms
On an appliance with an empty NVMe enclosure an intermittent reboot of either Node can occur.
Cause
Excessive polling of the empty enclosure can lead to a Node reboot.
Resolution
This is addressed in PowerStoreOS v4.1.0.0.
To avoid this issue, do not attach an empty NVMe enclosure to an appliance.
If there is an empty enclosure attached, add a drive to it.
4.1.0.0 release notes reference: MDT-600475
Affected Products
PowerStoreArticle Properties
Article Number: 000224925
Article Type: Solution
Last Modified: 10 Apr 2025
Version: 3