Dell Unity: Windows host using native MPIO unable to see LUNs on depopulated Unity XT 380 (Dell Correctable)
Resumen: Windows hosts using native MPIO are unable to see LUNs on a Unity XT 380/380F with depopulated service processors. This occurs when using the last two ports of the IOModule (port 2 or 3). Or when using the two CNA ports (4 or 5) without an IOModule installed. ...
Este artículo se aplica a:
Este artículo no se aplica a:
Este artículo no está vinculado a ningún producto específico.
En este artículo no se identifican todas las versiones de los productos.
Síntomas
- Windows hosts using native MPIO are unable to see LUNs
- Unity OE 5.2.x
- Unity XT 380 or 380F with depopulated (no onboard Ethernet ports) service processors (SPs)
- Using the last two ports of the IOModule (port 2 or 3) or using the two CNA ports (4 or 5) without an IOModule installed.
- The issue happens on both ISCSI connected and FC connected hosts.
- The issue happens with direct connect hosts and hosts connected through a switch.
- Windows VM with MPIO enabled shows two disks in Disk Management instead of having two connections seen as one disk.
Causa
The Unity XT 380/380F running OE 5.2.x supports the new depopulated storage processors with the onboard Ethernet ports removed.
Windows hosts using native MPIO are unable to see LUNs on a Unity XT 380/380F with depopulated service processors. This occurs when using the last two ports of the IOModule (port 2 or 3). Or when using the two CNA ports (4 or 5) without an IOModule installed.
Windows hosts using native MPIO are unable to see LUNs on a Unity XT 380/380F with depopulated service processors. This occurs when using the last two ports of the IOModule (port 2 or 3). Or when using the two CNA ports (4 or 5) without an IOModule installed.
Resolución
Fix:
Workaround:
- This issue is fixed in Unity OS: 5.3.1.0.5.008
- Hotfixes are also available for Unity OE version 5.2. Contact Dell Technical Support or your Authorized Service Provider and quote this Dell Knowledge Base article ID to obtain those fixes.
Workaround:
- If an IOModule is installed, use CNA ports 4 & 5 and IOModule ports 0 & 1.
- Use PowerPath instead of Windows native MPIO.
- If there is no IOModule installed, CNA ports 4 and 5 do not work for Windows hosts using native MPIO.
Productos afectados
Dell EMC Unity XT 380, Dell EMC Unity XT 380FPropiedades del artículo
Número de artículo: 000212923
Tipo de artículo: Solution
Última modificación: 25 jul 2025
Versión: 11
Encuentra las respuestas que necesitas con la ayuda de otros usuarios de Dell
Servicios de asistencia
Comprueba si tu dispositivo está cubierto por los servicios de asistencia.