SC Storage Customer Notification: SC9000 Reporting Multi-bit Memory Errors When Warm Booting From IDRAC

摘要: This article covers the reporting of multi-bit memory errors in SC9000 systems when warm booting from IDRAC

本文章適用於 本文章不適用於 本文無關於任何特定產品。 本文未識別所有產品版本。

症狀

A memory reporting error will occur when an SC9000 is warm booted via iDRAC.  The error messages can be seen in the System Event Logs (SEL) from the iDRAC and will be similar to the following:
 
MEM0001 Multi-bit memory errors detected on a memory device at location(s) DIMM_XX.
PST0090 A problem was detected related to the previous server boot.
CPU0000 CPU 1 has an internal error (IERR).

The cause of this issue is a known issue reported by Intel where memory errors will occur during a warm reset through the iDRAC (which is not typically done or recommended).  

解析度

Resolution: 
A BIOS update that contains new Intel Memory reference code to address Multi-bit and Single-bit DIMM memory errors during boot is implemented in SCOS 7.3.1 and greater.  In particular, SCOS 7.3.1 and later includes BIOS version 2.5.5 and iDRAC version 2.50.50.50


Workaround:
Reset the controller through Dell Storage Manager (Recommended) and the memory errors will not occur.  