MFE zDP: Incorrect RC for the QUERY command. New message EIP0287W/E introduced

概要: Incorrect RC for the QUERY command

この記事は次に適用されます: この記事は次には適用されません: この記事は、特定の製品に関連付けられていません。 すべての製品パージョンがこの記事に記載されているわけではありません。

現象

The QUERY TGT,STATUS,DEVICE command returns RC=0 when one of the PowerMax systems in TGT is offline.   
  
The QUERY VDG command returns RC=0 when the VDG contains devices that have been deleted from the PowerMax system.    

zDP Definition Utility has been updated to set final return code based on the MAX_RC and the warning/error message severity.
                                               
If a device does not exist on a PowerMax system, the device entry in the QUERY output is marked with a '*'.      
A new message will also be issued:                           
EIP0287W/E VDG <vdg_name>, SYMM <gk/symm-serial>, some devices were not found on the controller 

原因

This is due to a software issue.

解決方法

Permanent fix
  • For Mainframe Enablers 8.5, PTF SF85107 has been developed to correct the issue. It is available to download from Dell Online Support.

その他の情報

PTF cover note
 
++PTF(SF85107) REWORK(2021333) .                               
++VER(Z038) FMID(SSCF850)                                      
      PRE(                                                     
          SF85068 SF85084                                       
          )                                                    
   /*                                                          
*------------------------------------------------------------- 
* PROBLEM DESCRIPTION(S):                                       
* ------------------------------------------------------------ 
* PROBLEM FIXED: OPT 590911 585747                             
* USERS AFFECTED: zDP users                                    
* PROBLEM DESCRIPTION: Incorrect RC for the QUERY command      
* DESCRIPTION DETAIL:                                          
*                                                              
* The QUERY TGT,STATUS,DEVICE command returns RC=0 when one    
* of the PowerMax systems in TGT is offline.                    
* The QUERY VDG command returns RC=0 when the VDG contains     
* devices that have been deleted from the PowerMax system.     
*                                                              
* PROBLEM RESOLUTION:                                           
*                                                              
* zDP Definition Utility has been updated to set final return  
* code based on the MAX_RC and the warning/error message       
* severity.                                                     
* If a device doesn't exist on a PowerMax system, the device   
* entry in the QUERY output will be marked with a '*'.         
* A new message will also be issued:                           
* EIP0287W/E VDG <vdg_name>, SYMM <gk/symm-serial>, some       
* devices were not found on the controller                     
*                                                               
*                                                              
* MODULES: EIPINIT                                             
*          EIPMTBL                                             
*                                                               
* ------------------------------------------------------------ 
* SF85107 29 Nov 2021 12:03:35                                 
* ------------------------------------------------------------ 
*  OPT Summary                                                  
*  The following OPTs were addressed by this PTF:              
*                                                              
*    585747  590911                                            
*                                                               
*------------------------------------------------------------- 