MFE zDP: Feil RC for QUERY-kommandoen. Ny melding EIP0287W/E introdusert

概要: Feil RC for QUERY-kommandoen

この記事は次に適用されます: この記事は次には適用されません: この記事は、特定の製品に関連付けられていません。 すべての製品パージョンがこの記事に記載されているわけではありません。

現象

QUERY TGT,STATUS,DEVICE-kommandoen returnerer RC=0 når et av PowerMax-systemene i TGT er frakoblet.   
  
QUERY VDG-kommandoen returnerer RC=0 når VDG inneholder enheter som er slettet fra PowerMax-systemet.    

zDP Definition Utility er oppdatert for å angi endelig returkode basert på MAX_RC og alvorlighetsgraden for advarselen/feilmeldingen.
                                               
Hvis en enhet ikke finnes på et PowerMax-system, vil enhetsoppføringen i QUERY-utdataene bli merket med "*".      
A new message will also be issued:                           
EIP0287W/E VDG , SYMM , some devices were not found on the controller 

原因

Dette skyldes et programvareproblem.

解決方法

Permanent korrigering
  • For mainframe Enablers 8.5 er PTF SF85107 utviklet for å løse problemet. Det er tilgjengelig for nedlasting fra Dells kundestøtte på Internett.

その他の情報

Merknad om PTF-deksel
 
++PTF(SF85107) REWORK(2021333) .                               
++VER(Z038) FMID(SSCF850)                                      
      PRE(                                                     
          SF85068 SF85084                                       
          )                                                    
   /*                                                          
*------------------------------------------------------------- 
* PROBLEM DESCRIPTION(S):                                       
* ------------------------------------------------------------ 
* PROBLEM FIXED: OPT 590911 585747                             
* USERS AFFECTED: zDP users                                    
* PROBLEM DESCRIPTION: Incorrect RC for the QUERY command      
* DESCRIPTION DETAIL:                                          
*                                                              
* The QUERY TGT,STATUS,DEVICE command returns RC=0 when one    
* of the PowerMax systems in TGT is offline.                    
* The QUERY VDG command returns RC=0 when the VDG contains     
* devices that have been deleted from the PowerMax system.     
*                                                              
* PROBLEM RESOLUTION:                                           
*                                                              
* zDP Definition Utility has been updated to set final return  
* code based on the MAX_RC and the warning/error message       
* severity.                                                     
* If a device doesn't exist on a PowerMax system, the device   
* entry in the QUERY output will be marked with a '*'.         
* A new message will also be issued:                           
* EIP0287W/E VDG , SYMM , some       
* devices were not found on the controller                     
*                                                               
*                                                              
* MODULES: EIPINIT                                             
*          EIPMTBL                                             
*                                                               
* ------------------------------------------------------------ 
* SF85107 29 Nov 2021 12:03:35                                 
* ------------------------------------------------------------ 
*  OPT Summary                                                  
*  The following OPTs were addressed by this PTF:              
*                                                              
*    585747  590911                                            
*                                                               
*------------------------------------------------------------- 