SC9000 Series (Dell Compellent) Reference Articles
摘要: SC9000 is a high-end storage system with expansion up to 1024 hard drives by adding enclosures. The SC9000 can be managed using Dell Storage Manager in your SAN environment. This article references topics like turning, drives, manuals, and best practices. ...
本文章適用於
本文章不適用於
本文無關於任何特定產品。
本文未識別所有產品版本。
症狀
Support Library - SC9000 Series (Dell Compellent)

原因
Product Overview:
The SC9000 is massively scalable with up to 1024 total drives and 6PB raw capacity in a single array. All data is managed through the primary storage controller, deployed in redundant pairs. To expand capacity, you can mix and match from any of the five supported expansion enclosures, depending on your specific performance, cost, or density needs.
Options are available for ultradense (84 drives in 5U) and new high-performance 12Gb SAS enclosures. Adding a new enclosure is simple - the new drives can be automatically assimilated into the existing virtualized pool, or set up as their own stand-alone pool. Data-in-place upgrades make it easy to change controllers and other key components, or migrate from legacy SC Series arrays.
解析度
Note: Some documents may only be available in English.
General overview:
- Dell EMC Storage SC9000 Owner's Manuals
- SC9000 Manuals and Documents
- Dell EMC Switch Configuration Guide for Dell EMC Unity, SC Series (Compellent) , PS Series (EqualLogic) for iSCSI SANs
- Dell SC Series (Compellent) Best Practices with VMWare vSphere 5.x to 7.x
- Citrix XenServer with Dell SC Series Storage Configuration and Deployment
Getting Started:
- SC Storage Customer Notification: How to apply Host Server Best Practice settings using the Dell Storage Manager Client
- Dell EMC SC Series Storage and Microsoft Multipath I/O
- Dell EMC SC Series and Active Directory Integration
- Dell SC Series Storage with SAS Front-end Support for VMWare vSphere
- Citrix XenServer with Dell SC Series Storage Cnfiguration and Deployment
- Deploying SharePoint 2016 utilizing Dell Storage SC Series Arrays
- SC Storage Customer Notification: Port Numbering of 25Gb and 100Gb Chelsio iSCSI Mezzanine Adapters Reversed
- SC Series VASA (VMware® vSphere Storage APIs for Storage Awareness) Provider
- Microprocessor Side-Channel Vulnerabilities (CVE-2018-3639 and CVE-2018-3640): Impact on Dell EMC PowerEdge Servers, Storage (SC Series, PS Series, and PowerVault MD Series) and Networking products
Troubleshooting:
- Drivers and Downloads
- SC Storage Customer Notification: Dell Storage Manager server setup fails with Error Turning on MPIO
- SC Storage Customer Notification: SC9000 Reporting Multi-bit Memory Errors When Warm Booting From IDRAC
- SC Storage Customer Notification: Deduplication Operation can result in unexpected system behavior
- SC Storage Customer Notification: Troubleshooting DSM "Error setting up connection" Message During Initial Deployment
- SC Storage Customer Notification: Adjusting Storage Profiles may result in errors while utilizing SCOS 7.1.20, 7.2.11, or 7.2.30 with Deduplication and / or Compression
- SC Storage Customer Notification: Deduplication Operation can result in unexpected system behavior
- SC Storage Customer Notification: Consistency snapshots fail when volume(s) in Recycle Bin
System Software:
- Dell EMC SC Series: Performance and Availability Dell Storage Center OS (SCOS) 7.3
- Storage Center OS Version 7 Command Utility Reference Guide
- SC Storage Customer Notification: Adjusting Storage Profiles may result in errors while utilizing SCOS 7.1.20, 7.2.11, or 7.2.30 with Deduplication and / or Compression
Storage Enclosures:
- For information about Dell EMC SC Series Expansion Enclosures Click here
- Dell SC400, SC420, and SC420F Expansion Enclosure Owner's Manual
- Dell Storage SC460 Owners Manual and Support page
受影響的產品
Dell Storage SC400, Dell Storage SC420, Dell Storage SC420F, Dell Storage SC460, Dell Storage SC9000文章屬性
文章編號: 000178225
文章類型: Solution
上次修改時間: 07 12月 2023
版本: 7
向其他 Dell 使用者尋求您問題的答案
支援服務
檢查您的裝置是否在支援服務的涵蓋範圍內。